This paper describes a new method to calculate the signal-to-noise ratio (SNR) of MR signals obtained from single receiver coils and arrays of receiver coils. The coils are assumed to be place on the surface of a conducting half-space and the SNR is sample-noise dominated. While in conventional methods line integrals over the electric currents in the coils are chosen to calculate the electric and magnetic fields, this new method uses surface integrals over magnetic dipoles covering the area enclosed by the antenna to derive these fields. Using this method, the SNR for simple circular and square coils was analytically calculated. The calculations show that the theoretical difference in SNR between circular and square antennas is very low. Furthermore, based on the new method, a derivation of the ultimate gain in SNR for arrays of surface coils is presented. The SNR of such an array approaches a limit even if the total number of coils is increased to infinity. This ultimate SNR of a coil array is 35.8% above that of a single circular-shaped, size-optimized and linear polarized coil.

Mesh:

Year:  1995        PMID: 7558065     DOI: 10.1109/10.412657

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  18 in total

1.  An analytical SMASH procedure (ASP) for sensitivity-encoded MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; P A Bottomley
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Cardiovascular MRI probes for the outside in and for the inside out.

Authors:  P A Bottomley; E Atalar; R F Lee; K A Shunk; A Lardo
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

3.  Lumped-element planar strip array (LPSA) for parallel MRI.

Authors:  Ray F Lee; Christopher J Hardy; Daniel K Sodickson; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

Authors:  Daniel K Sodickson; Christopher J Hardy; Yudong Zhu; Randy O Giaquinto; Patrick Gross; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Aaron K Grant; Neil M Rofsky
Journal:  Acad Radiol       Date:  2005-05       Impact factor: 3.173

5.  Absolute Temperature Monitoring Using RF Radiometry in the MRI Scanner.

Authors:  Abdel-Monem M El-Sharkawy; Paul P Sotiriadis; Paul A Bottomley; Ergin Atalar
Journal:  IEEE Trans Circuits Syst I Regul Pap       Date:  2006-11       Impact factor: 3.605

Review 6.  Human cardiac spectroscopy.

Authors:  P A Bottomley; R G Weiss
Journal:  MAGMA       Date:  1998-09       Impact factor: 2.310

7.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

8.  Radiofrequency artefacts in echoplanar imaging induced by two 1.5 T MR scanners in close proximity.

Authors:  X Li; J Cui; S P Christopasak; A Kumar; Z-G Peng
Journal:  Br J Radiol       Date:  2014-04-09       Impact factor: 3.039

9.  An 11-channel radio frequency phased array coil for magnetic resonance guided high-intensity focused ultrasound of the breast.

Authors:  E Minalga; A Payne; R Merrill; N Todd; S Vijayakumar; E Kholmovski; D L Parker; J R Hadley
Journal:  Magn Reson Med       Date:  2012-03-16       Impact factor: 4.668

10.  A 20-channel coil for improved magnetic resonance imaging of the optic nerve.

Authors:  Emilee Minalga; John Rose; Seong-Eun Choi; Eun-Kee Jeong; Eugene Kholmovski; Sathya Vijayakumar; Dennis Parker; Rock Hadley
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-02-25       Impact factor: 1.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.