Literature DB >> 7596272

Multi-slice, breathhold imaging of the lung with submillisecond echo times.

D C Alsop1, H Hatabu, M Bonnet, J Listerud, W Gefter.   

Abstract

The signal from the lungs is heavily attenuated by T2 and T2 decay in standard MR images of the thorax. The authors utilized the capabilities of a prototype fast gradient system to develop a multi-slice gradient echo sequence that can obtain images with an echo time of 0.7 ms. Images acquired in a single breath-hold are free from respiratory motion artifacts and clearly display signal from lung parenchyma. The use of fast gradients makes short echo times possible without the use of nonstandard RF pulses and spatial encoding techniques and their associated limitations.

Entities:  

Mesh:

Year:  1995        PMID: 7596272     DOI: 10.1002/mrm.1910330513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

Review 1.  Contrast-enhanced pulmonary MR imaging.

Authors:  O Haraldseth; T Amundsen; P A Rinck
Journal:  MAGMA       Date:  1999-08       Impact factor: 2.310

Review 2.  MR imaging of the pulmonary vasculature--an update.

Authors:  Mark R Pedersen; Mark T Fisher; Edwin J R van Beek
Journal:  Eur Radiol       Date:  2006-01-04       Impact factor: 5.315

3.  Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.

Authors:  Cheng Hong; Jason C Leawoods; Dmitriy A Yablonskiy; John R Leyendecker; Kyongtae T Bae; Thomas K Pilgram; Pamela K Woodard; Mark S Conradi; Jie Zheng
Journal:  Acad Radiol       Date:  2005-02       Impact factor: 3.173

4.  Medial temporal lobe involvement in an implicit memory task: evidence of collaborating implicit and explicit memory systems from FMRI and Alzheimer's disease.

Authors:  Phyllis Koenig; Edward E Smith; Vanessa Troiani; Chivon Anderson; Peachie Moore; Murray Grossman
Journal:  Cereb Cortex       Date:  2008-04-09       Impact factor: 5.357

5.  Young Investigator Award presentation at the 13th annual meeting of the ESMRMB, September 1996, Prague. Quantification of pulmonary water compartments by magnetic resonance.

Authors:  J Lehmann; J C Böck; P Podrabsky; W Wlodarczyk; R Felix
Journal:  MAGMA       Date:  1997-03       Impact factor: 2.310

6.  Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study.

Authors:  Kyungsoo Bae; Kyung Nyeo Jeon; Moon Jung Hwang; Joon Sung Lee; Ji Young Ha; Kyeong Hwa Ryu; Ho Cheol Kim
Journal:  Eur Radiol       Date:  2018-12-13       Impact factor: 5.315

7.  Ultra-short echo time (UTE) MR imaging of the lung: comparison between normal and emphysematous lungs in mutant mice.

Authors:  Masaya Takahashi; Osamu Togao; Makoto Obara; Marc van Cauteren; Yoshiharu Ohno; Shigehiro Doi; Makoto Kuro-o; Craig Malloy; Connie C Hsia; Ivan Dimitrov
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

8.  Longitudinal free-breathing MRI measurement of murine lung physiology in a progressive model of lung fibrosis.

Authors:  Jinbang Guo; William D Hardie; Zackary I Cleveland; Cynthia Davidson; Xuefeng Xu; Satish K Madala; Jason C Woods
Journal:  J Appl Physiol (1985)       Date:  2019-02-07

9.  Monitoring infection and inflammation in murine models of cystic fibrosis with magnetic resonance imaging.

Authors:  Vipul R Sheth; R Christiaan van Heeckeren; Alma G Wilson; Anna M van Heeckeren; Mark D Pagel
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

10.  Functional neuroimaging of dressing-related skills.

Authors:  George F Wittenberg; Christopher T Lovelace; Donald J Foster; Joseph A Maldjian
Journal:  Brain Imaging Behav       Date:  2014-09       Impact factor: 3.978

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.