Literature DB >> 1414805

MR imaging of the lungs: value of short TE spin-echo pulse sequences.

J R Mayo1, A MacKay, N L Müller.   

Abstract

OBJECTIVE: An experimental short echo delay (TE = 7 msec) T1-weighted spin-echo sequence was compared with a conventional (TE = 20 msec) T1-weighted spin-echo sequence in the assessment of normal and abnormal lung parenchyma. Comparison was also made with high-resolution CT of abnormal lung parenchyma. SUBJECTS AND
METHOD: At 1.5 T, an experimental short echo delay T1-weighted multislice spin-echo sequence (TR = RR interval, TE = 7 msec) was compared with an optimal conventional T1-weighted spin-echo sequence (TR = RR interval, TE = 20 msec, spatial presaturation). Ten healthy volunteers were examined with both sequences. The mean signal intensity and signal-to-noise ratios were calculated in lung parenchyma for both sequences. Two radiologists compared the visualization of normal lung parenchymal structures with the two techniques. In 24 patients with diffuse lung disease, results with both MR sequences and with high-resolution CT were compared.
RESULTS: The signal intensity was significantly greater (p < .001) with the TE of 7 msec than with the TE of 20 msec, resulting in a 3.5-fold improvement in the signal-to-noise ratio. The 7-msec TE improved visualization of lung parenchymal structures, including peripheral vessels, interlobular septa or veins, and centrilobular arteries. In the patients with diffuse lung disease, pulmonary parenchymal abnormalities were better visualized on the images with TEs of 7 msec than on images with TEs of 20 msec. When compared with high-resolution CT, the sequence with a TE of 7 msec provided comparable assessment of air-space opacification and dense consolidation, but it was inferior to high-resolution CT in the anatomic assessment of lung parenchyma.
CONCLUSION: This experimental spin-echo sequence with a TE of 7 msec significantly improves the signal-to-noise ratio, allowing improved visualization of normal and abnormal pulmonary parenchyma when compared with conventional spin-echo images with a TE of 20 msec. Although anatomic detail remains inferior to that seen with high-resolution CT, the improved image quality with a TE of 7 msec suggests that assessment and follow-up of parenchymal lung disease might be possible with MR, thereby avoiding ionizing radiation.

Entities:  

Mesh:

Year:  1992        PMID: 1414805     DOI: 10.2214/ajr.159.5.1414805

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  19 in total

Review 1.  Quantitative pulmonary imaging using computed tomography and magnetic resonance imaging.

Authors:  George R Washko; Grace Parraga; Harvey O Coxson
Journal:  Respirology       Date:  2012-04       Impact factor: 6.424

Review 2.  Assessment of pulmonary hypertension by CT and MR imaging.

Authors:  Sebastian Ley; Karl-Friedrich Kreitner; Christian Fink; Claus P Heussel; Mathias M Borst; Hans-Ulrich Kauczor
Journal:  Eur Radiol       Date:  2004-01-23       Impact factor: 5.315

3.  Detection of Small Pulmonary Nodules with Ultrashort Echo Time Sequences in Oncology Patients by Using a PET/MR System.

Authors:  Nicholas S Burris; Kevin M Johnson; Peder E Z Larson; Michael D Hope; Scott K Nagle; Spencer C Behr; Thomas A Hope
Journal:  Radiology       Date:  2015-07-02       Impact factor: 11.105

4.  Free breathing 1H MRI of the human lung with an improved radial turbo spin-echo.

Authors:  Michael Völker; Philipp Ehses; Stefan Weick; Felix Arno Breuer; Martin Blaimer; Christian Hintze; Jürgen Biederer; Peter Michael Jakob
Journal:  MAGMA       Date:  2014-11-08       Impact factor: 2.310

5.  A radial sampling strategy for uniform k-space coverage with retrospective respiratory gating in 3D ultrashort-echo-time lung imaging.

Authors:  Jinil Park; Taehoon Shin; Soon Ho Yoon; Jin Mo Goo; Jang-Yeon Park
Journal:  NMR Biomed       Date:  2016-02-18       Impact factor: 4.044

6.  Ultrashort Echo-Time Magnetic Resonance Imaging Is a Sensitive Method for the Evaluation of Early Cystic Fibrosis Lung Disease.

Authors:  David J Roach; Yannick Crémillieux; Robert J Fleck; Alan S Brody; Suraj D Serai; Rhonda D Szczesniak; Stephanie Kerlakian; John P Clancy; Jason C Woods
Journal:  Ann Am Thorac Soc       Date:  2016-11

7.  Comparative evaluation of chest radiography, low-field MRI, the Shwachman-Kulczycki score and pulmonary function tests in patients with cystic fibrosis.

Authors:  Angela Anjorin; Helga Schmidt; Hans-Georg Posselt; Christina Smaczny; Hanns Ackermann; Michael Deimling; Thomas J Vogl; Nasreddin Abolmaali
Journal:  Eur Radiol       Date:  2008-02-15       Impact factor: 5.315

8.  Diffusion Weighted Magnetic Resonance Imaging for the Characterization of Solitary Pulmonary Lesions.

Authors:  Çağlayan Çakır; Hakan Gençhellaç; Osman Temizöz; Ahmet Polat; Ersin Şengül; Gökhan Duygulu
Journal:  Balkan Med J       Date:  2015-10-01       Impact factor: 2.021

9.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

10.  Motion robust high resolution 3D free-breathing pulmonary MRI using dynamic 3D image self-navigator.

Authors:  Wenwen Jiang; Frank Ong; Kevin M Johnson; Scott K Nagle; Thomas A Hope; Michael Lustig; Peder E Z Larson
Journal:  Magn Reson Med       Date:  2017-10-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.