Literature DB >> 2104523

Topography of the retinal thickness in normal subjects.

M Shahidi1, R C Zeimer, M Mori.   

Abstract

A noninvasive method has been developed that is capable of providing quantitative thickness profiles of the retina. The method was used to map the retinal thickness in five normal human volunteers and determine the reproducibility of the measurements. The reproducibility or equivalent sensitivity of the measurements to detect changes was found to be 5% or 19 microns on the same day and 8% or 31 microns on different days. By averaging the values obtained in five normal subjects, ranging in age from 21 to 43 years (mean, 34 years), a preliminary normal baseline was derived for the thickness profile at the fovea and the thickness cross-section from the optic disc to the fovea. The results of the study indicated that this noninvasive method promises to be of clinical use in diagnosing ocular diseases that produce changes in the thickness of the retinal as well as in monitoring the effectiveness of therapy.

Entities:  

Mesh:

Year:  1990        PMID: 2104523     DOI: 10.1016/s0161-6420(90)32457-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  13 in total

1.  Eccentricity and measurement variability and repeatability with the retinal thickness analyser.

Authors:  E D Gilmore; C Hudson
Journal:  Br J Ophthalmol       Date:  2004-01       Impact factor: 4.638

2.  Histological measurement of human retinal thickness.

Authors:  Z Yang; S Du
Journal:  J Tongji Med Univ       Date:  1999

3.  Measurement of retinal thickness in normal subjects with retinal thickness analyzer.

Authors:  Z Yang; S Du
Journal:  J Tongji Med Univ       Date:  1999

4.  Spectrometric investigations in ocular hypertension and early stages of primary open angle glaucoma and of low tension glaucoma--multisubstance analysis.

Authors:  D Schweitzer; S Guenther; M Scibor; M Hammer
Journal:  Int Ophthalmol       Date:  1992-09       Impact factor: 2.031

5.  Quantitative assessment of macular thickness in normal subjects and patients with diabetic retinopathy by scanning retinal thickness analyser.

Authors:  Y Oshima; K Emi; S Yamanishi; M Motokura
Journal:  Br J Ophthalmol       Date:  1999-01       Impact factor: 4.638

6.  A microfabricated scaffold for retinal progenitor cell grafting.

Authors:  William L Neeley; Stephen Redenti; Henry Klassen; Sarah Tao; Tejal Desai; Michael J Young; Robert Langer
Journal:  Biomaterials       Date:  2007-10-24       Impact factor: 12.479

7.  Retinal thickness variation in the diabetic patient measured by the retinal thickness analyser.

Authors:  D Weinberger; R Axer-Siegel; D Landau; Y Yassur
Journal:  Br J Ophthalmol       Date:  1998-09       Impact factor: 4.638

8.  Enhanced detection of normal retinal nerve-fiber striations using a charge-coupled device and digital filtering.

Authors:  D W Richards; J R Janesick; S T Elliot; A Dingizian; R Velthuizen; Q Wei; L P Clarke
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1993-10       Impact factor: 3.117

9.  Clinical evaluation of the optic nerve in glaucoma.

Authors:  J Caprioli
Journal:  Trans Am Ophthalmol Soc       Date:  1994

10.  Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph.

Authors:  H J Zambarakji; J E Evans; W M Amoaku; S A Vernon
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.