A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular component.

L M Kwong1, D O O'Connor, R C Sedlacek, R J Krushell, W J Maloney, W H Harris.   

Abstract

This investigation quantifies in vitro the effect of component fit, as well as the effect of adjuvant screw fixation, on the initial stability of cementless hemispherical titanium acetabular total hip arthroplasty components and assesses apposition of the acetabular components to bone. Six, fresh human hemipelvi (3 matched pairs) were harvested at autopsy. Titanium alloy acetabular components with a porous surface of commercially pure titanium fiber mesh (Harris Galante Porous acetabular components, Zimmer, Warsaw, IN) were used for implantation. Initially, each acetabulum was underreamed to achieve a 2 mm press-fit with the acetabular component. Pressure-sensitive film had been placed along the dome and medial wall at the bone-implant interface to assess the completeness of seating. After the implant was impacted into the acetabular cavity, relative motion between the implant and bone was measured during simulated single leg stance. Adjuvant fixation of the implant was then obtained with the insertion of four 6.5 mm cancellous screws. High-contrast roentgenograms of the specimens in multiple views were obtained after initial cup insertion and again after screw insertion. The stability of each implant under load was measured with four, three, two, one, and no screws in place. Further reaming of the bone was done to create a 1 mm press-fit. The sequence was then repeated. Further reaming was done to create an exact-fit and the sequence was repeated again. Under these conditions, 1 mm press-fit with or without screws provided the optimum combination of fit stability.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8014647     DOI: 10.1016/0883-5403(94)90065-5

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  17 in total

1.  Radiographic evaluation of the Duraloc cup after 4 years.

Authors:  B Stoeckl; E Brabec; S Wanner; M Krismer; R Biedermann
Journal:  Int Orthop       Date:  2004-10-14       Impact factor: 3.075

2.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

3.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

4.  Effect of screw fixation on acetabular component alignment change in total hip arthroplasty.

Authors:  Takaaki Fujishiro; Shinya Hayashi; Noriyuki Kanzaki; Shingo Hashimoto; Nao Shibanuma; Masahiro Kurosaka
Journal:  Int Orthop       Date:  2014-01-11       Impact factor: 3.075

5.  Validation of FE micromotions and strains around a press-fit cup: introducing a new micromotion measuring technique.

Authors:  S G Clarke; A T M Phillips; A M J Bull
Journal:  Ann Biomed Eng       Date:  2012-02-16       Impact factor: 3.934

6.  Protrusio After Medial Acetabular Wall Breach in Total Hip Arthroplasty.

Authors:  Christopher T Martin; Anneliese D Heiner; Thomas E Baer; Andrew J Pugely; Nicolas O Noiseux
Journal:  Iowa Orthop J       Date:  2015

7.  Cup press fit in uncemented THA depends on sex, acetabular shape, and surgical technique.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

8.  Cementless jumbo cups for revision of failed Furlong prosthesis. A case series.

Authors:  Ahmed Salem Eid; Ahmed Kotb; Waleed Elshabrawy
Journal:  J Clin Orthop Trauma       Date:  2018-08-11

9.  Migration pattern of cementless press fit cups in the presence of stabilizing screws in total hip arthroplasty.

Authors:  C Zilkens; S Djalali; B Bittersohl; T Kälicke; C N Kraft; R Krauspe; Marcus Jäger
Journal:  Eur J Med Res       Date:  2011-03-28       Impact factor: 2.175

10.  Primary stability of two uncementedacetabular components of different geometry: hemispherical or peripherallyenhanced?

Authors:  G Antoniades; E J Smith; A H Deakin; S C Wearing; M Sarungi
Journal:  Bone Joint Res       Date:  2013-12-10       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.