Literature DB >> 23318606

Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging.

Hao Jiang1, Qihua Zhao, Larry E Antonuk, Youcef El-Mohri, Tapan Gupta.   

Abstract

Active matrix flat-panel imagers (AMFPIs) offer many advantages and have become ubiquitous across a wide variety of medical x-ray imaging applications. However, for mammography, the imaging performance of conventional AMFPIs incorporating CsI:Tl scintillators or a-Se photoconductors is limited by their relatively modest signal-to-noise ratio (SNR), particularly at low x-ray exposures or high spatial resolution. One strategy for overcoming this limitation involves the use of a high gain photoconductor such as mercuric iodide (HgI(2)) which has the potential to improve the SNR by virtue of its low effective work function (W(EFF)). In this study, the performance of direct-detection AMFPI prototypes employing relatively thin layers of polycrystalline HgI(2) operated under mammographic irradiation conditions over a range of 0.5 to 16.0 mR is presented. High x-ray sensitivity (corresponding to W(EFF) values of ∼19 eV), low dark current (<0.1 pA mm(-2)) and good spatial resolution, largely limited by the size of the pixel pitch, were observed. For one prototype, a detective quantum efficiency of ∼70% was observed at an x-ray exposure of ∼0.5 mR at 26 kVp.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23318606      PMCID: PMC3620658          DOI: 10.1088/0031-9155/58/3/703

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.

Authors:  L E Antonuk; K W Jee; Y El-Mohri; M Maolinbay; S Nassif; X Rong; Q Zhao; J H Siewerdsen; R A Street; K S Shah
Journal:  Med Phys       Date:  2000-02       Impact factor: 4.071

2.  The x-ray sensitivity of amorphous selenium for mammography.

Authors:  Mary F Stone; Wei Zhao; Barbara V Jacak; Paul O'Connor; Bo Yu; Pavel Rehak
Journal:  Med Phys       Date:  2002-03       Impact factor: 4.071

3.  Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.

Authors:  Wei Zhao; W G Ji; Anne Debrie; J A Rowlands
Journal:  Med Phys       Date:  2003-02       Impact factor: 4.071

4.  System performance of a prototype flat-panel imager operated under mammographic conditions.

Authors:  Kyung-Wook Jee; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

5.  Contrast-enhanced dedicated breast CT: initial clinical experience.

Authors:  Nicolas D Prionas; Karen K Lindfors; Shonket Ray; Shih-Ying Huang; Laurel A Beckett; Wayne L Monsky; John M Boone
Journal:  Radiology       Date:  2010-09       Impact factor: 11.105

6.  Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.

Authors:  Zhong Su; Larry E Antonuk; Youcef El-Mohri; Larry Hu; Hong Du; Amit Sawant; Yixin Li; Yi Wang; Jin Yamamoto; Qihua Zhao
Journal:  Phys Med Biol       Date:  2005-06-01       Impact factor: 3.609

7.  Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Yi Wang; Yixin Li; Hong Du; Amit Sawant
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

8.  Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2.

Authors:  Hong Du; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Zhong Su; Jin Yamamoto; Yi Wang
Journal:  Phys Med Biol       Date:  2008-02-14       Impact factor: 3.609

9.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

10.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.

Authors:  I A Cunningham; M S Westmore; A Fenster
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

View more
  6 in total

1.  Evaluation of a hybrid direct-indirect active matrix flat-panel imager using Monte Carlo simulation.

Authors:  Scott Dow; Adrian Howansky; Anthony R Lubinsky; Wei Zhao
Journal:  J Med Imaging (Bellingham)       Date:  2020-05-12

2.  Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors.

Authors:  Martin Koniczek; Larry E Antonuk; Youcef El-Mohri; Albert K Liang; Qihua Zhao
Journal:  Med Phys       Date:  2017-05-22       Impact factor: 4.071

3.  Investigation of the electronic structural and optical properties of CH3NH3HgI3 crystal.

Authors:  Ming Yao; Gang Xu; Mingtao Zhang; Binbin Zhang; Jinmeng Zhu; Chunhai Wang
Journal:  J Mol Model       Date:  2022-08-13       Impact factor: 2.172

4.  Characterization of polycrystalline lead oxide for application in direct conversion X-ray detectors.

Authors:  O Semeniuk; O Grynko; G Decrescenzo; G Juska; K Wang; A Reznik
Journal:  Sci Rep       Date:  2017-08-17       Impact factor: 4.379

5.  Simulation and design of folded perovskite x-ray detectors.

Authors:  Henning Mescher; Elias Hamann; Uli Lemmer
Journal:  Sci Rep       Date:  2019-03-26       Impact factor: 4.379

6.  Direct Thermal Growth of Large Scale Cl-doped CdTe Film for Low Voltage High Resolution X-ray Image Sensor.

Authors:  Silah Lee; Jin Sung Kim; Kyeong Rok Ko; Gun Hwan Lee; Dong Jin Lee; Dong Wook Kim; Jin Eui Kim; Ho Kyung Kim; Dong Woon Kim; Seongil Im
Journal:  Sci Rep       Date:  2018-10-04       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.