Literature DB >> 9268076

Non-breath-hold lung magnetic resonance imaging with real-time navigation.

M A Schmidt1, G Z Yang, J Keegan, P Jhooti, P D Gatehouse, D H Carr, D M Hansell, D N Firmin.   

Abstract

Magnetic resonance imaging (MRI) with navigating techniques based on consecutive breath-holds demand a level of respiratory control that is often beyond the capability of patients with lung disease. The objectives of this investigation were to develop and evaluate a navigating technique for lung MRI that does not rely on patient cooperation. Navigating techniques were implemented at 0.5 T using conventional imaging techniques of short echo-time and imaging during normal breathing in the diastolic phase of the cardiac cycle. A column of spins, orthogonal to the diaphragm, was excited both immediately before and after the imaging segment. These signals were processed in real time to provide the position of the lung-diaphragm interface. An imaging segment was considered correctly acquired only when the interface position was within the acceptance window both before and after the acquisition of the segment. A distribution of lung-diaphragm interface positions obtained during normal respiration was employed to define the acceptance window. In the case of multislice techniques, the position of the lung-diaphragm interface immediately before the imaging segment was also employed to decide which phase-encoding step to acquire next, therefore reducing the apparent frequency of the respiratory motion. A distribution of interface positions, updated in real time, served as a reference for the allocation of phase-encoding steps according to diaphragm position. The lung images obtained represent a significant advance in image quality, improving further the ability of MR to detect and monitor pulmonary disease. Motion artifacts were reduced, and images reliably demonstrated smaller vessels, which are not normally visible without navigation.

Entities:  

Mesh:

Year:  1997        PMID: 9268076     DOI: 10.1007/bf02592243

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  8 in total

1.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

2.  Lung parenchyma: magnetic susceptibility in MR imaging.

Authors:  C J Bergin; G H Glover; J M Pauly
Journal:  Radiology       Date:  1991-09       Impact factor: 11.105

3.  Multi-slice, breathhold imaging of the lung with submillisecond echo times.

Authors:  D C Alsop; H Hatabu; M Bonnet; J Listerud; W Gefter
Journal:  Magn Reson Med       Date:  1995-05       Impact factor: 4.668

4.  3D MR angiography of pulmonary arteries using real-time navigator gating and magnetization preparation.

Authors:  Y Wang; P J Rossman; R C Grimm; A H Wilman; S J Riederer; R L Ehman
Journal:  Magn Reson Med       Date:  1996-10       Impact factor: 4.668

5.  A monitoring, feedback, and triggering system for reproducible breath-hold MR imaging.

Authors:  Y L Liu; S J Riederer; P J Rossman; R C Grimm; J P Debbins; R L Ehman
Journal:  Magn Reson Med       Date:  1993-10       Impact factor: 4.668

6.  Real-time motion detection in spiral MRI using navigators.

Authors:  T S Sachs; C H Meyer; B S Hu; J Kohli; D G Nishimura; A Macovski
Journal:  Magn Reson Med       Date:  1994-11       Impact factor: 4.668

7.  Measurement of lung water content and pleural pressure gradient with magnetic resonance imaging.

Authors:  J R Mayo; A L MacKay; K P Whittall; E M Baile; P D Paré
Journal:  J Thorac Imaging       Date:  1995       Impact factor: 3.000

8.  MR imaging of the lungs: value of short TE spin-echo pulse sequences.

Authors:  J R Mayo; A MacKay; N L Müller
Journal:  AJR Am J Roentgenol       Date:  1992-11       Impact factor: 3.959

  8 in total
  5 in total

Review 1.  [Magnetic resonance imaging in the evaluation of pneumonia].

Authors:  R Eibel; P Herzog; O Dietrich; C Rieger; H Ostermann; M Reiser; S Schoenberg
Journal:  Radiologe       Date:  2006-04       Impact factor: 0.635

Review 2.  Advances in functional and structural imaging of the human lung using proton MRI.

Authors:  G Wilson Miller; John P Mugler; Rui C Sá; Talissa A Altes; G Kim Prisk; Susan R Hopkins
Journal:  NMR Biomed       Date:  2014-07-02       Impact factor: 4.044

3.  Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines.

Authors:  Peter Bannas; Laura C Bell; Kevin M Johnson; Mark L Schiebler; Christopher J François; Utaroh Motosugi; Daniel Consigny; Scott B Reeder; Scott K Nagle
Journal:  Radiology       Date:  2015-09-30       Impact factor: 11.105

4.  Functional MRI of the Lungs Using Single Breath-Hold and Self-Navigated Ultrashort Echo Time Sequences.

Authors:  Julius F Heidenreich; Simon Veldhoen; Corona Metz; Lenon Mendes Pereira; Thomas Benkert; Josef Pfeuffer; Thorsten A Bley; Herbert Köstler; Andreas M Weng
Journal:  Radiol Cardiothorac Imaging       Date:  2020-06-25

5.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.