Observation of cavitation pits on mechanical heart valve surfaces in an artificial heart used in in vitro testing.

Hwansung Lee1, Akihiko Homma, Eisuke Tatsumi, Yoshiyuki Taenaka.   

Abstract

Our group has developed an electrohydraulic total artificial heart (EHTAH) with two diaphragm-type blood pumps. Cavitation in a mechanical heart valve (MHV) causes valve surface damage. The objective of this study was to investigate the possibility of estimating the MHV cavitation intensity using the slope of the driving pressure just before valve closure in this artificial heart. Twenty-five and twenty-three-millimeter Medtronic Hall valves were mounted at the inlet and outlet ports, respectively, of both pumps. The EHTAH was connected to the experimental endurance tester developed by our group, and tested under physiological pressure conditions. Cavitation pits could be seen on the inlet valve surface and on the outlet valve surface of the right and left blood pumps. The pits on the inlet valves were more severe than those on the outlet valves in both blood pumps, and the cavitation pits on the inlet valve of the left blood pump were more severe than those on the inlet valve of the right blood pump. The longer the pump running time, the more severe the cavitation pits on the valve surfaces. Cavitation pits were concentrated near the contact area with the valve stop. The major cause of these pits was the squeeze flow between the leaflet and valve stop.

Entities:  

Mesh:

Year:  2010        PMID: 20155293     DOI: 10.1007/s10047-010-0490-3

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  16 in total

1.  In vivo demonstration of cavitation potential of a mechanical heart valve.

Authors:  E U Dexter; S Aluri; R R Radcliffe; H Zhu; D D Carlson; T E Heilman; K B Chandran; W E Richenbacher
Journal:  ASAIO J       Date:  1999 Sep-Oct       Impact factor: 2.872

2.  In vitro studies of gas bubble formation by mechanical heart valves.

Authors:  B A Biancucci; S Deutsch; D B Geselowitz; J M Tarbell
Journal:  J Heart Valve Dis       Date:  1999-03

3.  Cavitation of mechanical heart valves under physiologic conditions.

Authors:  T Graf; H Reul; W Dietz; R Wilmes; G Rau
Journal:  J Heart Valve Dis       Date:  1992-09

4.  Mechanism for cavitation in the mechanical heart valve with an artificial heart: nuclei and viscosity dependence.

Authors:  Hwansung Lee; Yoshiyuki Taenaka; Soichiro Kitamura
Journal:  Artif Organs       Date:  2005-01       Impact factor: 3.094

5.  Observation and quantification of cavitation on a mechanical heart valve with an electro-hydraulic total artificial heart.

Authors:  H Lee; Y Taenaka
Journal:  Int J Artif Organs       Date:  2006-03       Impact factor: 1.595

6.  Observation of cavitation pits on a mechanical heart valve surface in an artificial heart used in in vivo testing.

Authors:  Hwansung Lee; Akihiko Homma; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

7.  In vivo observation of cavitation on prosthetic heart valves.

Authors:  C M Zapanta; D R Stinebring; D S Sneckenberger; S Deutsch; D B Geselowitz; J M Tarbell; A J Synder; G Rosenberg; W J Weiss; W E Pae; W S Pierce
Journal:  ASAIO J       Date:  1996 Sep-Oct       Impact factor: 2.872

8.  Origin and appearance of HITS induced by prosthetic heart valves: an in vitro study.

Authors:  K Potthast; G Erdönmez; C Schnelke; L Sellin; U Sliwka; F Schöndube; M Eichler; H Reul
Journal:  Int J Artif Organs       Date:  2000-07       Impact factor: 1.595

9.  Observation and quantification of gas bubble formation on a mechanical heart valve.

Authors:  H Y Lin; B A Bianccucci; S Deutsch; A A Fontaine; J M Tarbell
Journal:  J Biomech Eng       Date:  2000-08       Impact factor: 2.097

10.  Strut fracture with Björk-Shiley 70 degrees convexo-concave valve. An international multi-institutional follow-up study.

Authors:  A Ericsson; D Lindblom; G Semb; H A Huysmans; L I Thulin; H E Scully; J G Bennett; J Ostermeyer; G L Grunkemeier
Journal:  Eur J Cardiothorac Surg       Date:  1992       Impact factor: 4.191

View more
  2 in total

1.  Localized removal of layers of metal, polymer, or biomaterial by ultrasound cavitation bubbles.

Authors:  David Fernandez Rivas; Bram Verhaagen; James R T Seddon; Aaldert G Zijlstra; Lei-Meng Jiang; Luc W M van der Sluis; Michel Versluis; Detlef Lohse; Han J G E Gardeniers
Journal:  Biomicrofluidics       Date:  2012-08-21       Impact factor: 2.800

Review 2.  Journal of Artificial Organs 2010: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2011-03-16       Impact factor: 1.731

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.