Literature DB >> 7808265

Real-time motion detection in spiral MRI using navigators.

T S Sachs1, C H Meyer, B S Hu, J Kohli, D G Nishimura, A Macovski.   

Abstract

A technique has been developed whereby motion can be detected in real time during the acquisition of data. This enables the implementation of an algorithm to accept or reject and reacquire data during a scan. Frames of data with motion are rejected and reacquired on the fly so that by the end of the scan, a complete motion-free data set has been acquired. The algorithm has been implemented on several different types of sequences. Preliminary in vivo studies indicate that motion artifacts are dramatically reduced.

Mesh:

Year:  1994        PMID: 7808265     DOI: 10.1002/mrm.1910320513

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  A comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiography.

Authors:  Y P Du; E R McVeigh; D A Bluemke; H A Silber; T K Foo
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

Review 2.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

3.  Basic considerations on the impact of the coil array on the performance of Transmit SENSE.

Authors:  U Katscher; J Röhrs; P Börnert
Journal:  MAGMA       Date:  2005-02-11       Impact factor: 2.310

4.  Dual-contrast single breath-hold 3D abdominal MR imaging.

Authors:  Richard Winkelmann; Peter Börnert; Jan De Becker; Romhild Hoogeveen; Peter Mazurkewitz; Olaf Dössel
Journal:  MAGMA       Date:  2006-11-24       Impact factor: 2.310

Review 5.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

6.  Free-breathing cardiac MR stress perfusion with real-time slice tracking.

Authors:  Tamer A Basha; Sébastien Roujol; Kraig V Kissinger; Beth Goddu; Sophie Berg; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-10-07       Impact factor: 4.668

7.  Two-dimensional coronary MRA: limitations and artifacts.

Authors:  A J Duerinckx; D P Atkinson; J Mintorovitch; O P Simonetti; M K Vrman
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

8.  Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

Authors:  Ralf B Loeffler; M Beth McCarville; Anne W Wagstaff; Matthew P Smeltzer; Axel J Krafft; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand
Journal:  Pediatr Radiol       Date:  2016-10-17

9.  Free-breathing 3D steady-state free precession coronary magnetic resonance angiography: comparison of diaphragm and cardiac fat navigators.

Authors:  Thanh D Nguyen; Pascal Spincemaille; Matthew D Cham; Jonathan W Weinsaft; Martin R Prince; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

10.  Rapid-motion-perception based cardiac navigators: using the high flow blood volume as a marker for the position of the heart.

Authors:  Vinay M Pai; Han Wen
Journal:  J Cardiovasc Magn Reson       Date:  2003       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.