Digital radiology using active matrix readout of amorphous selenium: theoretical analysis of detective quantum efficiency.

W Zhao1, J A Rowlands.   

Abstract

A flat-panel x-ray imaging detector using a layer of amorphous selenium (a-Se) for direct conversion of x rays (to charge) and an active matrix for self-scanned readout is being investigated for digital radiology. A theoretical analysis of the spatial frequency dependent detective quantum efficiency (DQE(f)) of the self-scanned a-Se detector is performed based on a model of signal and noise propagation in a cascaded imaging system. Because of the high intrinsic resolution of a-Se and the pixelated active matrix readout method, such detectors are inherently undersampled and aliasing is present. The presampling modulation transfer function (MTF) and aliased noise power spectrum (NPS) of the detector were used in the analysis of DQE(f). It is proven that the aliased NPS for the self-scanned a-Se detectors is white. Since the shape of DQE(f) is determined by the ratio of MTF squared and the NPS, the shape of DQE(f) follows the square of the presampling MTF of the detector as a result of the white NPS. The analysis also shows that DQE(0) is proportional to the pixel fill factor, i.e., the fraction of each pixel area used for image charge collection. The DQE analysis is applied to detector parameters for three x-ray imaging applications: mammography, chest radiography, and fluoroscopy. The effects of pixel fill factor, imaging geometry (i.e., incident angle of x rays), and various sources of electronic noise on the detector DQE(f) are discussed. Strategies for maximizing detector DQE for each x-ray imaging application are proposed.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9434965     DOI: 10.1118/1.598097

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; D Albagli; S Han; E J Tkaczyk; C E Landberg; B Opsahl-Ong; P R Granfors; I Levis; C J D'Orsi; R E Hendrick
Journal:  Med Phys       Date:  2000-03       Impact factor: 4.071

2.  Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

Authors:  S Vedantham; A Karellas; S Suryanarayanan; C J D'Orsi; R E Hendrick
Journal:  J Digit Imaging       Date:  2000-11       Impact factor: 4.056

3.  Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

4.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Effect of repeated x-ray exposure on the resolution of amorphous selenium based x-ray imagers.

Authors:  M Z Kabir; L Chowdhury; G DeCrescenzo; O Tousignant; S O Kasap; J A Rowlands
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

6.  Comparison of model and human observer performance for detection and discrimination tasks using dual-energy x-ray images.

Authors:  Samuel Richard; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

7.  Experimental validation of a three-dimensional linear system model for breast tomosynthesis.

Authors:  Bo Zhao; Jun Zhou; Yue-Houng Hu; Thomas Mertelmeier; Jasmina Ludwig; Wei Zhao
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

8.  Image artifacts in digital breast tomosynthesis: investigation of the effects of system geometry and reconstruction parameters using a linear system approach.

Authors:  Yue-Houng Hu; Bo Zhao; Wei Zhao
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

9.  Quantification of breast density with dual energy mammography: a simulation study.

Authors:  Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

10.  Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.

Authors:  Daniel J Tward; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.