Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques.

M Nakata1, T Masuzawa, E Tatsumi, Y Taenaka, T Nishimura, T Tsukiya, H Takano, K Tsuchimoto, K Ohba.   

Abstract

We applied two different flow visualization techniques to obtain detailed information on the inside flow of the diaphragm blood pump of our electrohydraulic total artificial heart system to determine the optimum washout effect that would result in better antithrombogenicity. Major orifice directions of the inflow and outflow Bjork-Shiley valves of the left blood pump were independently changed to create 17 varied patterns. The character and velocity of the main flow at the diaphragm-housing junction were acquired using a laser light sheet method with polyethylene tracers. Wall shear flow, a major factor governing washout in the blood pump, was estimated by a newly developed paint erosion method. In this method, quantitative evaluation for an index of washout effect was made by calculating the residual ratio of the paint on the blood pump inner surface at 30 sec of pumping. When a single circular flow was consistently observed by the laser light sheet method, the paint residual ratio become low, indicating washout was relatively good. At the lowest paint residual ratio, the center of the circular flow observed by the laser light sheet method was located at the geometric center of the blood chamber. In conclusion, the flow pattern inside the blood pump could be characterized by combined use of these two flow visualization techniques, and the significant role of circular flow in better washout was clarified.

Entities:  

Mesh:

Year:  1998        PMID: 9804529     DOI: 10.1097/00002480-199809000-00084

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  6 in total

1.  Flow visualization for different port angles of a pulsatile ventricular assist device.

Authors:  Eiki Akagawa; Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2011-10-30       Impact factor: 1.731

2.  Hemodynamic influence of tilting disc valve type on pump performance with the NIPRO-ventricular assist device.

Authors:  Mitsutoshi Kimura; Takashi Nishimura; Osamu Kinoshita; Koichi Kashiwa; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2011-11-11       Impact factor: 1.731

3.  Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device.

Authors:  Eiki Akagawa; Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Nobumasa Katagiri; Yukihide Kakuta; Tomohiro Nishinaka; Toshihide Mizuno; Kei Ota; Rei Kansaku; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

4.  Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.

Authors:  Hwansung Lee; Yoshiaki Ikeuchi; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka; Takao Yamamoto
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

5.  Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing.

Authors:  Hwansung Lee; Akihiko Homma; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

6.  Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing.

Authors:  Hwansung Lee; Akihiko Homma; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2010-02-13       Impact factor: 1.731

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.