Abstract

We used two mechanically dissimilar devices, compression bone-plates and unilateral-frame external fixators, in a standard canine osteotomy model; both methods were highly successful in achieving mature bone union. Bone union was studied by histological, physiological, and biomechanical means. At 120 days after injury, union was biomechanically less mature on the external fixator side. These tibiae had less intracortical new-bone formation (p less than 0.01), more bone resorption (p less than 0.045), and more bone porosity (p less than 0.04) when compared with paired tibiae that had been treated with compression plates. This higher level of bone turnover on the external fixator side was accompanied by an increase in blood flow (measured by clearance of 85Sr) (p less than 0.04). At the osteotomy site, pre-experimental or unlabeled bone and porosity were greater on the external fixator side and endosteal new-bone formation was greater on the plated side. Since the in vitro stiffness of the external fixator was less in all modes tested (compression, distraction, torsion, and anteroposterior bending) except lateral bending, it may be that the rigidity of the fixation is an important factor in early bone-remodeling of a healing osteotomy.

Entities:  

Mesh:

Year:  1984        PMID: 6480637

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  8 in total

Review 1.  Optimal mechanical environment of the healing bone fracture/osteotomy.

Authors:  Blaž Mavčič; Vane Antolič
Journal:  Int Orthop       Date:  2012-02-03       Impact factor: 3.075

2.  The determination of bone fracture properties by dual-energy X-ray absorptiometry and single-photon absorptiometry: a comparative study.

Authors:  M D Markel; M A Wikenheiser; R L Morin; D G Lewallen; E Y Chao
Journal:  Calcif Tissue Int       Date:  1991-06       Impact factor: 4.333

3.  A comparison of two headless compression screws for operative treatment of scaphoid fractures.

Authors:  Ruby Grewal; Joseph Assini; David Sauder; Louis Ferreira; Jim Johnson; Kenneth Faber
Journal:  J Orthop Surg Res       Date:  2011-06-07       Impact factor: 2.359

4.  Comparison of the mechanical performance of three types of unilateral, dynamizable external fixators. An experimental study.

Authors:  R A Jaskulka; E Egkher; B Wielke
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

5.  Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.

Authors:  Zi-Li Wang; Rong-Zhen He; Bin Tu; Xu Cao; Jin-Shen He; Han-Song Xia; Chi Liang; Min Zou; Song Wu; Zhen-Jun Wu; Kun Xiong
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

6.  The effect of increasing gap width on localized densitometric changes within tibial ostectomies in a canine model.

Authors:  M D Markel; J J Bogdanske
Journal:  Calcif Tissue Int       Date:  1994-02       Impact factor: 4.333

7.  Treatment of scaphoid waist fractures with the HCS screw.

Authors:  Sebastian V Gehrmann; Jan-Peter Grassmann; Michael Wild; Pascal Jungbluth; Robert A Kaufmann; Joachim Windolf; Mohssen Hakimi
Journal:  GMS Interdiscip Plast Reconstr Surg DGPW       Date:  2014-11-24

8.  The Accuracy of Pain Measurement in Diagnosis of Scaphoid Bone Fractures in Patients with Magnetic Resonance Imaging: Report of 175 Cases.

Authors:  Mohammad Davood Sharifi; Hamid Zamani Moghaddam; Hosein Zakeri; Mohsen Ebrahimi; Hesamoddin Saeedian; Amir Masoud Hashemian
Journal:  Med Arch       Date:  2015-06-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.