Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetry.

Domenico Schiano Lomoriello1, Marco Lombardo, Laura Tranchina, Francesco Oddone, Sebastiano Serrao, Pietro Ducoli.   

Abstract

BACKGROUND: To examine the repeatability of intra-ocular pressure (IOP) and central corneal thickness (CCT) measurements provided by the Tono-Pachymeter NT530P (Nidek, Japan), and to assess agreement of the device with Goldmann applanation tonometry (GAT) and ultrasound pachymetry (UP).
METHODS: Sixty-two normal eyes of 62 subjects were included in the study. Three sessions of measurements, each consisting of three sets of measurements, were completed with each device. Repeatability was determined with the coefficient of variation (CoV) and the coefficient of repeatability (CoR) values. Agreement between devices was examined by Bland-Altman analysis and intraclass correlation coefficient (ICC) analyses.
RESULTS: The CoV and CoR for IOP values were 18.4% and 5.5 mmHg with the NT530P and 16.6% and 4.3 mmHg with the GAT respectively. On average, NT530P overestimated the IOP compared with GAT by 1.3 mmHg. The 95% limits of agreement between the methods ranged from -5.9 to +3.3 mmHg, and the ICC for average IOP measures between devices was 0.64 (P < 0.001). The CoV and CoR for CCT measurements were 5.5% and 59.8 μm with the NT530P and 5.5% and 60.5 μm with UP. NT530P CCT readings were on average 13 μm thinner than those obtained with UP. The 95% limits of agreement (LoA) ranged from -7.4 to +33.1 μm, and the ICC for average CCT measures between devices was 0.93 (P < 0.001).
CONCLUSION: The NT530P demonstrated high IOP and CCT measurement repeatability in the normal population studied. The device tended to slightly overestimate IOP compared to GAT. CCT values provided by NT530P were interchangeable with those of UP.

Entities:  

Mesh:

Year:  2010        PMID: 20981434     DOI: 10.1007/s00417-010-1550-3

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  31 in total

1.  Corneal thickness measurements with contact and noncontact specular microscopic and ultrasonic pachymetry.

Authors:  L Módis; A Langenbucher; B Seitz
Journal:  Am J Ophthalmol       Date:  2001-10       Impact factor: 5.258

2.  Clinical performance of the Reichert AT550: a new non-contact tonometer.

Authors:  J Jorge; J A Díaz-Rey; J M González-Méijome; J B Almeida; M A Parafita
Journal:  Ophthalmic Physiol Opt       Date:  2002-11       Impact factor: 3.117

3.  A comparison of four methods of tonometry: method agreement and interobserver variability.

Authors:  P-A Tonnu; T Ho; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

4.  Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry.

Authors:  Omür Ozlenen Uçakhan; Muhip Ozkan; Ayfer Kanpolat
Journal:  J Cataract Refract Surg       Date:  2006-06       Impact factor: 3.351

5.  Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography.

Authors:  Shiro Amano; Norihiko Honda; Yuki Amano; Satoru Yamagami; Takashi Miyai; Tomokazu Samejima; Miyuki Ogata; Kazunori Miyata
Journal:  Ophthalmology       Date:  2006-06       Impact factor: 12.079

6.  Clinical evaluation of the Canon TX-10 noncontact tonometer in healthy eyes.

Authors:  Carlos García-Resúa; María Jesús Giráldez Fernández; Eva Yebra-Pimentel; Silvia García-Montero
Journal:  Eur J Ophthalmol       Date:  2010 May-Jun       Impact factor: 2.597

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 8.  Sources of error with use of Goldmann-type tonometers.

Authors:  M M Whitacre; R Stein
Journal:  Surv Ophthalmol       Date:  1993 Jul-Aug       Impact factor: 6.048

9.  Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry.

Authors:  Ugo de Sanctis; Alessandro Missolungi; Bernardo Mutani; Lorenzo Richiardi; Federico M Grignolo
Journal:  Am J Ophthalmol       Date:  2007-09-17       Impact factor: 5.258

10.  Effect of corneal hydration on ultrasound velocity and backscatter.

Authors:  Ronald H Silverman; Monica S Patel; Omer Gal; Aman Sarup; Avnish Deobhakta; Haitham Dababneh; Dan Z Reinstein; Ernest J Feleppa; D Jackson Coleman
Journal:  Ultrasound Med Biol       Date:  2009-02-05       Impact factor: 2.998

View more
  6 in total

1.  Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry.

Authors:  Jan Luebke; L Bryniok; M Neuburger; J F Jordan; D Boehringer; T Reinhard; T Wecker; A Anton
Journal:  Int Ophthalmol       Date:  2019-04-09       Impact factor: 2.031

2.  Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology.

Authors:  Erhan Ozyol; Pelin Özyol
Journal:  Indian J Ophthalmol       Date:  2017-06       Impact factor: 1.848

3.  Validity of Tono-pachymetry for Measuring Corrected Intraocular Pressure in Non-surgical and Post-photorefractive Keratectomy Eyes.

Authors:  In Kyun Hahn; Jae Yong Kim; Myoung Joon Kim; Hungwon Tchah; Chan Hee Moon
Journal:  Korean J Ophthalmol       Date:  2017-02-02

4.  Intraocular Pressure Based on Dynamic Bidirectional Applanation and Air-puff Tonometry: A Comparative Study.

Authors:  Ayse E Bahadir Kilavuzoglu; Cemile B Cosar; Ali Rc Celebi; Ugur E Al Parmak
Journal:  J Curr Glaucoma Pract       Date:  2019 May-Aug

5.  Central Corneal Thickness Measurements with Different Imaging Devices: Ultrasound Pachymetry, Noncontact Specular Microscopy, and Tono-Pachymetry.

Authors:  Ali Ceylan; Irem Onal; Burak Mergen; Yusuf Yildirim
Journal:  Beyoglu Eye J       Date:  2022-02-18

6.  Comparison of the corrected intraocular pressure by tonopachy with that of Goldmann applanation tonometry in normal and glaucomatous patients.

Authors:  Girish Velis; Srinivasan Kavitha; Nazlee Zebardast; Sabyasachi Sengupta; Rengaraj Venkatesh
Journal:  Indian J Ophthalmol       Date:  2020-04       Impact factor: 1.848

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.