Literature DB >> 8928309

Thresholds for ultrasonically induced lung hemorrhage in neonatal swine.

R Baggs1, D P Penney, C Cox, S Z Child, C H Raeman, D Dalecki, E L Carstensen.   

Abstract

The threshold for generation of lung hemorrhage in adult mice by pulsed ultrasound has been shown to be approximately 1 MPa at the surface of the lung (10-microseconds pulse and a carrier frequency of 2 MHz). This investigation used neonatal swine to determine if the findings for mice can be generalized to other species. After exploratory observations, the inverse sampling method was used in a primary study (22 animals, 88 exposure sites) to determine the threshold for lung hemorrhage in neonatal swine. The primary study was followed by a separate confirmation study (13 animals, 48 exposure sites), testing the conclusions of the first study and comparing damage at subthreshold levels with sham-exposed animals. A separate investigation explored the histological nature of tissue damage at suprathreshold levels. A 2.3-MHz focused transducer (10 microseconds at 100-Hz pulse-repetition frequency) was incremented vertically for a distance of 2 cm over the chest of the subject for a total exposure period of 16 min. Animals were euthanized and lungs were scored by visual inspection for numbers and areas of gross hemorrhages. The threshold level for hemorrhage was approximately 1.5 MPa peak positive pressure in water at the surface of the animal or, at the surface of the lung, 1.1 MPa peak positive pressure, 1 MPa fundamental pressure, 0.9 MPa maximum negative pressure, 25 W cm-2 pulse average intensity or a mechanical index of 0.6. These values are essentially the same as those reported for adult mice.

Entities:  

Mesh:

Year:  1996        PMID: 8928309     DOI: 10.1016/0301-5629(95)02035-7

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  15 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

5.  Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson; Leon A Frizzell; Rita J Miller; James P Blue; James F Zachary
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

Review 6.  Ultrasound-biophysics mechanisms.

Authors:  William D O'Brien
Journal:  Prog Biophys Mol Biol       Date:  2006-08-08       Impact factor: 3.667

7.  Evaluation of the threshold for lung hemorrhage by diagnostic ultrasound and a proposed new safety index.

Authors:  Charles C Church; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2007-03-26       Impact factor: 2.998

8.  Superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.

Authors:  William D O'Brien; Douglas G Simpson; Leon A Frizzell; James F Zachary
Journal:  J Ultrasound Med       Date:  2006-07       Impact factor: 2.153

9.  Ultrasonic imaging: safety considerations.

Authors:  Gail Ter Haar
Journal:  Interface Focus       Date:  2011-05-25       Impact factor: 3.906

10.  Transoesophageal echocardiography related complications.

Authors:  S K Mathur; Pooja Singh
Journal:  Indian J Anaesth       Date:  2009-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.