The Tono-Pen. A manometric and clinical study.

W A Boothe1, D A Lee, W C Panek, T H Pettit.   

Abstract

A new miniaturized, digital, electronic tonometer, the Tono-Pen (Intermedics, Pasadena, Calif), was evaluated for accuracy and reproducibility of results in the laboratory using enucleated human eyes with an indwelling pressure transducer (manometric study) and clinically using 100 eyes in 50 patients with normal corneas. Reproducibility was good in both the manometric study (SD = 1.09) and in the clinical study (SD = 1.21). Reproducibility of results was similar to that of the MacKay-Marg tonometer and the pneumotonometer in the manometric study, but less than that of the Goldmann applanation tonometer and the pneumotonometer in the clinical study. In the manometric study, the Tono-Pen had less mean error at high pressure ranges than either the MacKay-Marg tonometer or the pneumotonometer. In the clinical study, no statistically significant difference was found between the Tono-Pen and the applanation tonometer at pressures of 10 to 35 mm Hg (the extent of the data spread). In addition to being reliable and accurate, this miniaturized tonometer is portable and easy to use.

Entities:  

Mesh:

Year:  1988        PMID: 3415545     DOI: 10.1001/archopht.1988.01060140374035

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  8 in total

1.  Measurement of intraocular pressure after epikeratophakia.

Authors:  M M Wright; A L Grajewski
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

2.  Ocular blood flow measurements in healthy human myopic eyes.

Authors:  Alexandra Benavente-Pérez; Sarah L Hosking; Nicola S Logan; David C Broadway
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-05-26       Impact factor: 3.117

3.  Evaluation of intraocular pressure according to corneal thickness before and after excimer laser corneal ablation for myopia.

Authors:  Shirin Hamed-Azzam; Daniel Briscoe; Oren Tomkins; Raneen Shehedeh-Mashor; Hanna Garzozi
Journal:  Int Ophthalmol       Date:  2012-12-29       Impact factor: 2.031

4.  Prevention of intraocular pressure rise following intravitreal injection.

Authors:  N Morlet; S H Young
Journal:  Br J Ophthalmol       Date:  1993-09       Impact factor: 4.638

5.  Clinical comparison of the ProTon and Tono-Pen tonometers with the Goldmann applanation tonometer.

Authors:  A Midelfart; A Wigers
Journal:  Br J Ophthalmol       Date:  1994-12       Impact factor: 4.638

6.  Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

Authors:  M J Ménage; P L Kaufman; M A Croft; S P Landay
Journal:  Br J Ophthalmol       Date:  1994-09       Impact factor: 4.638

7.  Change in intraocular pressure during scleral depression.

Authors:  Richard Trevino; Brandi Stewart
Journal:  J Optom       Date:  2014-10-31

8.  Detecting IOP Fluctuations in Glaucoma Patients.

Authors:  Brenda Nuyen; Kaweh Mansouri
Journal:  Open Ophthalmol J       Date:  2016-02-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.