Literature DB >> 9797663

Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea.

A Azuara-Blanco1, T K Bhojani, A R Sarhan, C T Pillai, H S Dua.   

Abstract

AIMS: To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas.
METHODS: 15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tono-Pen readings of IOP were obtained sequentially from the affected and non-affected corneal surface. Additionally, Goldmann applanation tonometry was attempted.
RESULTS: Determination of IOP with the Tono-Pen was possible in all cases, while Goldmann tonometry was not performed in three patients because of severe corneal irregularities. The average of the Tono-Pen readings obtained from the affected cornea (34.8 (SD 14.0) mm Hg) was consistently and significantly higher (p < 0.001) than mean IOP obtained by the Tono-Pen from the non-affected area (14.8 (4.3) mm Hg). The average of Goldmann tonometry readings (14.4 (6.1) mm Hg) did not differ significantly from the Tono-Pen values obtained from the non-affected corneal area (p = 0.47) but was significantly lower than the Tono-Pen measurements obtained from the affected area (p < 0.001).
CONCLUSION: In patients with band keratopathy or glued corneas determination of IOP by Tono-Pen tonometry varies from affected to non-affected area. The Tono-Pen overestimates the level of IOP when it is applied to areas with band keratopathy or with glue.

Entities:  

Mesh:

Year:  1998        PMID: 9797663      PMCID: PMC1722648          DOI: 10.1136/bjo.82.6.634

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  14 in total

1.  Tono-Pen tonometry in normal and in post-keratoplasty eyes.

Authors:  O Geyer; Y Mayron; A Loewenstein; M Neudorfer; L Rothkoff; M Lazar
Journal:  Br J Ophthalmol       Date:  1992-09       Impact factor: 4.638

2.  The Goldmann applanation tonometer.

Authors:  R A MOSES
Journal:  Am J Ophthalmol       Date:  1958-12       Impact factor: 5.258

3.  Comparison of Oculab Tono-Pen readings obtained from various corneal and scleral locations.

Authors:  J A Khan; M Davis; C E Graham; J Trank; M M Whitacre
Journal:  Arch Ophthalmol       Date:  1991-10

4.  Clinical evaluation of the Oculab Tono-Pen.

Authors:  D S Minckler; G Baerveldt; D K Heuer; B Quillen-Thomas; A F Walonker; J Weiner
Journal:  Am J Ophthalmol       Date:  1987-08-15       Impact factor: 5.258

5.  Measurement of intraocular pressure with a pneumatic applanation tonometer.

Authors:  C E West; J A Capella; H E Kaufman
Journal:  Am J Ophthalmol       Date:  1972-09       Impact factor: 5.258

6.  Validity of Mackay-Marg electronic applanation tonometer in patients with scarred irregular corneas.

Authors:  H E Kaufman; C A Wind; S R Waltman
Journal:  Am J Ophthalmol       Date:  1970-06       Impact factor: 5.258

7.  Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

Authors:  M J Ménage; P L Kaufman; M A Croft; S P Landay
Journal:  Br J Ophthalmol       Date:  1994-09       Impact factor: 4.638

8.  Comparison of MacKay-Marg, Goldmann, and Perkins tonometers in abnormal corneas.

Authors:  F McMillan; R K Forster
Journal:  Arch Ophthalmol       Date:  1975-06

9.  The pneumatonograph. A laboratory study.

Authors:  R A Moses; W J Grodzki
Journal:  Arch Ophthalmol       Date:  1979-03

10.  Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer.

Authors:  S F Kao; P R Lichter; T J Bergstrom; S Rowe; D C Musch
Journal:  Ophthalmology       Date:  1987-12       Impact factor: 12.079

View more
  9 in total

1.  Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma.

Authors:  P Fogagnolo; L Rossetti; F Mazzolani; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

2.  Limbal rebound tonometry: clinical comparisons and applications.

Authors:  Georgios Bontzos; Michail Agiorgiotakis; Zoi Kapsala; Efstathios Detorakis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-28       Impact factor: 3.117

3.  Comparison of intraocular pressures at different points in human's cornea before and after laser in situ keratomileusis with tono-pen tonometer.

Authors:  Xinyu Li; Guigang Li; Lei Liu; Jing Li
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2011-02-19

4.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

5.  Central and peripheral intraocular pressure measured by a rebound tonometer.

Authors:  Tsutomu Yamashita; Atsushi Miki; Yoshiaki Ieki; Junichi Kiryu; Kiyoshi Yaoeda; Motohiro Shirakashi
Journal:  Clin Ophthalmol       Date:  2011-08-10

6.  Detecting IOP Fluctuations in Glaucoma Patients.

Authors:  Brenda Nuyen; Kaweh Mansouri
Journal:  Open Ophthalmol J       Date:  2016-02-29

7.  Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children.

Authors:  Usha Kaul Raina; Neha Rathie; Anika Gupta; Shantanu Kumar Gupta; Meenakshi Thakar
Journal:  Oman J Ophthalmol       Date:  2016 Jan-Apr

8.  Comparisons of the Tono-Pen® and Goldmann Applanation Tonometer in the Measurement of Intraocular Pressure of Primary Open Angle Glaucoma Patients in a Hospital Population in Southwest Nigeria.

Authors:  Chizoba Onochie; Obiekwe Okoye; Adunola Ogunro; Tade Aribaba; Kunle Hassan; Adeola Onakoya
Journal:  Med Princ Pract       Date:  2016-08-09       Impact factor: 1.927

9.  Comparison of Goldmann Applanation, Noncontact Air Puff, and Tono-Pen XL Tonometry in Normal Controls versus Glaucoma Patients at a University Hospital in Riyadh, Saudi Arabia.

Authors:  Essam A Osman; Priscilla W Gikandi; Abdul-Rahman A Al-Jasser; Majeedah Alotaibi; Ahmed Mousa
Journal:  Middle East Afr J Ophthalmol       Date:  2018 Jan-Mar
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.