Literature DB >> 7760701

Continuous update with random encoding (CURE): a new strategy for dynamic imaging.

T Parrish1, X Hu.   

Abstract

Although dynamic imaging is presently used for various applications, it is still limited by the temporal resolution. In this paper, we present a new technique that uses a random phase-encoding strategy to facilitate faster and smoother update of images and to improve the temporal resolution in dynamic studies. The technique was implemented on a conventional clinical scanner and demonstrated with various in vivo studies. Technical details, simulations, and experimental results are described. Images from experimental studies indicate that the new technique is robust in generating dynamic images and can be potentially utilized for clinical applications.

Mesh:

Year:  1995        PMID: 7760701     DOI: 10.1002/mrm.1910330307

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Increasing temporal resolution of DSC perfusion MRI using the analytic image concept.

Authors:  Josiane Yankam Njiwa; David Ratering; Christof Baltes; Markus Rudin
Journal:  MAGMA       Date:  2010-08-07       Impact factor: 2.310

2.  A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

Authors:  Luminita A Tudorica; Karen Y Oh; Nicole Roy; Mark D Kettler; Yiyi Chen; Stephanie L Hemmingson; Aneela Afzal; John W Grinstead; Gerhard Laub; Xin Li; Wei Huang
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

3.  Fast four-dimensional coronary MR angiography with k-t GRAPPA.

Authors:  Peng Lai; Feng Huang; Andrew C Larson; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-03       Impact factor: 4.813

4.  3D time-resolved MR angiography (MRA) of the carotid arteries with time-resolved imaging with stochastic trajectories: comparison with 3D contrast-enhanced Bolus-Chase MRA and 3D time-of-flight MRA.

Authors:  R P Lim; M Shapiro; E Y Wang; M Law; J S Babb; L E Rueff; J S Jacob; S Kim; R H Carson; T P Mulholland; G Laub; E M Hecht
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

5.  Sampling strategies for subsampled segmented EPI PRF thermometry in MR guided high intensity focused ultrasound.

Authors:  Henrik Odéen; Nick Todd; Mahamadou Diakite; Emilee Minalga; Allison Payne; Dennis L Parker
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Measurement of murine kidney functional biomarkers using DCE-MRI: A multi-slice TRICKS technique and semi-automated image processing algorithm.

Authors:  Kai Jiang; Hui Tang; Prasanna K Mishra; Slobodan I Macura; Lilach O Lerman
Journal:  Magn Reson Imaging       Date:  2019-08-20       Impact factor: 2.546

7.  Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

Authors:  Ting Song; Andrew F Laine; Qun Chen; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Gerhard Laub; Randall Kroeker; Vivian S Lee
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

8.  Controlled experimental study depicting moving objects in view-shared time-resolved 3D MRA.

Authors:  Petrice M Mostardi; Clifton R Haider; Phillip J Rossman; Eric A Borisch; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

9.  Technical innovation in dynamic contrast-enhanced magnetic resonance imaging of musculoskeletal tumors: an MR angiographic sequence using a sparse k-space sampling strategy.

Authors:  Laura M Fayad; Charles Mugera; Theodoros Soldatos; Aaron Flammang; Filippo del Grande
Journal:  Skeletal Radiol       Date:  2013-04-05       Impact factor: 2.199

10.  Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI.

Authors:  Nilesh N Mistry; James Pollaro; Jiayu Song; Ming De Lin; G Allan Johnson
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.