Literature DB >> 9160941

Digital edge-detection measurement of polyethylene wear after total hip arthroplasty.

S M Shaver1, T D Brown, S L Hillis, J J Callaghan.   

Abstract

A novel digital edge-detection computer technique was developed to measure polyethylene wear after total hip arthroplasty. The new method objectively infers the margins of the component by evaluating gradients of gray-scale intensity on digitized images of the radiographs. Compared with previous methods for measurement of wear, digital edge detection substantially reduces observer subjectivity. The technique was validated directly by measuring wear artificially produced by spherical-front milling of polyethylene liners in a benchtop series. Under such conditions, digital edge detection proved 6.4 times more accurate and 7.1 times more reproducible than manual measurement with conventional circular templates. In addition, clinical application of the new digital imaging technique was illustrated in a series of forty-three patients in whom a metal-backed acetabular cup had been inserted with cement. A random-coefficients prediction algorithm was invoked to estimate long-term wear (mean late rate of wear for the cohort, 0.087 millimeter per year at a mean of 118 months after the operation) on the basis of measurements of short-term wear (mean early rate of wear for the cohort, 0.154 millimeter per year at a mean of twenty-four months).

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9160941     DOI: 10.2106/00004623-199705000-00008

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  12 in total

Review 1.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Long-term radiographic assessment of cemented polyethylene acetabular cups.

Authors:  Sophie Williams; Graham Isaac; Neil Porter; John Fisher; John Older
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

3.  A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Authors:  Bertram The; Gunnar Flivik; Ron L Diercks; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

Review 4.  What are the current clinical issues in wear and tribocorrosion?

Authors:  Daniel J Berry; Matthew P Abdel; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

5.  Cemented total hip replacement cable debris and acetabular construct durability.

Authors:  Aaron J Altenburg; John J Callaghan; Tameem M Yehyawi; Douglas R Pedersen; Steve S Liu; Jessica A Leinen; Kevin A Dahl; Devon D Goetz; Thomas D Brown; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2009-07       Impact factor: 5.284

6.  Clinical biomechanics of wear in total hip arthroplasty.

Authors:  John J Callaghan; Douglas R Pedersen; Richard C Johnston; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2003

Review 7.  2009 Nicolas Andry Award: clinical biomechanics of third body acceleration of total hip wear.

Authors:  Thomas D Brown; Hannah J Lundberg; Douglas R Pedersen; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2009-04-28       Impact factor: 4.176

8.  Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data.

Authors:  R Kosak; V Antolic; V Pavlovcic; V Kralj-Iglic; I Milosev; G Vidmar; A Iglic
Journal:  Skeletal Radiol       Date:  2003-09-13       Impact factor: 2.199

9.  Which functional assessments predict long-term wear after total hip arthroplasty?

Authors:  Ryan K Takenaga; John J Callaghan; Nicholas A Bedard; Steve S Liu; Yubo Gao
Journal:  Clin Orthop Relat Res       Date:  2013-04-09       Impact factor: 4.176

10.  THR Simulator--the software for generating radiographs of THR prosthesis.

Authors:  Tai-Yin Wu; Rong-Sen Yang; Chiou-Shann Fuh; Sheng-Mou Hou; Chen-Kun Liaw
Journal:  BMC Musculoskelet Disord       Date:  2009-01-16       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.