Literature DB >> 18719037

Dose measurement on both patients and operators during neurointerventional procedures using photoluminescence glass dosimeters.

T Moritake1, Y Matsumaru, T Takigawa, K Nishizawa, A Matsumura, K Tsuboi.   

Abstract

BACKGROUND AND
PURPOSE: Although radiation skin injuries associated with interventional radiology have been known as a critical issue, there are few reports mentioning direct measurement of the entrance skin dose (ESD). Thus, the purpose of this study was to clarify the regional distributions of ESDs in neurointervention.
MATERIALS AND METHODS: Using photoluminescence glass dosimeters (PLDs), we measured the ESDs in 32 patients with a median age of 61.5 years. Angiographic parameters, including exposure time, dose-area product (DAP), and the number of digital subtraction angiography (DSA) studies and frames, were recorded. The ESDs of operators were analyzed by the same method.
RESULTS: The maximum ESD of 28 therapeutic procedures was 1.8 +/- 1.3 Gy. Although the averaged ESD on the right temporo-occipital region was higher than that in other regions, disease-specific patterns were not observed. Statistically positive correlations were found between the maximum ESD and exposure time (r = 0.5283, P = .005), DAP (r = 0.7917, P < .001), the number of DSA studies (r = 0.5636, P = .002), and the number of DSA frames (r = 0.8583, P < .001). As for operators, ESDs to the left upper extremity were significantly higher than those to other regions. However, most of the ESDs were <0.2 mGy. Lead protective garments reduced the exposure doses to approximately one half to one tenth.
CONCLUSION: It was shown that the regional ESD could be measured by applying the PLD. This method should contribute to reducing the dose accumulation in patients as well as in operators.

Entities:  

Mesh:

Year:  2008        PMID: 18719037      PMCID: PMC8118939          DOI: 10.3174/ajnr.A1235

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  23 in total

1.  Entrances skin dose distribution maps for interventional neuroradiological procedures: a preliminary study.

Authors:  O Rampado; R Ropolo
Journal:  Radiat Prot Dosimetry       Date:  2006-02-03       Impact factor: 0.972

2.  Radiation exposure during catheter ablation of atrial fibrillation.

Authors:  Lars Lickfett; Mahadevappa Mahesh; Chandra Vasamreddy; David Bradley; Vinod Jayam; Zayd Eldadah; Timm Dickfeld; Deborah Kearney; Darshan Dalal; Berndt Lüderitz; Ronald Berger; Hugh Calkins
Journal:  Circulation       Date:  2004-10-25       Impact factor: 29.690

3.  A study on maximum skin dose in cerebral embolization procedures.

Authors:  L D'Ercole; L Mantovani; F Zappoli Thyrion; M Bocchiola; A Azzaretti; F Di Maria; C Massa Saluzzo; P Quaretti; G Rodolico; P Scagnelli; L Andreucci
Journal:  AJNR Am J Neuroradiol       Date:  2007-03       Impact factor: 3.825

4.  Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure.

Authors:  W Huda; K R Peters
Journal:  Radiology       Date:  1994-12       Impact factor: 11.105

5.  Entrance skin dose estimates derived from dose-area product measurements in interventional radiological procedures.

Authors:  B J McParland
Journal:  Br J Radiol       Date:  1998-12       Impact factor: 3.039

6.  Correlation of patient and staff doses in interventional cardiology.

Authors:  V Tsapaki; S Kottou; E Vano; T Parviainen; R Padovani; A Dowling; M Molfetas; V Neofotistou
Journal:  Radiat Prot Dosimetry       Date:  2006-02-03       Impact factor: 0.972

Review 7.  Lens injuries induced by occupational exposure in non-optimized interventional radiology laboratories.

Authors:  E Vañó; L González; F Beneytez; F Moreno
Journal:  Br J Radiol       Date:  1998-07       Impact factor: 3.039

8.  Patient and staff dosimetry in neuroradiological procedures.

Authors:  N W Marshall; J Noble; K Faulkner
Journal:  Br J Radiol       Date:  1995-05       Impact factor: 3.039

9.  Radiation exposure in endovascular surgery of the head and neck.

Authors:  N Kuwayama; A Takaku; S Endo; M Nishijima; T Kamei
Journal:  AJNR Am J Neuroradiol       Date:  1994-11       Impact factor: 3.825

10.  Radiation doses to patients in neurointerventional procedures.

Authors:  P Bergeron; R Carrier; D Roy; N Blais; J Raymond
Journal:  AJNR Am J Neuroradiol       Date:  1994-11       Impact factor: 3.825

View more
  15 in total

1.  A comparison of radiation exposure between diagnostic CTA and DSA examinations of cerebral and cervicocerebral vessels.

Authors:  A-L Manninen; J-M Isokangas; A Karttunen; T Siniluoto; M T Nieminen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

Review 2.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

3.  Real-time eye lens dose monitoring during cerebral angiography procedures.

Authors:  M J Safari; J H D Wong; K A A Kadir; N K Thorpe; D L Cutajar; M Petasecca; M L F Lerch; A B Rosenfeld; K H Ng
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

4.  A new reference point for patient dose estimation in neurovascular interventional radiology.

Authors:  Kohei Kawasaki; Masaharu Imazeki; Ryota Hasegawa; Shinichi Shiba; Hiroyuki Takahashi; Kazuhiko Sato; Jyoji Ota; Hiroaki Suzuki; Kazuo Awai; Hajime Sakamoto; Osamu Tajima; Atsuko Tsukamoto; Tatsuya Kikuchi; Takahiro Kageyama; Kyoichi Kato
Journal:  Radiol Phys Technol       Date:  2013-04-19

5.  The Efficacy of Shielding Systems for Reducing Operator Exposure during Neurointerventional Procedures: A Real-World Prospective Study.

Authors:  T R Miller; J Zhuo; G Jindal; R Shivashankar; N Beaty; D Gandhi
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

6.  Assessment of organ and effective dose when using region-of-interest attenuators in cone-beam CT and interventional fluoroscopy.

Authors:  Zhenyu Xiong; Sarath Vijayan; Stephen Rudin; Daniel R Bednarek
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-22

Review 7.  What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?

Authors:  Koichi Chida
Journal:  Radiol Phys Technol       Date:  2022-05-24

8.  Radiation Doses in Patient Eye Lenses during Interventional Neuroradiology Procedures.

Authors:  R M Sánchez; E Vañó; J M Fernández; S Rosati; L López-Ibor
Journal:  AJNR Am J Neuroradiol       Date:  2015-11-05       Impact factor: 3.825

9.  Patient radiation dose management in the follow-up of potential skin injuries in neuroradiology.

Authors:  E Vano; J M Fernandez; R M Sanchez; D Martinez; L Lopez Ibor; A Gil; C Serna-Candel
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-02       Impact factor: 3.825

10.  Local skin and eye lens equivalent doses in interventional neuroradiology.

Authors:  Michael Sandborg; Sandro Rossitti; Håkan Pettersson
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

View more