The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then set and measured manometrically while being determined successively with each tonometer over the range of 0-65 mm Hg. Linear regression analysis comparing tonometric and manometric readings showed: (1) minified Goldmann applanation tonometer-slope 0.985 and 0.944, intercept 1.64 and 2.55 mm Hg, correlation coefficient 0.99 and 0.99 in same sized and oversized grafted eyes respectively; (2) pneumatonometer-slope 1.008 and 0.990, intercept 3.37 and 3.69 mm Hg, correlation coefficient 0.99 and 0.98; (3) Tono-Pen-slope 1.061 and 1.002, intercept 5.01 and 4.06 mm Hg, correlation coefficient 0.97 and 0.98. We concluded that the minified Goldmann applanation tonometer is as accurate or more accurate than the pneumatonometer and the Tono-Pen in post-mortem post-keratoplasty human eyes, and may be an economical, convenient alternative to the latter two instruments in clinical practice.

Entities:  

Mesh:

Year:  1994        PMID: 7947545      PMCID: PMC504903          DOI: 10.1136/bjo.78.9.671

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  28 in total

1.  Comparison of the Tono-Pen to the Goldmann applanation tonometer.

Authors:  R E Frenkel; Y J Hong; D H Shin
Journal:  Arch Ophthalmol       Date:  1988-06

2.  Clinical evaluation of the Oculab Tono-Pen.

Authors:  D S Minckler; G Baerveldt; D K Heuer; B Quillen-Thomas; A F Walonker; J Weiner
Journal:  Am J Ophthalmol       Date:  1987-08-15       Impact factor: 5.258

3.  Prognostic factors of intraocular pressure after aphakic keratoplasty.

Authors:  R J Olson; H E Kaufman
Journal:  Am J Ophthalmol       Date:  1978-10       Impact factor: 5.258

4.  The pneumatonograph. A laboratory study.

Authors:  R A Moses; W J Grodzki
Journal:  Arch Ophthalmol       Date:  1979-03

5.  Oversized donor grafts in penetrating keratoplasty. A randomized trial.

Authors:  D G Heidemann; A Sugar; R F Meyer; D C Musch
Journal:  Arch Ophthalmol       Date:  1985-12

6.  Transplant size and elevated intraocular pressure. Postkeratoplasty.

Authors:  T Zimmerman; R Olson; S Waltman; H Kaufman
Journal:  Arch Ophthalmol       Date:  1978-12

7.  The Tono-Pen. A manometric and clinical study.

Authors:  W A Boothe; D A Lee; W C Panek; T H Pettit
Journal:  Arch Ophthalmol       Date:  1988-09

8.  "Minified" Goldmann applanating prism for tonometry in monkeys and humans.

Authors:  P L Kaufman; G E Davis
Journal:  Arch Ophthalmol       Date:  1980-03

9.  Goldmann applanation tonometry in patients with regular corneal astigmatism.

Authors:  J T Holladay; M E Allison; T C Prager
Journal:  Am J Ophthalmol       Date:  1983-07       Impact factor: 5.258

10.  Clinical comparison of the Oculab Tono-Pen to the Goldmann applanation tonometer.

Authors:  S F Kao; P R Lichter; T J Bergstrom; S Rowe; D C Musch
Journal:  Ophthalmology       Date:  1987-12       Impact factor: 12.079

View more
  6 in total

1.  Tono-Pen determination of intraocular pressure in patients with band keratopathy or glued cornea.

Authors:  A Azuara-Blanco; T K Bhojani; A R Sarhan; C T Pillai; H S Dua
Journal:  Br J Ophthalmol       Date:  1998-06       Impact factor: 4.638

2.  The influence of glaucoma history on graft survival after penetrating keratoplasty.

Authors:  T Reinhard; C Kallmann; A Cepin; E Godehardt; R Sundmacher
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1997-09       Impact factor: 3.117

3.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

Review 4.  Graft failure: III. Glaucoma escalation after penetrating keratoplasty.

Authors:  Emily C Greenlee; Young H Kwon
Journal:  Int Ophthalmol       Date:  2008-06       Impact factor: 2.031

5.  Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children.

Authors:  Usha Kaul Raina; Neha Rathie; Anika Gupta; Shantanu Kumar Gupta; Meenakshi Thakar
Journal:  Oman J Ophthalmol       Date:  2016 Jan-Apr

6.  Comparisons of the Tono-Pen® and Goldmann Applanation Tonometer in the Measurement of Intraocular Pressure of Primary Open Angle Glaucoma Patients in a Hospital Population in Southwest Nigeria.

Authors:  Chizoba Onochie; Obiekwe Okoye; Adunola Ogunro; Tade Aribaba; Kunle Hassan; Adeola Onakoya
Journal:  Med Princ Pract       Date:  2016-08-09       Impact factor: 1.927

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.