Literature DB >> 15490162

Radiographic evaluation of the Duraloc cup after 4 years.

B Stoeckl1, E Brabec, S Wanner, M Krismer, R Biedermann.   

Abstract

We implanted 71 metal-backed, porous-coated, hemispheric, press-fit Duraloc-100 cups in 68 consecutive patients. In 61 patients, the femoral stem was a cementless Spotorno and in ten a cemented Lubinus SP II. A 28-mm Biolox ceramic head was used with both stems. After an average follow-up of 4 (3.7-5.9) years, we examined 67 hips. Radiolucencies were described in three zones according to DeLee and Charnley, and migration was measured on serial radiographs using the computer-assisted EBRA method. Total migration of more than 1 mm within the first 2 years occurred in 22/62 cups. Nine cups showed more than 1.5 mm total migration within the first 2 years and more than 2 mm within the whole period. The presence of post-operative radiolucencies correlated significantly with a total migration value of more than 2 mm within the first 2 years (p=0.02). Post-operative radiolucencies in zone 1 correlated with a total migration value of more than 2 mm within the first 2 years (p=0.027) and more than 2.5 mm within the whole period (p=0.051). These correlation values might reflect the quality of operative technique, particularly reaming, and implant selection.

Entities:  

Mesh:

Year:  2004        PMID: 15490162      PMCID: PMC3456950          DOI: 10.1007/s00264-004-0600-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  19 in total

1.  Migration of the Duraloc cup at two years.

Authors:  B Stöckl; M Sandow; M Krismer; R Biedermann; C Wimmer; B Frischhut
Journal:  J Bone Joint Surg Br       Date:  1999-01

2.  Load transfer and fixation mode of press-fit acetabular sockets.

Authors:  K-H Widmer; B Zurfluh; E W Morscher
Journal:  J Arthroplasty       Date:  2002-10       Impact factor: 4.757

3.  Cementless acetabular components.

Authors:  C A Engh; W L Griffin; C L Marx
Journal:  J Bone Joint Surg Br       Date:  1990-01

Review 4.  Fixation and loosening of hip prostheses. A review.

Authors:  B Mjöberg
Journal:  Acta Orthop Scand       Date:  1991-10

5.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

6.  The acetabular component in total hip arthroplasty. Evaluation of different fixation principles.

Authors:  J Thanner
Journal:  Acta Orthop Scand Suppl       Date:  1999-08

7.  [Long-term results of 2 uncemented acetabular cup components in total hip prosthesis].

Authors:  D Schmitt; O Bigard; F Bresler; D Molé; P Bernard
Journal:  Int Orthop       Date:  1993-12       Impact factor: 3.075

8.  Histological and radiographic assessment of well functioning porous-coated acetabular components. A human postmortem retrieval study.

Authors:  C A Engh; K F Zettl-Schaffer; Y Kukita; D Sweet; M Jasty; C Bragdon
Journal:  J Bone Joint Surg Am       Date:  1993-06       Impact factor: 5.284

9.  Evaluation of initial surface apposition in porous-coated acetabular components.

Authors:  J T Schwartz; C A Engh; M R Forte; Y Kukita; S K Grandia
Journal:  Clin Orthop Relat Res       Date:  1993-08       Impact factor: 4.176

10.  Principles of acetabular fixation in THR with special reference to the "press-fit cup".

Authors:  E Morscher
Journal:  Acta Orthop Belg       Date:  1993       Impact factor: 0.500

View more
  6 in total

1.  Migration of the Duraloc cup after 5 years.

Authors:  Christoph Stihsen; Christof Pabinger; Roman Radl; Peter Rehak; Reinhard Windhager
Journal:  Int Orthop       Date:  2007-07-03       Impact factor: 3.075

2.  Aseptic stem loosening in primary THA: migration analysis of cemented and cementless fixation.

Authors:  Artur Kroell; Paul Beaulé; Martin Krismer; Hannes Behensky; Bernd Stoeckl; Rainer Biedermann
Journal:  Int Orthop       Date:  2008-12-06       Impact factor: 3.075

3.  Migration characteristics and early clinical results of a novel-finned press-fit acetabular cup.

Authors:  Martin Kaipel; Anton Prenner; Sebastian Bachl; Sebastian Farr; Günter Sinz
Journal:  Wien Klin Wochenschr       Date:  2014-01-18       Impact factor: 1.704

4.  The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.

Authors:  Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner
Journal:  BMC Musculoskelet Disord       Date:  2021-01-23       Impact factor: 2.362

5.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

6.  Two-year radiologic assessment of the Pinnacle cup-a migration analysis with EBRA.

Authors:  Dietmar Dammerer; Alexander Ruzicka; Philipp Blum; David Putzer; Maximilian Liebsch; Julian Lair; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-30       Impact factor: 3.067

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.