Literature DB >> 8012871

The effect of increasing gap width on localized densitometric changes within tibial ostectomies in a canine model.

M D Markel1, J J Bogdanske.   

Abstract

Dual-energy X-ray absorptiometry (DXA) was used to quantitate the localized densitometric changes that occur early (0-16 weeks) in a tibial ostectomy model of three different gap widths in 15 dogs. Dogs were divided into three equal groups. A 5-mm (group 1), 15-mm (group 2), or 25-mm (group 3) unilateral tibial ostectomy was performed and stabilized with a unilateral external skeletal fixator in each dog. DXA of the gap tissue was performed at 0, 14, 30, 60, 90, and 120 days after surgery. Regions of interest (ROIs) included the entire gap (groups 1, 2, 3) and ROIs within the gap a defined distance from the proximal or distal cortical bone ends: 0-2.5 mm (groups 1, 2, 3); 2.5-5.0 mm (groups 2, 3), 5.0-7.5 mm (groups 2, 3), 7.5-10.0 mm (group 3), and 10.0-12.5 mm (group 3). Bone mineral density (BMD) significantly changed over time in all three groups (P < 0.0001). The BMD of the 5-mm gap increased over the 4-month study period and reached normal middiaphysial tibial BMD by 90 days after surgery. The BMD of the 15-mm gap also increased after surgery but reached a plateau at a BMD of approximately 0.45 g/cm2 (48% of middiaphyseal BMD) at 60 days after surgery. The BMD of the 25-mm gap increased to a small extent during the first 30 days after surgery and then gradually decreased during the study period. Overall, the 5-mm gap had the highest BMD, followed by the 15-mm gap and the 25-mm gap (P < 0.0001).

Entities:  

Mesh:

Year:  1994        PMID: 8012871     DOI: 10.1007/bf00296067

Source DB:  PubMed          Journal:  Calcif Tissue Int        ISSN: 0171-967X            Impact factor:   4.333


  20 in total

1.  A method of using sections of bone prepared for microangiography for subsequent histologic study.

Authors:  P J KELLY; L F PETERSON; J M JANES
Journal:  Proc Staff Meet Mayo Clin       Date:  1959-05-27

2.  In vitro comparability of dual energy X-ray absorptiometry (DEXA) bone densitometers.

Authors:  M L Rencken; R Murano; B L Drinkwater; C H Chesnut
Journal:  Calcif Tissue Int       Date:  1991-04       Impact factor: 4.333

3.  Calibration and standardization of bone mineral densitometers.

Authors:  T L Kelly; D M Slovik; R M Neer
Journal:  J Bone Miner Res       Date:  1989-10       Impact factor: 6.741

4.  The determination of bone fracture properties by dual-energy X-ray absorptiometry and single-photon absorptiometry: a comparative study.

Authors:  M D Markel; M A Wikenheiser; R L Morin; D G Lewallen; E Y Chao
Journal:  Calcif Tissue Int       Date:  1991-06       Impact factor: 4.333

5.  Calibration of dual-energy x-ray absorptiometry for bone density.

Authors:  R B Mazess; J A Trempe; J P Bisek; J A Hanson; D Hans
Journal:  J Bone Miner Res       Date:  1991-08       Impact factor: 6.741

6.  Precision and stability of dual-energy X-ray absorptiometry measurements.

Authors:  J Johnson; B Dawson-Hughes
Journal:  Calcif Tissue Int       Date:  1991-09       Impact factor: 4.333

7.  Sequential and precise in vivo measurement of bone mineral density in rats using dual-energy x-ray absorptiometry.

Authors:  P Ammann; R Rizzoli; D Slosman; J P Bonjour
Journal:  J Bone Miner Res       Date:  1992-03       Impact factor: 6.741

8.  Microangiography in bone healing. II. Displaced closed fractures.

Authors:  F W Rhinelander; R S Phillips; W M Steel; J C Beer
Journal:  J Bone Joint Surg Am       Date:  1968-06       Impact factor: 5.284

9.  Comparison of the effects of compression plates and external fixators on early bone-healing.

Authors:  D G Lewallen; E Y Chao; R A Kasman; P J Kelly
Journal:  J Bone Joint Surg Am       Date:  1984-09       Impact factor: 5.284

Review 10.  The biology of fracture healing. An overview for clinicians. Part I.

Authors:  H M Frost
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

View more
  3 in total

1.  A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws.

Authors:  Manoj Goyal; Aakarsh Jhamb; Sonia Chawla; Karan Marya; J S Dua; Suman Yadav
Journal:  J Maxillofac Oral Surg       Date:  2012-03-27

2.  The fracture gap size influences the local vascularization and tissue differentiation in callus healing.

Authors:  Lutz Claes; Kerstin Eckert-Hübner; Peter Augat
Journal:  Langenbecks Arch Surg       Date:  2003-09-09       Impact factor: 3.445

3.  [Mechanobiology of fracture healing part 1 : Principles].

Authors:  L Claes
Journal:  Unfallchirurg       Date:  2017-01       Impact factor: 1.000

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.