Scanning translucent glass-ceramic x-ray storage phosphors.

A R Lubinsky1, J A Johnson, S Schweizer, J K R Weber, R M Nishikawa, P Domenicali, S D Fantone.   

Abstract

A simple benchtop apparatus has been built, to measure the x-ray imaging properties of fluorozirconate-based glass-ceramic x-ray storage phosphor materials. The MTF degradation due to stimulating light spreading in the plate is lower in comparison to optically turbid screens resulting in higher image MTF. In addition, the degree of transparency, or the amount of light scattering at the wavelength of the stimulating (laser) light is adjustable by means of the glass preparation process. The amount of stimulating exposure required for plate readout is generally higher than in previous systems, but well within the range of commercially available laser systems, for practical readout times. The effects of flare or unwanted readout due to back-reflection from the imaging plate is also less than in previous systems.A novel telecentric scanning system has been developed that is able to rapidly read out the latent image stored in the translucent imaging plates. This system features a reflective primary scan mirror to achieve telecentricity, optical correction for scan line bow, and the design should enable the construction of a relatively inexpensive scanner system for the translucent x-ray storage plates.

Entities:  

Year:  2010        PMID: 23264857      PMCID: PMC3526193          DOI: 10.1117/12.843346

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  3 in total

Review 1.  The physics of computed radiography.

Authors:  J A Rowlands
Journal:  Phys Med Biol       Date:  2002-12-07       Impact factor: 3.609

2.  Detective quantum efficiency of imaging systems with amplifying and scattering mechanisms.

Authors:  M Rabbani; R Shaw; R Van Metter
Journal:  J Opt Soc Am A       Date:  1987-05       Impact factor: 2.129

3.  Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors.

Authors:  A D Maidment; M J Yaffe
Journal:  Med Phys       Date:  1994-06       Impact factor: 4.071

  3 in total
  1 in total

1.  Opportunities for Fluorochlorozirconate and Other Glass-Ceramic Detectors in Medical Imaging Devices.

Authors:  Jacqueline A Johnson; Russell L Leonard; A R Lubinsky; Stefan Schweizer
Journal:  J Biomed Technol Res       Date:  2015-06-25
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.