Literature DB >> 22752628

[Influence of corneal thickness on intraocular pressure measurements following Descemet's stripping automated endothelial keratoplasty (DSAEK)].

M K J Klamann1, A-K B Maier, J Gonnermann, N Torun, P C Ruokonen.   

Abstract

BACKGROUND: The aim of this study was to evaluate the effect of increased corneal thickness after Descemet's stripping automated endothelial keratoplasty (DSAEK) on intraocular pressure (IOP) measured by four different techniques.
METHODS: In this study 30 eyes from 30 patients with successful DSAEK treatment (group 1) and 30 eyes of 30 healthy subjects (group 2) were enrolled. The IOP was measured with iCare, IOPen, Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT) techniques. Central corneal thickness (CCT) was measured by ultrasonic pachymetry. These data were used for statistical analysis.
RESULTS: The mean IOP measured by GAT, DCT, iCare and IOPen was 13.2, 16.1, 12.5 and 14.2 mmHg in group 1 and 13.4, 14.4, 14.4 and 13.3 mmHg in group 2, respectively. Correlations between IOP and CCT were not statistically significant in either group.
CONCLUSION: The results of IOP measurements by the iCare, IOPen, GAT and DCT techniques seem to be unrelated to artificially thickened corneas after DSAEK. In spite of partially good correlation between the four techniques a direct exchange of the devices is not recommended on account of the wide dispersion of values.

Entities:  

Mesh:

Year:  2012        PMID: 22752628     DOI: 10.1007/s00347-012-2623-y

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  21 in total

1.  Sutureless, posterior lamellar keratoplasty: a case report of a modified technique.

Authors:  Gerrit R J Melles; Frank Lander; Carla Nieuwendaal
Journal:  Cornea       Date:  2002-04       Impact factor: 2.651

2.  Comparation of the new rebound tonometer IOPen and the Goldmann tonometer, and their relationship to corneal properties.

Authors:  J Moreno-Montañés; I Gosende; J Caire; M García-Granero
Journal:  Eye (Lond)       Date:  2010-10-01       Impact factor: 3.775

3.  The iCare rebound tonometer: comparisons with Goldmann tonometry, and influence of central corneal thickness.

Authors:  Ali Poostchi; Robert Mitchell; Simon Nicholas; Gordon Purdie; Anthony Wells
Journal:  Clin Exp Ophthalmol       Date:  2009-09       Impact factor: 4.207

4.  Descemet's stripping with endothelial keratoplasty: comparative outcomes with microkeratome-dissected and manually dissected donor tissue.

Authors:  Marianne O Price; Francis W Price
Journal:  Ophthalmology       Date:  2006-08-28       Impact factor: 12.079

5.  Deep lamellar endothelial keratoplasty visual acuity, astigmatism, and endothelial survival in a large prospective series.

Authors:  Mark A Terry; Paula J Ousley
Journal:  Ophthalmology       Date:  2005-09       Impact factor: 12.079

Review 6.  Sources of error with use of Goldmann-type tonometers.

Authors:  M M Whitacre; R Stein
Journal:  Surv Ophthalmol       Date:  1993 Jul-Aug       Impact factor: 6.048

7.  Small-incision deep lamellar endothelial keratoplasty (DLEK): six-month results in the first prospective clinical study.

Authors:  Mark A Terry; Paula J Ousley
Journal:  Cornea       Date:  2005-01       Impact factor: 2.651

8.  Descemet membrane endothelial keratoplasty (DMEK).

Authors:  Gerrit R J Melles; T San Ong; Bob Ververs; Jacqueline van der Wees
Journal:  Cornea       Date:  2006-09       Impact factor: 2.651

9.  Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis.

Authors:  Claude Kaufmann; Lucas M Bachmann; Michael A Thiel
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-09       Impact factor: 4.799

10.  Dynamic contour tonometry in comparison to intracameral IOP measurements.

Authors:  Andreas G Boehm; Anja Weber; Lutz E Pillunat; Rainer Koch; Eberhard Spoerl
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-03-03       Impact factor: 4.799

View more
  2 in total

1.  Intraocular pressure elevation and post-DMEK glaucoma following Descemet membrane endothelial keratoplasty.

Authors:  Anna-Karina B Maier; Tina Wolf; Enken Gundlach; Matthias K J Klamann; Johannes Gonnermann; Eckart Bertelmann; Antonia M Joussen; Necip Torun
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-08-07       Impact factor: 3.117

Review 2.  Challenges in the complex management of post-keratoplasty glaucoma.

Authors:  Lisa-Marie Anders; Zisis Gatzioufas; Matthias C Grieshaber
Journal:  Ther Adv Ophthalmol       Date:  2021-07-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.