Literature DB >> 19937392

Myocardial perfusion imaging is feasible for infarct size quantification in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators.

Tim Wollenweber1, Christian Zach, Christoph Rischpler, Rebekka Fischer, Sebastian Nowak, Stephan G Nekolla, Michael Gröbner, Christopher Ubleis, Gerald Assmann, Josef Müller-Höcker, Christian La Fougére, Guido Böning, Paul Cumming, Wolfgang-Michael Franz, Marcus Hacker.   

Abstract

INTRODUCTION: The aim of this study is to evaluate a non-invasive method for measuring myocardial perfusion defect size in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators (pinhole SPECT).
MATERIALS AND METHODS: Thirty days after ligation of the left anterior descending coronary artery, 13 mice (C57BL/6J) were imaged following intravenous injection of 370 MBq [99mTc]sestamibi. Eight control mice without myocardial infarction were likewise investigated. Image quality optimization had been achieved by repeated scanning of a multiple point phantom, with varying zoom factors, number of projection angles, and pinhole diameter. Volumetric sampling was used to generate polar maps, in which intensity was normalized to that of a standard septal region of interest (ROI), which was set at 100%. Receiver operating characteristic analyses were performed to define an optimal threshold as compared to histologically measured defect sizes, which were considered as gold standard.
RESULTS: A spatial resolution of 1.9 mm was achieved using a pinhole diameter of 0.5 mm, a zoom factor of 2, and 6 degrees projection angles. Histological results were best reproduced by a 60% threshold relative to the septal reference ROI. By applying this threshold, SPECT perfusion defect sizes revealed very high correlation to the histological results (R(2) = 0.867) with excellent intra- and interobserver reproducibility (intraclass correlation coefficients of 0.84 and 0.82).
CONCLUSIONS: We achieved a spatial resolution of 1.9 mm in myocardial perfusion imaging in mice using a clinical SPECT system mounted with pinhole collimators. Compared to a histological gold standard, the infarct sizes were accurately estimated, indicating that this method shows promise to monitor experimental cardiac interventions in mice.

Entities:  

Mesh:

Year:  2009        PMID: 19937392     DOI: 10.1007/s11307-009-0281-5

Source DB:  PubMed          Journal:  Mol Imaging Biol        ISSN: 1536-1632            Impact factor:   3.488


  21 in total

1.  In vivo visualization of embryonic stem cell survival, proliferation, and migration after cardiac delivery.

Authors:  Feng Cao; Shuan Lin; Xiaoyan Xie; Pritha Ray; Manishkumar Patel; Xianzhong Zhang; Micha Drukker; Scott J Dylla; Andrew J Connolly; Xiaoyuan Chen; Irving L Weissman; Sanjiv S Gambhir; Joseph C Wu
Journal:  Circulation       Date:  2006-02-13       Impact factor: 29.690

2.  Age-dependent changes in oxygen tension, radiation dose and sensitivity within normal and diseased coronary arteries-Part A: dose from radon and thoron.

Authors:  Richard B Richardson
Journal:  Int J Radiat Biol       Date:  2008-10       Impact factor: 2.694

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Evaluation of myocardial infarct size in rat heart by pinhole SPECT.

Authors:  T Hirai; R Nohara; R Hosokawa; M Tanaka; H Inada; Y Fujibayashi; M Fujita; J Konishi; S Sasayama
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

5.  Myocardial infarction in rats: high-resolution single-photon emission tomographic imaging with a pinhole collimator.

Authors:  M Yukihiro; T Inoue; T Iwasaki; K Tomiyoshi; K Erlandsson; K Endo
Journal:  Eur J Nucl Med       Date:  1996-08

6.  Characterization of normal and infarcted rat myocardium using a combination of small-animal PET and clinical MRI.

Authors:  Takahiro Higuchi; Stephan G Nekolla; Antanas Jankaukas; Axel W Weber; Marc C Huisman; Sybille Reder; Sibylle I Ziegler; Markus Schwaiger; Frank M Bengel
Journal:  J Nucl Med       Date:  2007-02       Impact factor: 10.057

7.  In vivo assessment of myocardial blood flow in rat heart using magnetic resonance imaging: effect of anesthesia.

Authors:  Isabelle Iltis; Frank Kober; Christiane Dalmasso; Carole Lan; Patrick J Cozzone; Monique Bernard
Journal:  J Magn Reson Imaging       Date:  2005-08       Impact factor: 4.813

8.  Accurate noninvasive measurement of infarct size in mice with high-resolution PET.

Authors:  Lars Stegger; Anne-Nadine Hoffmeier; Klaus P Schäfers; Sven Hermann; Otmar Schober; Michael A Schäfers; Gregor Theilmeier
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

9.  Quantitative analysis of acute myocardial infarct in rat hearts with ischemia-reperfusion using a high-resolution stationary SPECT system.

Authors:  Zhonglin Liu; George A Kastis; Gail D Stevenson; Harrison H Barrett; Lars R Furenlid; Matthew A Kupinski; Dennis D Patton; Donald W Wilson
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

10.  High-resolution imaging of the large non-human primate brain using microPET: a feasibility study.

Authors:  S Naidoo-Variawa; A J Hey-Cunningham; W Lehnert; P L Kench; M Kassiou; R Banati; S R Meikle
Journal:  Phys Med Biol       Date:  2007-10-26       Impact factor: 3.609

View more
  15 in total

1.  Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT.

Authors:  Adelaide Greco; Maria Piera Petretta; Michele Larobina; Sara Gargiulo; Mariarosaria Panico; Stephan G Nekolla; Giovanni Esposito; Mario Petretta; Arturo Brunetti; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2012-03-07       Impact factor: 5.952

2.  In-vivo monitoring of erythropoietin treatment after myocardial infarction in mice with [⁶⁸Ga]Annexin A5 and [¹⁸F]FDG PET.

Authors:  Andrei Todica; Mathias J Zacherl; Hao Wang; Guido Böning; Nathalie L Jansen; Carmen Wängler; Peter Bartenstein; Michael C Kreissl; Marcus Hacker; Stefan Brunner; Sebastian Lehner
Journal:  J Nucl Cardiol       Date:  2014-09-05       Impact factor: 5.952

Review 3.  Impact of parathyroid hormone on bone marrow-derived stem cell mobilization and migration.

Authors:  Bruno C Huber; Ulrich Grabmaier; Stefan Brunner
Journal:  World J Stem Cells       Date:  2014-11-26       Impact factor: 5.326

4.  [68Ga]-albumin-PET in the monitoring of left ventricular function in murine models of ischemic and dilated cardiomyopathy: comparison with cardiac MRI.

Authors:  Andrei Todica; Stefan Brunner; Guido Böning; Sebastian Lehner; Stephan G Nekolla; Moritz Wildgruber; Christopher Übleis; Carmen Wängler; Martina Sauter; Karin Klingel; Paul Cumming; Peter Bartenstein; Ralf Schirrmacher; Wolfgang Michael Franz; Marcus Hacker
Journal:  Mol Imaging Biol       Date:  2013-08       Impact factor: 3.488

5.  Myocardial infarct size quantification in mice by SPECT using a novel algorithm independent of a normal perfusion database.

Authors:  Véronique Roelants; Marie Delgaudine; Stephan Walrand; Renaud Lhommel; Yves Beguin; François Jamar; Jean-Louis Vanoverschelde
Journal:  EJNMMI Res       Date:  2012-12-28       Impact factor: 3.138

6.  Systematic evaluation of 99mTc-tetrofosmin versus 99mTc-sestamibi to study murine myocardial perfusion in small animal SPECT/CT.

Authors:  Alexis Vrachimis; Sven Hermann; Domokos Máthé; Otmar Schober; Michael Schäfers
Journal:  EJNMMI Res       Date:  2012-05-24       Impact factor: 3.138

Review 7.  PET/CT imaging in mouse models of myocardial ischemia.

Authors:  Sara Gargiulo; Adelaide Greco; Matteo Gramanzini; Maria Piera Petretta; Adele Ferro; Michele Larobina; Mariarosaria Panico; Arturo Brunetti; Alberto Cuocolo
Journal:  J Biomed Biotechnol       Date:  2012-03-13

Review 8.  Advances in pinhole and multi-pinhole collimators for single photon emission computed tomography imaging.

Authors:  Jalil Pirayesh Islamian; AhmadReza Azazrm; Babak Mahmoudian; Esmail Gharapapagh
Journal:  World J Nucl Med       Date:  2015 Jan-Apr

9.  Left ventricular functional assessment in murine models of ischemic and dilated cardiomyopathy using [18 F]FDG-PET: comparison with cardiac MRI and monitoring erythropoietin therapy.

Authors:  Stefan Brunner; Andrei Todica; Guido Böning; Stefan G Nekolla; Moritz Wildgruber; Sebastian Lehner; Martina Sauter; Christopher Ubleis; Karin Klingel; Paul Cumming; Wolfgang Michael Franz; Marcus Hacker
Journal:  EJNMMI Res       Date:  2012-08-03       Impact factor: 3.138

10.  Impact of injection dose, post-reconstruction filtering, and collimator choice on image quality of myocardial perfusion SPECT using cadmium-zinc telluride detectors in the rat.

Authors:  Asuka Mizutani; Ichiro Matsunari; Masato Kobayashi; Kodai Nishi; Wataru Fujita; Yoshiharu Miyazaki; Stephan G Nekolla; Keiichi Kawai
Journal:  EJNMMI Phys       Date:  2015-03-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.