Comparative intraocular pressure measurements with the pneumatonograph and Goldmann tonometer.

H A Quigley, M E Langham.   

Abstract

Comparative intraocular pressure measurements made with the pneumatonograph and the Goldmann tonometer showed close agreement with a statistically higher mean pressure when using the pneumatonograph. Significant changes in mean pressure differences between the two instruments were seen upon changing the pneumatonograph calibration and with change in the order of testing (which instrument was used initially). However, transient biologic changes in an individual eye producing minute-to-minute fluctuations in intraocular pressure may be equal to or larger than differences in measurement between instruments.

Mesh:

Year:  1975        PMID: 1155566     DOI: 10.1016/0002-9394(75)90144-0

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  11 in total

1.  [Intraocular pressure measurements on soft contact lenses (author's transl)].

Authors:  G K Krieglstein; W K Waller; H Reimers; M E Langham
Journal:  Albrecht Von Graefes Arch Klin Exp Ophthalmol       Date:  1976-05-26

2.  Measurement of intraocular pressure after epikeratophakia.

Authors:  M M Wright; A L Grajewski
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

3.  Rapid pneumatic and Mackey-Marg applanation tonometry to evaluate the postural effect on intraocular pressure.

Authors:  M R Jain; V J Marmion
Journal:  Br J Ophthalmol       Date:  1976-10       Impact factor: 4.638

4.  Deviations between transpalpebral tonometry using TGDc-01 and Goldmann applanation tonometry depending on the IOP level.

Authors:  Annette Troost; Kathrin Specht; Frank Krummenauer; Sung Hyun Yun; Oliver Schwenn
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-15       Impact factor: 3.117

5.  Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studies.

Authors:  I Dielemans; J R Vingerling; A Hofman; D E Grobbee; P T de Jong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-03       Impact factor: 3.117

6.  Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

Authors:  M J Ménage; P L Kaufman; M A Croft; S P Landay
Journal:  Br J Ophthalmol       Date:  1994-09       Impact factor: 4.638

7.  Circulatory changes in the eye associated with retinal detachment and its repair.

Authors:  J G Dobbie
Journal:  Trans Am Ophthalmol Soc       Date:  1980

8.  A clinical evaluation of the applanation pneumatonograph.

Authors:  M R Jain; V J Marmion
Journal:  Br J Ophthalmol       Date:  1976-02       Impact factor: 4.638

9.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

10.  Postural studies in pulsatile ocular blood flow: I. Ocular hypertension and normotension.

Authors:  D R Trew; S E Smith
Journal:  Br J Ophthalmol       Date:  1991-02       Impact factor: 4.638

View more