Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer.

S F Kao1, P R Lichter, T J Bergstrom, S Rowe, D C Musch.   

Abstract

The Oculab Tono-Pen tonometer was compared with the Goldmann applanation tonometer through studies on 197 eyes of 103 patients with glaucoma or ocular hypertension to evaluate the reliability of the Tono-Pen in determining intraocular pressure (IOP). Patients were randomized into four groups and all applanations were done by the same investigator. The Tono-Pen initially used (Tono-Pen #1) failed to calibrate after being used on 77 eyes. Tono-Pen #2 was then obtained and tested. Each Tono-Pen showed high correlation with the Goldmann readings (r greater than or equal to 0.86 in both eyes). The overall sensitivity of the Tono-Pen in detecting IOPs of 21 mmHg or higher (as measured by the Goldmann instrument) was 62.1% in right eyes, 72.4% in left eyes, with corresponding specificities of 92.6% in the right and 97.1% in the left. Given the substantial increase in sensitivity noted with Tono-Pen #2, the Tono-Pen appears adequate for screening programs where an IOP of 21 mmHg or above is considered abnormal; however, at higher IOPs (greater than or equal to 30 mmHg) the Tono-Pens tended to underestimate Goldmann IOPs. At low IOPs (less than or equal to 9 mmHg) the Tono-Pens tended to overestimate the IOPs. Perhaps with further modifications of the instrument, it could be used for clinical diagnosis and management of glaucoma patients.

Entities:  

Mesh:

Year:  1987        PMID: 3431824     DOI: 10.1016/s0161-6420(87)33249-x

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  28 in total

1.  The use of topical aqueous suppressants in the prevention of postoperative intraocular pressure elevation following pars plana vitrectomy with long-acting gas tamponade.

Authors:  R A Mittra; J S Pollack; S Dev; D P Han; W F Mieler; T B Connor
Journal:  Trans Am Ophthalmol Soc       Date:  1998

2.  Measurement of intraocular pressure after epikeratophakia.

Authors:  M M Wright; A L Grajewski
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

3.  Tono-Pen tonometry in normal and in post-keratoplasty eyes.

Authors:  O Geyer; Y Mayron; A Loewenstein; M Neudorfer; L Rothkoff; M Lazar
Journal:  Br J Ophthalmol       Date:  1992-09       Impact factor: 4.638

4.  Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level.

Authors:  Annette Troost; Kathrin Specht; Frank Krummenauer; Sung Hyun Yun; Oliver Schwenn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-15       Impact factor: 3.117

5.  A comparison of four methods of tonometry: method agreement and interobserver variability.

Authors:  P-A Tonnu; T Ho; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

6.  Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea.

Authors:  A Azuara-Blanco; T K Bhojani; A R Sarhan; C T Pillai; H S Dua
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 4.638

Review 7.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

8.  Tono-Pen, a new tonometer.

Authors:  V Hessemer; R Rössler; K W Jacobi
Journal:  Int Ophthalmol       Date:  1989-01       Impact factor: 2.031

9.  Central corneal thickness in Japanese children.

Authors:  Akiko Hikoya; Miho Sato; Kinnichi Tsuzuki; Yuka Maruyama Koide; Ryo Asaoka; Yoshihiro Hotta
Journal:  Jpn J Ophthalmol       Date:  2009-01-30       Impact factor: 2.447

10.  The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.

Authors:  S Boyraz; I Güngör
Journal:  Ir J Med Sci       Date:  2012-12-04       Impact factor: 1.568