Literature DB >> 9156236

The "proper" binormal model: parametric receiver operating characteristic curve estimation with degenerate data.

X Pan1, C E Metz.   

Abstract

RATIONALE AND
OBJECTIVES: The authors assessed the use of a "proper" binormal model and a new algorithm for maximum-likelihood estimation of receiver operating characteristic (ROC) curves from degenerate data.
METHODS: The proper binormal ROC model uses as its decision variable a monotonic transformation of the likelihood ratio that is associated with a pair of normal distributions, thereby ensuring fitted ROC curves with monotonic slope but maintaining a relationship with the conventional binormal model. A computer program entitled PROPROC was used to fit proper ROC curves to data obtained from computer-simulated and real observer studies.
RESULTS: ROC indexes such as total area were estimated with PROPROC and compared with the corresponding values obtained from the conventional procedures.
CONCLUSION: The proper binormal ROC model overcomes the problem of degeneracy in ROC curve fitting. PROPROC is highly robust and yields ROC estimates with less bias and greater precision than those obtained with the conventional binormal model.

Mesh:

Year:  1997        PMID: 9156236     DOI: 10.1016/s1076-6332(97)80121-3

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  29 in total

Review 1.  ROC analysis in medical imaging: a tutorial review of the literature.

Authors:  Charles E Metz
Journal:  Radiol Phys Technol       Date:  2007-10-27

2.  Verification of modified receiver-operating characteristic software using simulated rating data.

Authors:  Junji Shiraishi; Daisuke Fukuoka; Reimi Iha; Haruka Inada; Rie Tanaka; Takeshi Hara
Journal:  Radiol Phys Technol       Date:  2018-09-22

3.  Do long radiology workdays affect nodule detection in dynamic CT interpretation?

Authors:  Elizabeth A Krupinski; Kevin S Berbaum; Robert T Caldwell; Kevin M Schartz; Mark T Madsen; David J Kramer
Journal:  J Am Coll Radiol       Date:  2012-03       Impact factor: 5.532

4.  Computer-aided diagnosis for detection of lacunar infarcts on MR images: ROC analysis of radiologists' performance.

Authors:  Yoshikazu Uchiyama; Takahiko Asano; Hiroki Kato; Takeshi Hara; Masayuki Kanematsu; Hiroaki Hoshi; Toru Iwama; Hiroshi Fujita
Journal:  J Digit Imaging       Date:  2012-08       Impact factor: 4.056

5.  Using the mean-to-sigma ratio as a measure of the improperness of binormal ROC curves.

Authors:  Stephen L Hillis; Kevin S Berbaum
Journal:  Acad Radiol       Date:  2011-02       Impact factor: 3.173

6.  Power estimation for multireader ROC methods an updated and unified approach.

Authors:  Stephen L Hillis; Nancy A Obuchowski; Kevin S Berbaum
Journal:  Acad Radiol       Date:  2011-02       Impact factor: 3.173

7.  Long radiology workdays reduce detection and accommodation accuracy.

Authors:  Elizabeth A Krupinski; Kevin S Berbaum; Robert T Caldwell; Kevin M Schartz; John Kim
Journal:  J Am Coll Radiol       Date:  2010-09       Impact factor: 5.532

8.  Reliable and computationally efficient maximum-likelihood estimation of "proper" binormal ROC curves.

Authors:  Lorenzo L Pesce; Charles E Metz
Journal:  Acad Radiol       Date:  2007-07       Impact factor: 3.173

9.  Operating characteristics predicted by models for diagnostic tasks involving lesion localization.

Authors:  D P Chakraborty; Hong-Jun Yoon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

10.  Using computer-extracted image phenotypes from tumors on breast magnetic resonance imaging to predict breast cancer pathologic stage.

Authors:  Elizabeth S Burnside; Karen Drukker; Hui Li; Ermelinda Bonaccio; Margarita Zuley; Marie Ganott; Jose M Net; Elizabeth J Sutton; Kathleen R Brandt; Gary J Whitman; Suzanne D Conzen; Li Lan; Yuan Ji; Yitan Zhu; Carl C Jaffe; Erich P Huang; John B Freymann; Justin S Kirby; Elizabeth A Morris; Maryellen L Giger
Journal:  Cancer       Date:  2015-11-30       Impact factor: 6.860

View more