Superthreshold behavior of ultrasound-induced lung hemorrhage in adult rats: role of pulse repetition frequency and pulse duration.

William D O'Brien1, Douglas G Simpson, Leon A Frizzell, James F Zachary.   

Abstract

OBJECTIVE: The purpose of this study was to enhance the findings of an earlier ultrasound-induced lung hemorrhage study (Ultrasound Med Biol 2003; 29:1625-1634) that estimated pressure thresholds as a function of pulse duration (PD: 1.3, 4.4, 8.2, and 11.6 micros; 2.8 MHz; 10-s exposure duration [ED]; 1-kHz pulse repetition frequency [PRF]). In this study, the roles of PRF and PD were evaluated at 5.9 MPa, the peak rarefactional pressure threshold near that of the ED50 estimate previously determined.
METHODS: A 4 x 4 factorial design study (PRF: 50, 170, 500, and 1700 Hz; PD: 1.3, 4.4, 8.2, and 11.6 mus) was conducted (2.8 MHz; 10-s ED). Sprague Dawley rats (n = 175) were divided into 16 exposure groups (10 rats per group) and 1 sham group (15 rats); no lesions were produced in the sham group. Logistic regression analysis evaluated significance of effects for lesion occurrence, and Gaussian tobit analysis evaluated significance for lesion depth and surface area.
RESULTS: For lesion occurrence and sizes, the main effect of PRF was not significant. The interaction term, PRF x PD, was highly significant, indicating a strong positive dependence of lesion occurrence on the duty factor. The main effect of PD was almost significant (P = .052) and thus was included in the analysis model for a better fit.
CONCLUSIONS: Compared with the findings from a PRF x ED factorial study (J Ultrasound Med 2005; 24:339-348), a function that considers PRF, PD, and ED might yield a sensitive indicator for consideration of a modified mechanical index, at least for the lung.

Entities:  

Mesh:

Year:  2006        PMID: 16798898      PMCID: PMC1994937          DOI: 10.7863/jum.2006.25.7.873

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  27 in total

1.  Lung damage from exposure to pulsed ultrasound.

Authors:  S Z Child; C L Hartman; L A Schery; E L Carstensen
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

2.  Superthreshold behavior of ultrasound-induced lung hemorrhage in adult mice and rats: role of pulse repetition frequency and exposure duration.

Authors:  W D O'Brien; L A Frizzell; D J Schaeffer; J F Zachary
Journal:  Ultrasound Med Biol       Date:  2001-02       Impact factor: 2.998

3.  Thresholds for ultrasonically induced lung hemorrhage in neonatal swine.

Authors:  R Baggs; D P Penney; C Cox; S Z Child; C H Raeman; D Dalecki; E L Carstensen
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

4.  Exposure-time dependence of the threshold for ultrasonically induced murine lung hemorrhage.

Authors:  C H Raeman; S Z Child; D Dalecki; C Cox; E L Carstensen
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

5.  Superthreshold behavior and threshold estimation of ultrasound-induced lung hemorrhage in adult mice and rats.

Authors:  J F Zachary; J M Sempsrott; L A Frizzell; D G Simpson; W D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-03       Impact factor: 2.725

6.  Ultrasound-induced lung hemorrhage: role of acoustic boundary conditions at the pleural surface.

Authors:  William D O'Brien; Jeffrey M Kramer; Tony G Waldrop; Leon A Frizzell; Rita J Miller; James P Blue; James F Zachary
Journal:  J Acoust Soc Am       Date:  2002-02       Impact factor: 1.840

7.  Ultrasound-induced lung hemorrhage is not caused by inertial cavitation.

Authors:  W D O'Brien; L A Frizzell; R M Weigel; J F Zachary
Journal:  J Acoust Soc Am       Date:  2000-09       Impact factor: 1.840

8.  Ultrasound-induced lung hemorrhage in the monkey.

Authors:  A F Tarantal; D R Canfield
Journal:  Ultrasound Med Biol       Date:  1994       Impact factor: 2.998

9.  Lung lesions induced by continuous- and pulsed-wave (diagnostic) ultrasound in mice, rabbits, and pigs.

Authors:  J F Zachary; W D O'Brien
Journal:  Vet Pathol       Date:  1995-01       Impact factor: 2.221

10.  Morphological effects of pulsed ultrasound in the lung.

Authors:  D P Penney; E A Schenk; K Maltby; C Hartman-Raeman; S Z Child; E L Carstensen
Journal:  Ultrasound Med Biol       Date:  1993       Impact factor: 2.998

View more
  7 in total

1.  Evaluation of the threshold for lung hemorrhage by diagnostic ultrasound and a proposed new safety index.

Authors:  Charles C Church; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2007-03-26       Impact factor: 2.998

2.  Blood-brain barrier disruption induced by focused ultrasound and circulating preformed microbubbles appears to be characterized by the mechanical index.

Authors:  Nathan McDannold; Natalia Vykhodtseva; Kullervo Hynynen
Journal:  Ultrasound Med Biol       Date:  2008-01-22       Impact factor: 2.998

3.  Ultrasonic imaging: safety considerations.

Authors:  Gail Ter Haar
Journal:  Interface Focus       Date:  2011-05-25       Impact factor: 3.906

4.  Anesthetic techniques influence the induction of pulmonary capillary hemorrhage during diagnostic ultrasound scanning in rats.

Authors:  Douglas L Miller; Chunyan Dou; Krishnan Raghavendran
Journal:  J Ultrasound Med       Date:  2015-02       Impact factor: 2.153

5.  Threshold estimation and superthreshold behavior of ultrasound-induced lung hemorrhage in rats: role of age dependency.

Authors:  William D O'Brien; Yan Yang; Douglas G Simpson
Journal:  Ultrasound Med Biol       Date:  2008-09-03       Impact factor: 2.998

6.  Experimental Measurements of Ultrasound Attenuation in Human Chest Wall and Assessment of the Mechanical Index for Lung Ultrasound.

Authors:  Brandon Patterson; Douglas L Miller
Journal:  Ultrasound Med Biol       Date:  2020-03-24       Impact factor: 2.998

7.  Safe and Effective Treatment of Compromised Clavicle Fracture of the Medial and Lateral Third Using Focused Shockwaves.

Authors:  Rainer Mittermayr; Nicolas Haffner; Sebastian Eder; Jonas Flatscher; Wolfgang Schaden; Paul Slezak; Cyrill Slezak
Journal:  J Clin Med       Date:  2022-04-02       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.