Literature DB >> 8188062

Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studies.

I Dielemans1, J R Vingerling, A Hofman, D E Grobbee, P T de Jong.   

Abstract

The reproducibility of intraocular pressure (IOP) measurement with the Goldmann applanation tonometer was investigated as part of a population-based epidemiological study. Sixty-two subjects were examined in a first measurement session. The IOP was measured three times consecutively in both eyes according to a fixed protocol. The mean standard deviation (SD) of these measurements was 0.8 mmHg. The mean intraobserver variation for the first measurement was 1.64 (SD 2.07) mmHg. For the median of the three measurements the intra-observer variation was 1.50 (SD 1.96) mmHg. The mean inter-observer values were 1.79 (SD 2.41) mmHg for the first measurement and 1.60 (SD 2.15) mmHg for the median measurement. The correlation coefficient between the median values of the three measurements of both observers was 0.81. No systematic differences were found between the two observers. Using the median value of three consecutive measurements reduced the inter-observer variation by 11% and the intra-observer variation by 9% compared with a single measurement.

Mesh:

Year:  1994        PMID: 8188062     DOI: 10.1007/bf00176782

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  21 in total

1.  Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer.

Authors:  H A Quigley; M E Langham
Journal:  Am J Ophthalmol       Date:  1975-08       Impact factor: 5.258

2.  [Applanation tonometry].

Authors:  H GOLDMANN; T SCHMIDT
Journal:  Ophthalmologica       Date:  1957-10       Impact factor: 3.250

3.  Repeated applanation tonometry.

Authors:  R A MOSES
Journal:  Ophthalmologica       Date:  1961       Impact factor: 3.250

4.  The Framingham Eye Study. I. Outline and major prevalence findings.

Authors:  H A Kahn; H M Leibowitz; J P Ganley; M M Kini; T Colton; R S Nickerson; T R Dawber
Journal:  Am J Epidemiol       Date:  1977-07       Impact factor: 4.897

5.  Racial variations in the prevalence of primary open-angle glaucoma. The Baltimore Eye Survey.

Authors:  J M Tielsch; A Sommer; J Katz; R M Royall; H A Quigley; J Javitt
Journal:  JAMA       Date:  1991-07-17       Impact factor: 56.272

6.  The accuracy of clinical applanation tonometry.

Authors:  W Thorburn
Journal:  Acta Ophthalmol (Copenh)       Date:  1978-02

7.  The two-period cross-over clinical trial.

Authors:  M Hills; P Armitage
Journal:  Br J Clin Pharmacol       Date:  1979-07       Impact factor: 4.335

8.  Intra-ocular pressure, glaucoma, and glaucoma suspects in a defined population.

Authors:  F C Hollows; P A Graham
Journal:  Br J Ophthalmol       Date:  1966-10       Impact factor: 4.638

9.  [On spontaneous decrease of pressure in applanation tonometry].

Authors:  E Bechrakis
Journal:  Ophthalmologica       Date:  1966       Impact factor: 3.250

10.  The prevalence of glaucoma.

Authors:  B Bengtsson
Journal:  Br J Ophthalmol       Date:  1981-01       Impact factor: 4.638

View more
  36 in total

1.  [Influence of corneal thickness on intraocular pressure measurements following Descemet's stripping automated endothelial keratoplasty (DSAEK)].

Authors:  M K J Klamann; A-K B Maier; J Gonnermann; N Torun; P C Ruokonen
Journal:  Ophthalmologe       Date:  2012-11       Impact factor: 1.059

2.  Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry.

Authors:  Domenico Schiano Lomoriello; Marco Lombardo; Laura Tranchina; Francesco Oddone; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-10-28       Impact factor: 3.117

3.  Pressure sensor based on flexible photonic crystal membrane.

Authors:  Torben Karrock; Martina Gerken
Journal:  Biomed Opt Express       Date:  2015-11-18       Impact factor: 3.732

4.  The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry.

Authors:  Teresio Avitabile; Antonio Longo; Daniela Rocca; Roberta Amato; Caterina Gagliano; Marine Castaing
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-08-29       Impact factor: 3.117

5.  Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.

Authors:  Senay Asik Nacaroglu; Emine Seker Un; Mehmet Giray Ersoz; Yelda Tasci
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

6.  Comparison of ICare and IOPen vs Goldmann applanation tonometry according to international standards 8612 in glaucoma patients.

Authors:  Milena Pahlitzsch; Jeanette Brünner; Johannes Gonnermann; Anna-Karina B Maier; Necip Torun; Eckart Bertelmann; Matthias Kj Klamann
Journal:  Int J Ophthalmol       Date:  2016-11-18       Impact factor: 1.779

7.  Improved prediction of fellow-eye response in one-eye trials using multiple intraocular pressure measurements.

Authors:  Yuka Wakabayashi; Tomomi Higashide; Kazuhisa Sugiyama
Journal:  Jpn J Ophthalmol       Date:  2011-07-05       Impact factor: 2.447

Review 8.  [Is there a connection between intraocular pressure and blood pressure? Results of the Gutenberg Health Study and review of the current study situation].

Authors:  R Höhn; A Mirshahi; I Zwiener; D Laubert-Reh; N Pfeiffer
Journal:  Ophthalmologe       Date:  2013-03       Impact factor: 1.059

Review 9.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

10.  Corticosteroids and open-angle glaucoma in the elderly: a population-based cohort study.

Authors:  Michael W Marcus; Rogier P H M Müskens; Wishal D Ramdas; Roger C W Wolfs; Paulus T V M De Jong; Johannes R Vingerling; Albert Hofman; Bruno H C Stricker; Nomdo M Jansonius
Journal:  Drugs Aging       Date:  2012-12       Impact factor: 3.923

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.