Literature DB >> 18672420

Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

Arman Rahmim1, Katie Dinelle, Ju-Chieh Cheng, Mikhail A Shilov, William P Segars, Sarah C Lidstone, Stephan Blinder, Olivier G Rousset, Hamid Vajihollahi, Benjamin M W Tsui, Dean F Wong, Vesna Sossi.   

Abstract

With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the same time is very feasible in the context of high-resolution PET. In particular, this paper proposes an effective method to incorporate presence of scattered and random coincidences in the context of motion (which is similarly applicable to various other motion correction schemes). The overall reconstruction framework takes into consideration missing projection data which are not detected due to motion, and additionally, incorporates information from all detected events, including those which fall outside the field-of-view following motion correction. The proposed approach has been extensively validated using phantom experiments as well as realistic simulations of a new mathematical brain phantom developed in this work, and the results for a dynamic patient study are also presented.

Entities:  

Mesh:

Year:  2008        PMID: 18672420      PMCID: PMC2920454          DOI: 10.1109/TMI.2008.917248

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  18 in total

1.  Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling.

Authors:  R Boellaard; A van Lingen; A A Lammertsma
Journal:  J Nucl Med       Date:  2001-05       Impact factor: 10.057

2.  Rapid automated algorithm for aligning and reslicing PET images.

Authors:  R P Woods; S R Cherry; J C Mazziotta
Journal:  J Comput Assist Tomogr       Date:  1992 Jul-Aug       Impact factor: 1.826

3.  Statistical list-mode image reconstruction for the high resolution research tomograph.

Authors:  A Rahmim; M Lenox; A J Reader; C Michel; Z Burbar; T J Ruth; V Sossi
Journal:  Phys Med Biol       Date:  2004-09-21       Impact factor: 3.609

4.  A motion-incorporated reconstruction method for gated PET studies.

Authors:  Feng Qiao; Tinsu Pan; John W Clark; Osama R Mawlawi
Journal:  Phys Med Biol       Date:  2006-07-20       Impact factor: 3.609

5.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Constrained Fourier space method for compensation of missing data in emission computed tomography.

Authors:  J S Karp; G Muehllehner; R M Lewitt
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

7.  Quantitation in positron emission computed tomography: 7. A technique to reduce noise in accidental coincidence measurements and coincidence efficiency calibration.

Authors:  M E Casey; E J Hoffman
Journal:  J Comput Assist Tomogr       Date:  1986 Sep-Oct       Impact factor: 1.826

8.  Imaging human mesolimbic dopamine transmission with positron emission tomography: I. Accuracy and precision of D(2) receptor parameter measurements in ventral striatum.

Authors:  O Mawlawi; D Martinez; M Slifstein; A Broft; R Chatterjee; D R Hwang; Y Huang; N Simpson; K Ngo; R Van Heertum; M Laruelle
Journal:  J Cereb Blood Flow Metab       Date:  2001-09       Impact factor: 6.200

9.  Correction of head movement on PET studies: comparison of methods.

Authors:  Andrew J Montgomery; Kris Thielemans; Mitul A Mehta; Federico Turkheimer; Sanida Mustafovic; Paul M Grasby
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

10.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

Authors:  F Lamare; M J Ledesma Carbayo; T Cresson; G Kontaxakis; A Santos; C Cheze Le Rest; A J Reader; D Visvikis
Journal:  Phys Med Biol       Date:  2007-08-09       Impact factor: 3.609

View more
  22 in total

Review 1.  PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques.

Authors:  Habib Zaidi; Issam El Naqa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-03-25       Impact factor: 9.236

2.  Direct 4D reconstruction of parametric images incorporating anato-functional joint entropy.

Authors:  Jing Tang; Hiroto Kuwabara; Dean F Wong; Arman Rahmim
Journal:  Phys Med Biol       Date:  2010-07-20       Impact factor: 3.609

3.  Feasibility of (18)F-Fluorodeoxyglucose radiotracer dose reduction in simultaneous carotid PET/MR imaging.

Authors:  Mootaz Eldib; Jason Bini; Olivier Lairez; David D Faul; Niels Oesingmann; Zahi A Fayad; Venkatesh Mani
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-06-15

Review 4.  Positron emission tomography molecular imaging in late-life depression.

Authors:  Kentaro Hirao; Gwenn S Smith
Journal:  J Geriatr Psychiatry Neurol       Date:  2014-01-05       Impact factor: 2.680

Review 5.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

6.  Evaluation of motion correction methods in human brain PET imaging--a simulation study based on human motion data.

Authors:  Xiao Jin; Tim Mulnix; Jean-Dominique Gallezot; Richard E Carson
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

7.  System matrix modelling of externally tracked motion.

Authors:  Arman Rahmim; Ju-Chieh Cheng; Katie Dinelle; Mikhail Shilov; W Paul Segars; Olivier G Rousset; Benjamin M W Tsui; Dean F Wong; Vesna Sossi
Journal:  Nucl Med Commun       Date:  2008-06       Impact factor: 1.690

8.  Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

Authors:  Chuan Huang; Yoann Petibon; Jinsong Ouyang; Timothy G Reese; Mark A Ahlman; David A Bluemke; Georges El Fakhri
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

9.  Empirical Bayesian estimation in graphical analysis: a voxel-based approach for the determination of the volume of distribution in PET studies.

Authors:  Francesca Zanderigo; R Todd Ogden; Alessandra Bertoldo; Claudio Cobelli; J John Mann; Ramin V Parsey
Journal:  Nucl Med Biol       Date:  2010-04-07       Impact factor: 2.408

10.  Bayesian PET image reconstruction incorporating anato-functional joint entropy.

Authors:  Jing Tang; Arman Rahmim
Journal:  Phys Med Biol       Date:  2009-11-11       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.