Literature DB >> 23213020

Optimized 3D ultrashort echo time pulmonary MRI.

Kevin M Johnson1, Sean B Fain, Mark L Schiebler, Scott Nagle.   

Abstract

PURPOSE: To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging.
METHODS: 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phantom studies. Their effects on lung and airway visualization in five healthy male human subjects (mean age 32 years) were compared qualitatively through blinded ordinal scoring by two cardiothoracic radiologists using a nonparametric Friedman test (P < 0.05). Relative signal difference between endobronchial air and adjacent lung tissue, normalized to nearby vessel, was used as a surrogate for lung tissue signal. Quantitative measures were compared using the paired Student's t-test (P < 0.05). Finally, clinical feasibility was investigated in a patient with interstitial fibrosis.
RESULTS: Simulation and phantom studies showed up to 67% improvement in SNR and reduced blurring for short T2* species using all three optimizations. In vivo images showed decreased artifacts and improved lung tissue and airway visualization both qualitatively and quantitatively.
CONCLUSION: The use of limited field-of-view excitation, variable readout gradients, and radial oversampling significantly improve the technical quality of 3D radial ultrashort echo time lung images.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  MRI; lung; radial imaging; ultrashort echo time

Mesh:

Year:  2012        PMID: 23213020      PMCID: PMC4199575          DOI: 10.1002/mrm.24570

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  58 in total

1.  T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging.

Authors:  H Hatabu; D C Alsop; J Listerud; M Bonnet; W B Gefter
Journal:  Eur J Radiol       Date:  1999-03       Impact factor: 3.528

2.  Self-calibrating parallel imaging with automatic coil sensitivity extraction.

Authors:  Charles A McKenzie; Ernest N Yeh; Michael A Ohliger; Mark D Price; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2002-03       Impact factor: 4.668

3.  Consequences of T2 relaxation during half-pulse slice selection for ultrashort TE imaging.

Authors:  Matthew D Robson; Peter D Gatehouse
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

4.  Lung parenchyma: projection reconstruction MR imaging.

Authors:  C J Bergin; J M Pauly; A Macovski
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

5.  Designing long-T2 suppression pulses for ultrashort echo time imaging.

Authors:  Peder E Z Larson; Paul T Gurney; Krishna Nayak; Garry E Gold; John M Pauly; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  Sodium MRI using a density-adapted 3D radial acquisition technique.

Authors:  Armin M Nagel; Frederik B Laun; Marc-André Weber; Christian Matthies; Wolfhard Semmler; Lothar R Schad
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

7.  Early detection of lung inflammation: exploiting T1-effects of iron oxide particles using UTE MRI.

Authors:  Klaus Strobel; Verena Hoerr; Florian Schmid; Lydia Wachsmuth; Bettina Löffler; Cornelius Faber
Journal:  Magn Reson Med       Date:  2012-02-24       Impact factor: 4.668

Review 8.  MRI using hyperpolarized noble gases.

Authors:  H Kauczor; R Surkau; T Roberts
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

9.  Lung MRI at 3.0 T: a comparison of helical CT and high-field MRI in the detection of diffuse lung disease.

Authors:  G Lutterbey; J Gieseke; M von Falkenhausen; N Morakkabati; H Schild
Journal:  Eur Radiol       Date:  2004-11-23       Impact factor: 5.315

10.  Water- and fat-suppressed proton projection MRI (WASPI) of rat femur bone.

Authors:  Yaotang Wu; Guangping Dai; Jerome L Ackerman; Mirko I Hrovat; Melvin J Glimcher; Brian D Snyder; Ara Nazarian; David A Chesler
Journal:  Magn Reson Med       Date:  2007-03       Impact factor: 4.668

View more
  114 in total

1.  Assessment of Silent T1-weighted head imaging at 7 T.

Authors:  Mauro Costagli; Mark R Symms; Lorenzo Angeli; Douglas A C Kelley; Laura Biagi; Andrea Farnetani; Catarina Rua; Graziella Donatelli; Gianluigi Tiberi; Michela Tosetti; Mirco Cosottini
Journal:  Eur Radiol       Date:  2015-08-29       Impact factor: 5.315

2.  Dose and pulse sequence considerations for hyperpolarized (129)Xe ventilation MRI.

Authors:  Mu He; Scott H Robertson; S Sivaram Kaushik; Matthew S Freeman; Rohan S Virgincar; John Davies; Jane Stiles; William M Foster; H Page McAdams; Bastiaan Driehuys
Journal:  Magn Reson Imaging       Date:  2015-04-30       Impact factor: 2.546

3.  Imaging mouse lung allograft rejection with (1)H MRI.

Authors:  Jinbang Guo; Howard J Huang; Xingan Wang; Wei Wang; Henry Ellison; Robert P Thomen; Andrew E Gelman; Jason C Woods
Journal:  Magn Reson Med       Date:  2014-06-20       Impact factor: 4.668

4.  Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study.

Authors:  Kyungsoo Bae; Kyung Nyeo Jeon; Moon Jung Hwang; Joon Sung Lee; Ji Young Ha; Kyeong Hwa Ryu; Ho Cheol Kim
Journal:  Eur Radiol       Date:  2018-12-13       Impact factor: 5.315

5.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

6.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

7.  Perfusion of the placenta assessed using arterial spin labeling and ferumoxytol dynamic contrast enhanced magnetic resonance imaging in the rhesus macaque.

Authors:  Kai D Ludwig; Sean B Fain; Sydney M Nguyen; Thaddeus G Golos; Scott B Reeder; Ian M Bird; Dinesh M Shah; Oliver E Wieben; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2018-10-25       Impact factor: 4.668

8.  Assessment of regional lung function with multivolume (1)H MR imaging in health and obstructive lung disease: comparison with (3)He MR imaging.

Authors:  Francesca Pennati; James D Quirk; Dmitriy A Yablonskiy; Mario Castro; Andrea Aliverti; Jason C Woods
Journal:  Radiology       Date:  2014-06-15       Impact factor: 11.105

9.  Three-dimensional Isotropic Functional Imaging of Cystic Fibrosis Using Oxygen-enhanced MRI: Comparison with Hyperpolarized 3He MRI.

Authors:  Wei Zha; Scott K Nagle; Robert V Cadman; Mark L Schiebler; Sean B Fain
Journal:  Radiology       Date:  2018-10-23       Impact factor: 11.105

Review 10.  Magnetic resonance and computed tomography imaging of the structural and functional changes of pulmonary arterial hypertension.

Authors:  Mark L Schiebler; Sanjeev Bhalla; James Runo; Nizar Jarjour; Alejandro Roldan; Naomi Chesler; Christopher J François
Journal:  J Thorac Imaging       Date:  2013-05       Impact factor: 3.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.