Literature DB >> 7674903

A phased array coil for human cardiac imaging.

C D Constantinides1, C R Westgate, W G O'Dell, E A Zerhouni, E R McVeigh.   

Abstract

A prototype cardiac phased array receiver coil was constructed that comprised a cylindrical array and a separate planar array. Both arrays had two coil loops with the same coil dimensions. Data acquisition with the cylindrical array placed on the human chest, and the planar array placed under the back, yielded an overall enhancement of the signal-to-noise ratio (SNR) over the entire heart by a factor of 1.1-2.85 over a commercially available flexible coil and a commercially available four-loop planar phased array coil. This improvement in SNR can be exploited in cardiac imaging to increase the spatial resolution and reduce the image acquisition time.

Entities:  

Mesh:

Year:  1995        PMID: 7674903      PMCID: PMC2396277          DOI: 10.1002/mrm.1910340114

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Cardiac tagging with breath-hold cine MRI.

Authors:  E R McVeigh; E Atalar
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

2.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

3.  Volume imaging with MR phased arrays.

Authors:  C E Hayes; N Hattes; P B Roemer
Journal:  Magn Reson Med       Date:  1991-04       Impact factor: 4.668

4.  Switched surface coil system for bilateral MR imaging.

Authors:  C J Hardy; R W Katzberg; R L Frey; J Szumowski; S Totterman; O M Mueller
Journal:  Radiology       Date:  1988-06       Impact factor: 11.105

5.  Phase and sensitivity of receiver coils in magnetic resonance imaging.

Authors:  E R McVeigh; M J Bronskill; R M Henkelman
Journal:  Med Phys       Date:  1986 Nov-Dec       Impact factor: 4.071

6.  Measurement of signal intensities in the presence of noise in MR images.

Authors:  R M Henkelman
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

7.  Phosphate metabolite imaging and concentration measurements in human heart by nuclear magnetic resonance.

Authors:  P A Bottomley; C J Hardy; P B Roemer
Journal:  Magn Reson Med       Date:  1990-06       Impact factor: 4.668

8.  A signal-to-noise calibration procedure for NMR imaging systems.

Authors:  W A Edelstein; P A Bottomley; L M Pfeifer
Journal:  Med Phys       Date:  1984 Mar-Apr       Impact factor: 4.071

9.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.

Authors:  E A Zerhouni; D M Parish; W J Rogers; A Yang; E P Shapiro
Journal:  Radiology       Date:  1988-10       Impact factor: 11.105

10.  An NMR phased array for human cardiac 31P spectroscopy.

Authors:  C J Hardy; P A Bottomley; K W Rohling; P B Roemer
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

View more
  6 in total

1.  Investigation of complex phased array coil designs for cardiac imaging.

Authors:  M Nittka; A Haase
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

2.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

3.  A 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments.

Authors:  Mark Haig Khachaturian
Journal:  J Biomed Sci Eng       Date:  2010-01-01

Review 4.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

5.  INTERCOMPARISON OF PERFORMANCE OF RF COIL GEOMETRIES FOR HIGH FIELD MOUSE CARDIAC MRI.

Authors:  Christakis Constantinides; S Angeli; S Gkagkarellis; G Cofer
Journal:  Concepts Magn Reson Part A Bridg Educ Res       Date:  2011-09       Impact factor: 0.481

6.  Three-dimensional balanced steady state free precession myocardial perfusion cardiovascular magnetic resonance at 3T using dual-source parallel RF transmission: initial experience.

Authors:  Roy Jogiya; Andreas Schuster; Arshad Zaman; Manish Motwani; Marc Kouwenhoven; Eike Nagel; Sebastian Kozerke; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2014-11-28       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.