Literature DB >> 8800870

The imaging performance of a storage phosphor system for dental radiography.

D S Brettle1, A Workman, R P Ellwood, J H Launders, K Horner, R M Davies.   

Abstract

Direct digital imaging systems are becoming increasingly common in dental radiography. The majority of these systems are based on charge coupled device (CCD) technology. A relatively new system, based on photo-stimulable phosphor luminescence (PSPL), is now commercially available. This system appears to overcome some of the restrictions of CCD systems including those associated with the bulky detector, connecting wire, limited image size and limited exposure latitude. A physical evaluation of the PSPL system was conducted including measurements of sensitometric response, modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). These measurements were compared with results obtained previously for Kodak Ektaspeed (E-speed) film. The results of the evaluation indicate that the PSPL system may be capable of operating at exposures up to 80% lower than for film with comparable image quality.

Entities:  

Mesh:

Year:  1996        PMID: 8800870     DOI: 10.1259/0007-1285-69-819-256

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  9 in total

1.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 1: the influence of X-ray generator on periodontal measurements using conventional and digital receptors.

Authors:  Bart Vandenberghe; Livia Corpas; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-05       Impact factor: 3.573

2.  A comprehensive in vitro study of image accuracy and quality for periodontal diagnosis. Part 2: the influence of intra-oral image receptor on periodontal measurements.

Authors:  Bart Vandenberghe; Hilde Bosmans; Jie Yang; Reinhilde Jacobs
Journal:  Clin Oral Investig       Date:  2010-05-12       Impact factor: 3.573

3.  Relationship between radiation dose reduction and image quality change in photostimulable phosphor luminescence X-ray imaging systems.

Authors:  T Sakurai; R Kawamata; Y Kozai; Y Kaku; K Nakamura; M Saito; H Wakao; I Kashima
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

4.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

5.  A comparative study on image quality of two digital intraoral sensors.

Authors:  Cinar Aziman; Kristina Hellén-Halme; Xie-Qi Shi
Journal:  Dentomaxillofac Radiol       Date:  2019-05-14       Impact factor: 2.419

6.  Influence of the display monitor on observer performance in detection of dental caries.

Authors:  Farzad Esmaeili; Esrafil Balaei; Firoz Pouralibaba; Farzaneh Kaviani; Atabak Kashefimehr
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2007-09-10

7.  Evaluation of the effects of processing delays and protective plastic cases on image quality of a photostimulable phosphor plate system.

Authors:  Clóvis Monteiro Bramante; Alexandre Silva Bramante; Rogério Emílio de Souza; Ivaldo Gomes Moraes; Norberti Bernardineli; Roberto Brandão Garcia
Journal:  J Appl Oral Sci       Date:  2008 Sep-Oct       Impact factor: 2.698

8.  Practical considerations for noise power spectra estimation for clinical CT scanners.

Authors:  Steven Dolly; Hsin-Chen Chen; Mark Anastasio; Sasa Mutic; Hua Li
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

9.  The influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor.

Authors:  Bart Vandenberghe; Reinhilde Jacobs
Journal:  J Oral Maxillofac Res       Date:  2010-04-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.