Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator.

M Yukihiro1, T Inoue, T Iwasaki, K Tomiyoshi, K Erlandsson, K Endo.   

Abstract

The purpose of this study was to evaluate the accuracy of myocardial imaging by means of high-resolution single-photon emission tomography (SPET) with a pinhole collimator in rats with experimental infarction. Myocardial infarctions were induced in male Wistar rats by ligation of the left coronary artery for 30 min, followed by reperfusion. Two days after the reperfusion, pinhole SPET was performed after the intravenous administration of 111 MBq of thallium-201 chloride, using a rotating gamma camera equipped with a pinhole insert (2.0-mm aperture) in a low-energy pinhole collimator. SPET projection data were collected at 6 degrees increments over 360 degrees using a 4-cm radius of rotation to reconstruct the short- and long-axis images. Projection data were acquired in 15 or 30 s, the SPET imaging being accomplished within 40 min after the injection of 201Tl. After SPET, the rats were sacrificed to remove the hearts for autoradiography (ARG) and nitroblue tetrazolium (NBT) staining as a visual correlative study. Quantitative correlative studies between pinhole SPET and ARG were performed with linear regression analysis for infarct size and distribution properties (relative counts on SPET images and relative density on autoradiographs) on the short-axis sections. All infarcts (4 mm in minimum diameter) in seven rats were detected by pinhole SPET. The SPET images in rats with or without myocardial infarction were consistent with the findings of ARG and NBT staining. There were significant correlations between pinhole SPET and ARG with respect to the infarct size (r=0.933, P <0.001; n=15) and the relative radiotracer distribution (r=0.931, P <0.001; n=68). This study therefore confirmed the accuracy of myocardial pinhole SPET imaging in rats with myocardial infarction. This method may partially substitute for ARG and prove useful for assessing new myocardial imaging agents in vivo in small laboratory animals.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8753677     DOI: 10.1007/bf01084362

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  8 in total

1.  Macroscopic identification of early myocardial infarcts by alterations in dehydrogenase activity.

Authors:  M M NACHLAS; T K SHNITKA
Journal:  Am J Pathol       Date:  1963-04       Impact factor: 4.307

2.  Simple techniques for the surgical occlusion of coronary vessels in the rat.

Authors:  H SELYE; E BAJUSZ; S GRASSO; P MENDELL
Journal:  Angiology       Date:  1960-10       Impact factor: 3.619

3.  Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT.

Authors:  R J Jaszczak; J Li; H Wang; M R Zalutsky; R E Coleman
Journal:  Phys Med Biol       Date:  1994-03       Impact factor: 3.609

4.  Pinhole emission computed tomography: method and experimental evaluation.

Authors:  J Palmer; P Wollmer
Journal:  Phys Med Biol       Date:  1990-03       Impact factor: 3.609

5.  Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals.

Authors:  D A Weber; M Ivanovic; D Franceschi; S E Strand; K Erlandsson; M Franceschi; H L Atkins; J A Coderre; H Susskind; T Button
Journal:  J Nucl Med       Date:  1994-02       Impact factor: 10.057

6.  Ultra-high resolution SPECT system using four pinhole collimators for small animal studies.

Authors:  K Ishizu; T Mukai; Y Yonekura; M Pagani; T Fujita; Y Magata; S Nishizawa; N Tamaki; H Shibasaki; J Konishi
Journal:  J Nucl Med       Date:  1995-12       Impact factor: 10.057

7.  High-resolution PET imaging and quantitation of pharmaceutical biodistributions in a small animal using avalanche photodiode detectors.

Authors:  C J Marriott; J E Cadorette; R Lecomte; V Scasnar; J Rousseau; J E van Lier
Journal:  J Nucl Med       Date:  1994-08       Impact factor: 10.057

8.  The effect of coronary artery reperfusion on the extent of myocardial infarction.

Authors:  A Deloche; J N Fabiani; J P Camilleri; J Relland; D Joseph; A Carpentier; C Dubost
Journal:  Am Heart J       Date:  1977-03       Impact factor: 4.749

  8 in total
  10 in total

Review 1.  Ultra-high-resolution imaging of small animals: implications for preclinical and research studies.

Authors:  D A Weber; M Ivanovic
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

2.  An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

Authors:  Qiulin Tang; Gengsheng L Zeng; Qiu Huang
Journal:  Phys Med Biol       Date:  2006-11-09       Impact factor: 3.609

3.  Resolution recovery in pinhole SPECT based on multi-ray projections: a phantom study.

Authors:  Christian Vanhove; Andriy Andreyev; Michel Defrise; Johan Nuyts; Axel Bossuyt
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-09-05       Impact factor: 9.236

Review 4.  Monitoring left ventricular function in small animals.

Authors:  Tony Lahoutte
Journal:  J Nucl Cardiol       Date:  2007 May-Jun       Impact factor: 5.952

5.  Myocardial perfusion imaging is feasible for infarct size quantification in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators.

Authors:  Tim Wollenweber; Christian Zach; Christoph Rischpler; Rebekka Fischer; Sebastian Nowak; Stephan G Nekolla; Michael Gröbner; Christopher Ubleis; Gerald Assmann; Josef Müller-Höcker; Christian La Fougére; Guido Böning; Paul Cumming; Wolfgang-Michael Franz; Marcus Hacker
Journal:  Mol Imaging Biol       Date:  2009-11-25       Impact factor: 3.488

6.  Evaluation of myocardial infarct size in rat heart by pinhole SPECT.

Authors:  T Hirai; R Nohara; R Hosokawa; M Tanaka; H Inada; Y Fujibayashi; M Fujita; J Konishi; S Sasayama
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

Review 7.  Use of tomographic nuclear medicine procedures, SPECT and pinhole SPECT, with cationic lipophilic radiotracers for the evaluation of axillary lymph node status in breast cancer patients.

Authors:  Giuseppe Madeddu; Angela Spanu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

8.  Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; George A Kastis; Gail D Stevenson; Harrison H Barrett; Lars R Furenlid; Matthew A Kupinski; Dennis D Patton; Donald W Wilson
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

9.  Cardiac Radionuclide Imaging in Rodents: A Review of Methods, Results, and Factors at Play.

Authors:  Francesco Cicone; David Viertl; Ana Maria Quintela Pousa; Thibaut Denoël; Silvano Gnesin; Francesco Scopinaro; Marie-Catherine Vozenin; John O Prior
Journal:  Front Med (Lausanne)       Date:  2017-03-29

10.  Impact of injection dose, post-reconstruction filtering, and collimator choice on image quality of myocardial perfusion SPECT using cadmium-zinc telluride detectors in the rat.

Authors:  Asuka Mizutani; Ichiro Matsunari; Masato Kobayashi; Kodai Nishi; Wataru Fujita; Yoshiharu Miyazaki; Stephan G Nekolla; Keiichi Kawai
Journal:  EJNMMI Phys       Date:  2015-03-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.