Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors.

A D Maidment1, M J Yaffe.   

Abstract

The effect of optical coupling efficiency on the spatial-frequency-dependent propagation of signal and noise is considered for x-ray image detectors for digital mammography in which a phosphor screen is optically coupled to a charge-coupled device (CCD) image array. For experimental purposes, optical coupling between a Gd2O2S:Tb phosphor screen and a CCD image array was provided by relay lenses. Neutral density filters were inserted between the lenses to vary the optical coupling efficiency without altering the inherent spatial resolution. The total coupling efficiency, defined as the number of electrons (e-) recorded in the CCD per x-ray interaction in the phosphor, was calculated in each case. The modulation transfer function, and the contributions to the total noise power spectrum (NPS) of x-ray quantum noise, secondary quantum noise, and inherent detector noise were measured as a function of coupling efficiency. These data were used to calculate the spatial-frequency-dependent detective quantum efficiency [DQE(f)]. The NPS due to x-ray quantum noise had a significant spatial-frequency dependence for coupling efficiencies of more than 9 e- per x-ray interaction, but little spatial-frequency dependence for coupling efficiencies of less than 2 e- per x-ray interaction. These results indicate that to preserve high spatial-frequency values of DQE(f), and to ensure that images are x-ray quantum-noise limited at high spatial frequencies, a coupling efficiency on the order of 10 e- per x-ray interaction is required.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 7935207     DOI: 10.1118/1.597331

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Steven K Onishi
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

2.  High-DQE EPIDs based on thick, segmented BGO and CsI:Tl scintillators: performance evaluation at extremely low dose.

Authors:  Yi Wang; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Louis Perna
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

3.  ACR-AAPM-SIIM practice guideline for determinants of image quality in digital mammography.

Authors:  Kalpana M Kanal; Elizabeth Krupinski; Eric A Berns; William R Geiser; Andrew Karellas; Martha B Mainiero; Melissa C Martin; Samir B Patel; Daniel L Rubin; Jon D Shepard; Eliot L Siegel; Judith A Wolfman; Tariq A Mian; Mary C Mahoney
Journal:  J Digit Imaging       Date:  2013-02       Impact factor: 4.056

4.  Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging.

Authors:  Yi Wang; Youcef El-Mohri; Larry E Antonuk; Qihua Zhao
Journal:  Phys Med Biol       Date:  2010-06-04       Impact factor: 3.609

5.  Optimization of the performance of segmented scintillators for radiotherapy imaging through novel binning techniques.

Authors:  Youcef El-Mohri; Larry E Antonuk; Richard B Choroszucha; Qihua Zhao; Hao Jiang; Langechuan Liu
Journal:  Phys Med Biol       Date:  2014-02-03       Impact factor: 3.609

6.  Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging.

Authors:  Hao Jiang; Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Tapan Gupta
Journal:  Phys Med Biol       Date:  2013-01-14       Impact factor: 3.609

7.  Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors.

Authors:  Youcef El-Mohri; Larry E Antonuk; Martin Koniczek; Qihua Zhao; Yixin Li; Robert A Street; Jeng-Ping Lu
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

8.  Scanning translucent glass-ceramic x-ray storage phosphors.

Authors:  A R Lubinsky; J A Johnson; S Schweizer; J K R Weber; R M Nishikawa; P Domenicali; S D Fantone
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-03-22

9.  Countering beam divergence effects with focused segmented scintillators for high DQE megavoltage active matrix imagers.

Authors:  Langechuan Liu; Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Hao Jiang
Journal:  Phys Med Biol       Date:  2012-08-01       Impact factor: 3.609

Review 10.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.