Literature DB >> 15489480

The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

A C Browning1, A Bhan, A P Rotchford, S Shah, H S Dua.   

Abstract

BACKGROUND/AIM: To compare intraocular pressure (IOP) measurements taken by the Goldmann applanation tonometer, the Tono-Pen and the ocular blood flow pneumotonometer in eyes with varying central corneal thickness (CCT) due to penetrating keratoplasty (PK), keratoconus (KC), and Fuchs' endothelial dystrophy (FED).
METHODS: IOP was measured with the Goldmann applanation tonometer, Tono-Pen XL, and OBF pneumotonometer in 127 eyes with the following corneal abnormalities. There were 56 eyes that had undergone PK, 37 eyes with KC, and 34 eyes with FED. CCT was measured using an ultrasound pachymeter after IOP determinations had been made.
RESULTS: Mean IOP measurements in all three patient groups were significantly higher when measured by OBF pneumotonometer. Linear regression analysis showed that patients with FED had a significant increase in IOP with increasing CCT of 0.18 mm Hg/10 microm using the Goldmann tonometer, 0.15 mm Hg/10 microm with the Tono-Pen, and 0.26 mm Hg/10 microm with the OBF pneumotonometer. In patients with KC and after PK, linear regression analysis did not show a significant effect of CCT on IOP. A multivariate linear regression model controlling for age, sex, graft size, and patient group, showed that the effect of CCT on IOP for Tono-Pen (0.13 mm Hg/10 microm CCT) and Goldmann (0.14 mm Hg/10 microm CCT) were significantly lower than for the OBF pneumotonometer (0.26 mm Hg/10 microm CCT).
CONCLUSIONS: This study found that mean IOP measurements using the OBF pneumotonometer were significantly higher than those made using the Goldmann applanation tonometer or Tono-Pen in eyes with a variety of cornel pathologies. The OBF pneumotonometer was found to be most affected by variation in CCT. For all three instruments, the relation between IOP and CCT depended on the corneal pathology and was greatest for FED.

Entities:  

Mesh:

Year:  2004        PMID: 15489480      PMCID: PMC1772391          DOI: 10.1136/bjo.2003.037887

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  38 in total

1.  Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer.

Authors:  H A Quigley; M E Langham
Journal:  Am J Ophthalmol       Date:  1975-08       Impact factor: 5.258

2.  Applanation tonometry and central corneal thickness.

Authors:  N Ehlers; T Bramsen; S Sperling
Journal:  Acta Ophthalmol (Copenh)       Date:  1975-03

3.  Reliability coefficients of three corneal pachymeters.

Authors:  N C Wheeler; C M Morantes; R M Kristensen; T H Pettit; D A Lee
Journal:  Am J Ophthalmol       Date:  1992-06-15       Impact factor: 5.258

4.  Accuracy and precision of the Tono-Pen in measuring intraocular pressure after keratoplasty and epikeratophakia and in scarred corneas.

Authors:  D S Rootman; M S Insler; H W Thompson; J Parelman; D Poland; S R Unterman
Journal:  Arch Ophthalmol       Date:  1988-12

5.  Effects of central corneal thickness on measurement of intra-ocular pressure in keratoconus and post-keratoplasty.

Authors:  S Patel; J M McLaughlin
Journal:  Ophthalmic Physiol Opt       Date:  1999-05       Impact factor: 3.117

6.  Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic.

Authors:  S Shah; A Chatterjee; M Mathai; S P Kelly; J Kwartz; D Henson; D McLeod
Journal:  Ophthalmology       Date:  1999-11       Impact factor: 12.079

7.  Evaluation and comparison of sources of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters.

Authors:  J J Salz; S P Azen; J Berstein; P Caroline; R A Villasenor; D J Schanzlin
Journal:  Ophthalmic Surg       Date:  1983-09

8.  A guide to pachymeters.

Authors:  S P Thornton
Journal:  Ophthalmic Surg       Date:  1984-12

9.  Incidence of increased intraocular pressure after keratoplasty.

Authors:  D B Goldberg; D J Schanzlin; S I Brown
Journal:  Am J Ophthalmol       Date:  1981-09       Impact factor: 5.258

10.  Automatic tonometer with exact theory: various biological applications.

Authors:  R S MACKAY; E MARG; R OECHSLI
Journal:  Science       Date:  1960-06-03       Impact factor: 47.728

View more
  10 in total

Review 1.  [The risk of glaucoma and corneal thickness].

Authors:  A G Böhm
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

2.  Comparison of IOP measurement using GAT and DCT in patients with penetrating keratoplasties.

Authors:  A R Ismail; M Lamont; S Perera; D Khan-Lim; R Mehta; J D A Macleod; D F Anderson
Journal:  Br J Ophthalmol       Date:  2007-07       Impact factor: 4.638

3.  Limbal rebound tonometry: clinical comparisons and applications.

Authors:  Georgios Bontzos; Michail Agiorgiotakis; Zoi Kapsala; Efstathios Detorakis
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-06-28       Impact factor: 3.117

4.  Age differences in central and peripheral intraocular pressure using a rebound tonometer.

Authors:  J M González-Méijome; J Jorge; A Queirós; P Fernandes; R Montés-Micó; J B Almeida; M A Parafita
Journal:  Br J Ophthalmol       Date:  2006-08-02       Impact factor: 4.638

5.  The influence of corneal geometrical and biomechanical properties on tonometry readings in keratoconic eyes.

Authors:  Mustafa Değer Bilgeç; Eray Atalay; Ömer Sözer; Hüseyin Gürsoy; Muzaffer Bilgin; Nilgün Yıldırım
Journal:  Int Ophthalmol       Date:  2019-12-02       Impact factor: 2.031

Review 6.  Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

Authors:  Emily C Greenlee; Young H Kwon
Journal:  Int Ophthalmol       Date:  2008-06       Impact factor: 2.031

7.  Which tonometry in eyes with keratoconus?

Authors:  H Altinkaynak; C Kocasarac; H Dundar; N Sayin; N Kara; E Bozkurt; N Duru
Journal:  Eye (Lond)       Date:  2015-12-04       Impact factor: 3.775

8.  Purinergic dysregulation causes hypertensive glaucoma-like optic neuropathy.

Authors:  Youichi Shinozaki; Kenji Kashiwagi; Kazuhiko Namekata; Akiko Takeda; Nobuhiko Ohno; Bernard Robaye; Takayuki Harada; Takeshi Iwata; Schuichi Koizumi
Journal:  JCI Insight       Date:  2017-10-05

9.  Analysis of the viscoelastic properties of the human cornea using Scheimpflug imaging in inflation experiment of eye globes.

Authors:  Giuseppe Lombardo; Sebastiano Serrao; Marianna Rosati; Marco Lombardo
Journal:  PLoS One       Date:  2014-11-14       Impact factor: 3.240

Review 10.  Teleglaucoma: ready to go?

Authors:  N G Strouthidis; G Chandrasekharan; J P Diamond; I E Murdoch
Journal:  Br J Ophthalmol       Date:  2014-04-10       Impact factor: 4.638

  10 in total