Literature DB >> 9358462

Signal-to-noise measurements in magnitude images from NMR phased arrays.

C D Constantinides1, E Atalar, E R McVeigh.   

Abstract

A method is proposed to estimate signal-to-noise ratio (SNR) values in phased array magnitude images, based on a region-of-interest (ROI) analysis. It is shown that the SNR can be found by correcting the measured signal intensity for the noise bias effects and by evaluating the noise variance as the mean square value of all the pixel intensities in a chosen background ROI, divided by twice the number of receivers used. Estimated SNR values are shown to vary spatially within a bound of 20% with respect to the true SNR values as a result of noise correlations between receivers.

Mesh:

Year:  1997        PMID: 9358462      PMCID: PMC2570034          DOI: 10.1002/mrm.1910380524

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Noise correlations exist for independent RF coils.

Authors:  M D Harpen
Journal:  Magn Reson Med       Date:  1992-02       Impact factor: 4.668

2.  Noise correlations in data simultaneously acquired from multiple surface coil arrays.

Authors:  C E Hayes; P B Roemer
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

3.  Noise correlation in multicoil receiver systems.

Authors:  T W Redpath
Journal:  Magn Reson Med       Date:  1992-03       Impact factor: 4.668

4.  Noise correlation.

Authors:  A Jesmanowicz; J S Hyde; W Froncisz; J B Kneeland
Journal:  Magn Reson Med       Date:  1991-07       Impact factor: 4.668

5.  A phased array coil for human cardiac imaging.

Authors:  C D Constantinides; C R Westgate; W G O'Dell; E A Zerhouni; E R McVeigh
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

6.  Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils.

Authors:  J Wang; A Reykowski; J Dickas
Journal:  IEEE Trans Biomed Eng       Date:  1995-09       Impact factor: 4.538

7.  An unbiased signal-to-noise ratio measure for magnetic resonance images.

Authors:  G McGibney; M R Smith
Journal:  Med Phys       Date:  1993 Jul-Aug       Impact factor: 4.071

8.  The Rician distribution of noisy MRI data.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

9.  The use of power images to perform quantitative analysis on low SNR MR images.

Authors:  A J Miller; P M Joseph
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

10.  An NMR phased array for human cardiac 31P spectroscopy.

Authors:  C J Hardy; P A Bottomley; K W Rohling; P B Roemer
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

View more
  163 in total

1.  Investigation of complex phased array coil designs for cardiac imaging.

Authors:  M Nittka; A Haase
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Multishot EPI-SSFP in the heart.

Authors:  Daniel A Herzka; Peter Kellman; Anthony H Aletras; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2002-04       Impact factor: 4.668

3.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

4.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

5.  Coil compression for accelerated imaging with Cartesian sampling.

Authors:  Tao Zhang; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-04-09       Impact factor: 4.668

6.  Measuring signal-to-noise ratio in partially parallel imaging MRI.

Authors:  Frank L Goerner; Geoffrey D Clarke
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

7.  Optimal real-time estimation in diffusion tensor imaging.

Authors:  Pablo Casaseca-de-la-Higuera; Antonio Tristán-Vega; Santiago Aja-Fernández; Carlos Alberola-López; Carl-Fredrik Westin; Raúl San José Estépar
Journal:  Magn Reson Imaging       Date:  2012-02-02       Impact factor: 2.546

8.  Feasibility of 7T MRI for imaging fascicular structures of peripheral nerves.

Authors:  Daehyun Yoon; Sandip Biswal; Brian Rutt; Amelie Lutz; Brian Hargreaves
Journal:  Muscle Nerve       Date:  2017-12-22       Impact factor: 3.217

9.  Feasibility of in vivo diffusion tensor imaging of articular cartilage with coverage of all cartilage regions.

Authors:  José G Raya; Eike Dettmann; Mike Notohamiprodjo; Svetlana Krasnokutsky; Steven Abramson; Christian Glaser
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

10.  The impact of gradient strength on in vivo diffusion MRI estimates of axon diameter.

Authors:  Susie Y Huang; Aapo Nummenmaa; Thomas Witzel; Tanguy Duval; Julien Cohen-Adad; Lawrence L Wald; Jennifer A McNab
Journal:  Neuroimage       Date:  2014-12-09       Impact factor: 6.556

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.