Literature DB >> 18264857

A new method to make 2-D wear measurements less sensitive to projection differences of cemented THAs.

Bertram The1, Gunnar Flivik, Ron L Diercks, Nico Verdonschot.   

Abstract

Wear curves from individual patients often show unexplained irregular wear curves or impossible values (negative wear). We postulated errors of two-dimensional wear measurements are mainly the result of radiographic projection differences. We tested a new method that makes two-dimensional wear measurements less sensitive for radiograph projection differences of cemented THAs. The measurement errors that occur when radiographically projecting a three-dimensional THA were modeled. Based on the model, we developed a method to reduce the errors, thus approximating three-dimensional linear wear values, which are less sensitive for projection differences. An error analysis was performed by virtually simulating 144 wear measurements under varying conditions with and without application of the correction: the mean absolute error was reduced from 1.8 mm (range, 0-4.51 mm) to 0.11 mm (range, 0-0.27 mm). For clinical validation, radiostereometric analysis was performed on 47 patients to determine the true wear at 1, 2, and 5 years. Subsequently, wear was measured on conventional radiographs with and without the correction: the overall occurrence of errors greater than 0.2 mm was reduced from 35% to 15%. Wear measurements are less sensitive to differences in two-dimensional projection of the THA when using the correction method.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18264857      PMCID: PMC2505227          DOI: 10.1007/s11999-007-0077-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  Comparison of two digital radiostereometric analysis methods in the determination of femoral head penetration in a total hip replacement phantom.

Authors:  Charles R Bragdon; Daniel M Estok; Henrik Malchau; Johan Kärrholm; Xunhua Yuan; Robert Bourne; Jean Veldhoven; William H Harris
Journal:  J Orthop Res       Date:  2004-05       Impact factor: 3.494

2.  Correction of error in two-dimensional wear measurements of cemented hip arthroplasties.

Authors:  Bertram The; Linda Mol; Ron L Diercks; Peter M A van Ooijen; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2006-01       Impact factor: 4.176

3.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

4.  Roentgen stereophotogrammetric analysis using computer-based image-analysis.

Authors:  S E Ostgaard; L Gottlieb; S Toksvig-Larsen; A Lebech; A Talbot; B Lund
Journal:  J Biomech       Date:  1997-09       Impact factor: 2.712

5.  Prosthetic hip failure: retrospective radiograph image analysis of the acetabular cup.

Authors:  P R Jones; C J Taylor; D W Hukins; M L Porter; K Hardinge
Journal:  J Biomed Eng       Date:  1989-05

6.  Anteversion of the acetabular cup. Measurement of angle after total hip replacement.

Authors:  M K Ackland; W B Bourne; H K Uhthoff
Journal:  J Bone Joint Surg Br       Date:  1986-05

7.  Silane crosslinked polyethylene for prosthetic applications. II. Creep and wear behaviour and a preliminary moulding test.

Authors:  J R Atkinson; R Z Cicek
Journal:  Biomaterials       Date:  1984-11       Impact factor: 12.479

Review 8.  Radiographic assessment of cup migration and wear after hip replacement.

Authors:  T Ilchmann
Journal:  Acta Orthop Scand Suppl       Date:  1997-10

Review 9.  Wear and osteolysis in total joint replacements.

Authors:  Y Kadoya; A Kobayashi; H Ohashi
Journal:  Acta Orthop Scand Suppl       Date:  1998-02

10.  Prediction of long-term polyethylene wear in total hip arthroplasty, based on early wear measurements made using digital image analysis.

Authors:  D R Pedersen; T D Brown; S L Hillis; J J Callaghan
Journal:  J Orthop Res       Date:  1998-09       Impact factor: 3.494

View more
  5 in total

1.  Polyethylene wear is related to patient-specific contact stress in THA.

Authors:  Robert Košak; Veronika Kralj-Iglič; Aleš Iglič; Matej Daniel
Journal:  Clin Orthop Relat Res       Date:  2011-09-24       Impact factor: 4.176

2.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

3.  Wear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial.

Authors:  Hugo C van der Veen; Inge van den Akker-Scheek; Sjoerd K Bulstra; Jos Jam van Raay
Journal:  BMC Musculoskelet Disord       Date:  2012-09-20       Impact factor: 2.362

Review 4.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

5.  Correction of radiographic measurements of acetabular cup wear for variations in pelvis orientation.

Authors:  Brian Derbyshire
Journal:  Proc Inst Mech Eng H       Date:  2018-02-23       Impact factor: 1.617

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.