Effectiveness of antiscatter grids in digital radiography. A phantom study.

C C Shaw1, T Wang, D Gur.   

Abstract

INTRODUCTION: With ever-increasing interest in bedside radiography using digital imaging techniques, one question often asked is whether and which antiscatter grid should be used to reduce the effects of scattered radiation. In this article, the authors quantitatively analyze and compare images obtained with a flexible circular hole (FCH) grid, a conventional 6:1 focused grid, or without a grid.
METHODS: Scatter-to-primary ratios (SPRs), contrast signals, and contrast-to-noise ratios (CNRs) were measured for fixed patient exposure and were compared at various locations in the images of an anthropomorphic chest phantom.
RESULTS: Although both grids resulted in greater contrast signals, a significant improvement of the CNR was achieved only in the upper and middle mediastinum regions when the conventional grid was used. With the FCH grid, the CNR is degraded at most locations in the chest image. DISCUSSION: Our results indicate that at fixed exposure level, the use of either grid yields only marginal improvement, at best, in bedside digital chest radiography.

Entities:  

Mesh:

Year:  1994        PMID: 8088973     DOI: 10.1097/00004424-199406000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

3.  A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform.

Authors:  Hui Tang; Dan Tong; Xu Dong Bao; Jean-Louis Dillenseger
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

4.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

5.  An alternate line erasure and readout (ALER) method for implementing slot-scan imaging technique with a flat-panel detector--initial experiences.

Authors:  Xinming Liu; Chris C Shaw; Mustafa C Altunbas; Tianpeng Wang
Journal:  IEEE Trans Med Imaging       Date:  2006-04       Impact factor: 10.048

6.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

7.  A static multi-slit collimator system for scatter reduction in cone-beam CT.

Authors:  Jina Chang; Siyong Kim; Doh-Yun Jang; Tae-Suk Suh
Journal:  J Appl Clin Med Phys       Date:  2010-10-07       Impact factor: 2.102

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.