Literature DB >> 21232681

Power estimation for multireader ROC methods an updated and unified approach.

Stephen L Hillis1, Nancy A Obuchowski, Kevin S Berbaum.   

Abstract

RATIONALE AND
OBJECTIVES: We describe a step-by-step procedure for estimating power and sample size for planned multireader receiver operating characteristic (ROC) studies that will be analyzed using either the Dorfman-Berbaum-Metz (DBM) or Obuchowski-Rockette (OR) method. This procedure updates previous approaches by incorporating recent methodological developments and unifies the approaches by allowing inputs to be conjectured parameter values or outputs from either a DBM or OR pilot-study analysis.
MATERIALS AND METHODS: Power computations are described in a step-by-step procedure and the theoretical basis for the procedure is described. Updates include using the currently recommended denominator degrees of freedom, accounting for different pilot and planned study normal-to-abnormal case ratios, and a new method for computing the OR test-by-reader variance component.
RESULTS: Using a real dataset we illustrate how to compute the power for two planned studies, one having the same normal-to-abnormal case ratio as the pilot study and the other having a different ratio. In a simulation study, we show that the proposed procedure gives mean power estimates close to the true power.
CONCLUSIONS: Application of the updated procedure is straightforward. It is important that pilot data be comparable to the planned study with respect to the modalities, reader expertise, and case selection. Variability of the power estimates warrants further investigation. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21232681      PMCID: PMC3053069          DOI: 10.1016/j.acra.2010.09.007

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  15 in total

1.  "Proper" Binormal ROC Curves: Theory and Maximum-Likelihood Estimation.

Authors: 
Journal:  J Math Psychol       Date:  1999-03       Impact factor: 2.223

2.  Power estimation for the Dorfman-Berbaum-Metz method.

Authors:  Stephen L Hillis; Kevin S Berbaum
Journal:  Acad Radiol       Date:  2004-11       Impact factor: 3.173

3.  A comparison of denominator degrees of freedom methods for multiple observer ROC analysis.

Authors:  Stephen L Hillis
Journal:  Stat Med       Date:  2007-02-10       Impact factor: 2.373

4.  Recent developments in the Dorfman-Berbaum-Metz procedure for multireader ROC study analysis.

Authors:  Stephen L Hillis; Kevin S Berbaum; Charles E Metz
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

5.  Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices.

Authors:  N A Obuchowski; D K McClish
Journal:  Stat Med       Date:  1997-07-15       Impact factor: 2.373

6.  The "proper" binormal model: parametric receiver operating characteristic curve estimation with degenerate data.

Authors:  X Pan; C E Metz
Journal:  Acad Radiol       Date:  1997-05       Impact factor: 3.173

7.  Dorfman-Berbaum-Metz method for statistical analysis of multireader, multimodality receiver operating characteristic data: validation with computer simulation.

Authors:  C A Roe; C E Metz
Journal:  Acad Radiol       Date:  1997-04       Impact factor: 3.173

8.  Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach.

Authors:  E R DeLong; D M DeLong; D L Clarke-Pearson
Journal:  Biometrics       Date:  1988-09       Impact factor: 2.571

9.  Computing sample size for receiver operating characteristic studies.

Authors:  N A Obuchowski
Journal:  Invest Radiol       Date:  1994-02       Impact factor: 6.016

10.  The meaning and use of the area under a receiver operating characteristic (ROC) curve.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1982-04       Impact factor: 11.105

View more
  20 in total

1.  Multireader multicase reader studies with binary agreement data: simulation, analysis, validation, and sizing.

Authors:  Weijie Chen; Adam Wunderlich; Nicholas Petrick; Brandon D Gallas
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-04

2.  Evaluation of computer-aided detection and diagnosis systems.

Authors:  Nicholas Petrick; Berkman Sahiner; Samuel G Armato; Alberto Bert; Loredana Correale; Silvia Delsanto; Matthew T Freedman; David Fryd; David Gur; Lubomir Hadjiiski; Zhimin Huo; Yulei Jiang; Lia Morra; Sophie Paquerault; Vikas Raykar; Frank Samuelson; Ronald M Summers; Georgia Tourassi; Hiroyuki Yoshida; Bin Zheng; Chuan Zhou; Heang-Ping Chan
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

3.  Generalized Roe and Metz receiver operating characteristic model: analytic link between simulated decision scores and empirical AUC variances and covariances.

Authors:  Brandon D Gallas; Stephen L Hillis
Journal:  J Med Imaging (Bellingham)       Date:  2014-09-25

4.  Diagnostic Assessment of Deep Learning Algorithms for Detection of Lymph Node Metastases in Women With Breast Cancer.

Authors:  Babak Ehteshami Bejnordi; Mitko Veta; Paul Johannes van Diest; Bram van Ginneken; Nico Karssemeijer; Geert Litjens; Jeroen A W M van der Laak; Meyke Hermsen; Quirine F Manson; Maschenka Balkenhol; Oscar Geessink; Nikolaos Stathonikos; Marcory Crf van Dijk; Peter Bult; Francisco Beca; Andrew H Beck; Dayong Wang; Aditya Khosla; Rishab Gargeya; Humayun Irshad; Aoxiao Zhong; Qi Dou; Quanzheng Li; Hao Chen; Huang-Jing Lin; Pheng-Ann Heng; Christian Haß; Elia Bruni; Quincy Wong; Ugur Halici; Mustafa Ümit Öner; Rengul Cetin-Atalay; Matt Berseth; Vitali Khvatkov; Alexei Vylegzhanin; Oren Kraus; Muhammad Shaban; Nasir Rajpoot; Ruqayya Awan; Korsuk Sirinukunwattana; Talha Qaiser; Yee-Wah Tsang; David Tellez; Jonas Annuscheit; Peter Hufnagl; Mira Valkonen; Kimmo Kartasalo; Leena Latonen; Pekka Ruusuvuori; Kaisa Liimatainen; Shadi Albarqouni; Bharti Mungal; Ami George; Stefanie Demirci; Nassir Navab; Seiryo Watanabe; Shigeto Seno; Yoichi Takenaka; Hideo Matsuda; Hady Ahmady Phoulady; Vassili Kovalev; Alexander Kalinovsky; Vitali Liauchuk; Gloria Bueno; M Milagro Fernandez-Carrobles; Ismael Serrano; Oscar Deniz; Daniel Racoceanu; Rui Venâncio
Journal:  JAMA       Date:  2017-12-12       Impact factor: 56.272

5.  A Feasibility Study of Smartphone-Based Telesonography for Evaluating Cardiac Dynamic Function and Diagnosing Acute Appendicitis with Control of the Image Quality of the Transmitted Videos.

Authors:  Changsun Kim; Hyunmin Cha; Bo Seung Kang; Hyuk Joong Choi; Tae Ho Lim; Jaehoon Oh
Journal:  J Digit Imaging       Date:  2016-06       Impact factor: 4.056

6.  A Feasibility Study of Real-Time Remote CT Reading for Suspected Acute Appendicitis Using an iPhone.

Authors:  Changsun Kim; Bossng Kang; Hyuk Joong Choi; Joon Bum Park
Journal:  J Digit Imaging       Date:  2015-08       Impact factor: 4.056

7.  Simulation of unequal-variance binormal multireader ROC decision data: an extension of the Roe and Metz simulation model.

Authors:  Stephen L Hillis
Journal:  Acad Radiol       Date:  2012-12       Impact factor: 3.173

8.  Multi-reader ROC studies with split-plot designs: a comparison of statistical methods.

Authors:  Nancy A Obuchowski; Brandon D Gallas; Stephen L Hillis
Journal:  Acad Radiol       Date:  2012-12       Impact factor: 3.173

9.  Demonstration of Multi- and Single-Reader Sample Size Program for Diagnostic Studies software.

Authors:  Stephen L Hillis; Kevin M Schartz
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-17

10.  Comparative statistical properties of expected utility and area under the ROC curve for laboratory studies of observer performance in screening mammography.

Authors:  Craig K Abbey; Brandon D Gallas; John M Boone; Loren T Niklason; Lubomir M Hadjiiski; Berkman Sahiner; Frank W Samuelson
Journal:  Acad Radiol       Date:  2014-04       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.