Literature DB >> 9800695

Optimization of the scintillation detector in a combined 3D megavoltage CT scanner and portal imager.

M A Mosleh-Shirazi1, W Swindell, P M Evans.   

Abstract

A parametric study is described leading to the optimization of a custom-made scintillation detector with a relatively high quantum efficiency (QE) for megavoltage photons and light output toward a remote lens. This detector allows low-dose portal imaging and continuous cone-beam megavoltage CT acquisition. The EGS4 Monte Carlo code was used to simulate the x-ray and electron transport in the detector. A Monte Carlo model of optical photon transport in a detector element was devised and used as well as various irradiation experiments on scintillators. Different detector materials and configurations were compared in terms of the optical photon irradiance on the lens from on- and off-axis detector elements and the practical constraints regarding detector construction and weight. Effects of scintillator material, detector element size, crystal coating type, and reflectivity, combinations of different coatings on detector faces, scintillator doping level, and crystal transparency were studied. With scintillator thickness adjusted to give an 18% x-ray QE at 6 MV, the light output of CsI(Tl) was at least eight times higher than ZnWO4, BGO and NE118 plastic. Further, CsI(Tl) showed the smallest decrease in QE going from 6 to 24 MV. The off-axis reduction in emittance from the periphery of the detector was relatively small with a slight dependence on the type and reflectivity of the coating and the crystal thickness for a fixed detector element cross section. Light output was more strongly dependent on the reflectivity of lambertian coatings than specular ones. For a fixed detector element cross section, optimum coating type depended on crystal thickness. Typical CsI(Tl) crystals showed a relatively small variation in light output with changes in optical attenuation length. The optimum detector element was found to be CsI(Tl) coated on five faces with TiO2-loaded epoxy resin offering about a ten-fold improvement in light output per incident photon compared to typical metal/phosphor screens.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9800695     DOI: 10.1118/1.598377

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  15 in total

1.  Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging.

Authors:  Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Yi Wang; Hong Du; Amit Sawant; Zhong Su; Jin Yamamoto
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Monte Carlo investigations of megavoltage cone-beam CT using thick, segmented scintillating detectors for soft tissue visualization.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Amit Sawant; Hong Du
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

Review 4.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

5.  A Monte Carlo investigation of Swank noise for thick, segmented, crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

6.  Experimental validation of Monte Carlo (MANTIS) simulated x-ray response of columnar CsI scintillator screens.

Authors:  Melanie Freed; Stuart Miller; Katherine Tang; Aldo Badano
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

7.  Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Youcef El-Mohri; Larry E Antonuk; Qihua Zhao
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

8.  A Monte Carlo study of the impact of phosphor optical properties on EPID imaging performance.

Authors:  Mengying Shi; Marios Myronakis; Yue-Houng Hu; Daniel Morf; Joerg Rottmann; Ross Berbeco
Journal:  Phys Med Biol       Date:  2018-08-20       Impact factor: 3.609

9.  Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Authors:  Youcef El-Mohri; Larry E Antonuk; Richard B Choroszucha; Qihua Zhao; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

10.  A novel multilayer MV imager computational model for component optimization.

Authors:  Marios Myronakis; Josh Star-Lack; Paul Baturin; Joerg Rottmann; Daniel Morf; Adam Wang; Yue-Houng Hu; Daniel Shedlock; Ross I Berbeco
Journal:  Med Phys       Date:  2017-06-28       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.