Using a theory of list-mode maximum-likelihood (ML) source reconstruction presented recently by Barrett et al., this paper formulates a corresponding expectation-maximization (EM) algorithm, as well as a method for estimating noise properties at the ML estimate. List-mode ML is of interest in cases where the dimensionality of the measurement space impedes a binning of the measurement data. It can be advantageous in cases where a better forward model can be obtained by including more measurement coordinates provided by a given detector. Different figures of merit for the detector performance can be computed from the Fisher information matrix (FIM). This paper uses the observed FIM, which requires a single data set, thus, avoiding costly ensemble statistics. The proposed techniques are demonstrated for an idealized two-dimensional (2-D) positron emission tomography (PET) [2-D PET] detector. We compute from simulation data the improved image quality obtained by including the time of flight of the coincident quanta.

Mesh:

Year:  1998        PMID: 9688154      PMCID: PMC2969844          DOI: 10.1109/42.700734

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  7 in total

1.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

2.  An evaluation of maximum likelihood reconstruction for SPECT.

Authors:  E S Chornoboy; C J Chen; M I Miller; T R Miller; D L Snyder
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

3.  A theoretical study of some maximum likelihood algorithms for emission and transmission tomography.

Authors:  K Lange; M Bahn; R Little
Journal:  IEEE Trans Med Imaging       Date:  1987       Impact factor: 10.048

4.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

5.  List-mode likelihood.

Authors:  H H Barrett; T White; L C Parra
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-11       Impact factor: 2.129

6.  Objective assessment of image quality. II. Fisher information, Fourier crosstalk, and figures of merit for task performance.

Authors:  H H Barrett; J L Denny; R F Wagner; K J Myers
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1995-05       Impact factor: 2.129

7.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

  7 in total
  46 in total

1.  Maximum Likelihood Event Estimation and List-mode Image Reconstruction on GPU Hardware.

Authors:  Luca Caucci; Lars R Furenlid; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

2.  FastSPECT II: A Second-Generation High-Resolution Dynamic SPECT Imager.

Authors:  Lars R Furenlid; Donald W Wilson; Yi-Chun Chen; Hyunki Kim; Philip J Pietraski; Michael J Crawford; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-06       Impact factor: 1.679

3.  Image Science with Photon-Processing Detectors.

Authors:  Luca Caucci; Abhinav K Jha; Lars R Furenlid; Eric W Clarkson; Matthew A Kupinski; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2013 Oct-Nov

4.  Maximum-likelihood methods in wavefront sensing: stochastic models and likelihood functions.

Authors:  Harrison H Barrett; Christopher Dainty; David Lara
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-02       Impact factor: 2.129

5.  Benefit of time-of-flight in PET: experimental and clinical results.

Authors:  Joel S Karp; Suleman Surti; Margaret E Daube-Witherspoon; Gerd Muehllehner
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

6.  Analytical properties of time-of-flight PET data.

Authors:  Sanghee Cho; Sangtae Ahn; Quanzheng Li; Richard M Leahy
Journal:  Phys Med Biol       Date:  2008-05-06       Impact factor: 3.609

7.  Optimization of time-of-flight reconstruction on Philips GEMINI TF.

Authors:  Stefaan Vandenberghe; Larry van Elmbt; Michel Guerchaft; Enrico Clementel; Jeroen Verhaeghe; Anne Bol; Ignace Lemahieu; Max Lonneux
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

8.  List-mode MLEM Image Reconstruction from 3D ML Position Estimates.

Authors:  Luca Caucci; William C J Hunter; Lars R Furenlid; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2010-10

9.  List-mode likelihood.

Authors:  H H Barrett; T White; L C Parra
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-11       Impact factor: 2.129

10.  Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

Authors:  Arman Rahmim; Katie Dinelle; Ju-Chieh Cheng; Mikhail A Shilov; William P Segars; Sarah C Lidstone; Stephan Blinder; Olivier G Rousset; Hamid Vajihollahi; Benjamin M W Tsui; Dean F Wong; Vesna Sossi
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.