Literature DB >> 18228577

Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI.

Nilesh N Mistry1, James Pollaro, Jiayu Song, Ming De Lin, G Allan Johnson.   

Abstract

With the development of various models of pulmonary disease, there is tremendous interest in quantitative regional assessment of pulmonary function. While ventilation imaging has been addressed to a certain extent, perfusion imaging for small animals has not kept pace. In humans and large animals perfusion can be assessed using dynamic contrast-enhanced (DCE) MRI with a single bolus injection of a gadolinium (Gd)-based contrast agent. But the method developed for the clinic cannot be translated directly to image the rodent due to the combined requirements of higher spatial and temporal resolution. This work describes a novel image acquisition technique staggered over multiple, repeatable bolus injections of contrast agent using an automated microinjector, synchronized with image acquisition to achieve dynamic first-pass contrast enhancement in the rat lung. This allows dynamic first-pass imaging that can be used to quantify pulmonary perfusion. Further improvements are made in the spatial and temporal resolution by combining the multiple injection acquisition method with Interleaved Radial Imaging and "Sliding window-keyhole" reconstruction (IRIS). The results demonstrate a simultaneous increase in spatial resolution (<200 mum) and temporal resolution (<200 ms) over previous methods, with a limited loss in signal-to-noise-ratio. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18228577      PMCID: PMC2738602          DOI: 10.1002/mrm.21353

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  37 in total

1.  Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging.

Authors:  K K Vigen; D C Peters; T M Grist; W F Block; C A Mistretta
Journal:  Magn Reson Med       Date:  2000-02       Impact factor: 4.668

2.  Registered (1)H and (3)He magnetic resonance microscopy of the lung.

Authors:  G A Johnson; G P Cofer; L W Hedlund; R R Maronpot; S A Suddarth
Journal:  Magn Reson Med       Date:  2001-03       Impact factor: 4.668

3.  Simultaneous acquisition of multiple resolution images for dynamic contrast enhanced imaging of the breast.

Authors:  H K Song; L Dougherty; M D Schnall
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  Perfusion characteristics of radiation-injured lung on Gd-DTPA-enhanced dynamic magnetic resonance imaging.

Authors:  Nobuhiko Ogasawara; Kazuyoshi Suga; Yuichi Karino; Naofumi Matsunaga
Journal:  Invest Radiol       Date:  2002-08       Impact factor: 6.016

Review 5.  Recent advances in imaging the lungs of intact small animals.

Authors:  Daniel P Schuster; Attila Kovacs; Joel Garbow; David Piwnica-Worms
Journal:  Am J Respir Cell Mol Biol       Date:  2004-02       Impact factor: 6.914

6.  Capillary recruitment and transit time in the rat lung.

Authors:  R G Presson; T M Todoran; B J De Witt; I F McMurtry; W W Wagner
Journal:  J Appl Physiol (1985)       Date:  1997-08

7.  Pulmonary prostacyclin synthase overexpression in transgenic mice protects against development of hypoxic pulmonary hypertension.

Authors:  M W Geraci; B Gao; D C Shepherd; M D Moore; J Y Westcott; K A Fagan; L A Alger; R M Tuder; N F Voelkel
Journal:  J Clin Invest       Date:  1999-06       Impact factor: 14.808

8.  A combined 1H perfusion/3He ventilation NMR study in rat lungs.

Authors:  Y Crémillieux; Y Berthezène; H Humblot; M Viallon; E Canet; M Bourgeois; T Albert; W Heil; A Briguet
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

9.  Pulmonary cytochrome P-450 2J4 is reduced in a rat model of acute Pseudomonas pneumonia.

Authors:  Asma Yaghi; J Alyce Bradbury; Darryl C Zeldin; Sanjay Mehta; John R Bend; David G McCormack
Journal:  Am J Physiol Lung Cell Mol Physiol       Date:  2003-07-25       Impact factor: 5.464

10.  Blood volume in the rat.

Authors:  H B Lee; M D Blaufox
Journal:  J Nucl Med       Date:  1985-01       Impact factor: 10.057

View more
  12 in total

Review 1.  Applications of imaging technology in radiation research.

Authors:  MingDe Lin; Edward F Jackson
Journal:  Radiat Res       Date:  2012-03-08       Impact factor: 2.841

2.  Lung perfusion imaging in small animals using 4D micro-CT at heartbeat temporal resolution.

Authors:  Cristian T Badea; Samuel M Johnston; Ergys Subashi; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Med Phys       Date:  2010-01       Impact factor: 4.071

3.  A high-precision contrast injector for small animal x-ray digital subtraction angiography.

Authors:  Ming de Lin; Lutao Ning; Cristian T Badea; Nilesh N Mistry; Yi Qi; G Allan Johnson
Journal:  IEEE Trans Biomed Eng       Date:  2008-03       Impact factor: 4.538

4.  In vivo imaging of the progression of acute lung injury using hyperpolarized [1-13 C] pyruvate.

Authors:  Mehrdad Pourfathi; Yi Xin; Stephen J Kadlecek; Maurizio F Cereda; Harrilla Profka; Hooman Hamedani; Sarmad M Siddiqui; Kai Ruppert; Nicholas A Drachman; Jennia N Rajaei; Rahim R Rizi
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

5.  Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography.

Authors:  MingDe Lin; Craig T Marshall; Yi Qi; Samuel M Johnston; Cristian T Badea; Claude A Piantadosi; G Allan Johnson
Journal:  Med Phys       Date:  2009-11       Impact factor: 4.071

6.  Ventilation/perfusion imaging in a rat model of airway obstruction.

Authors:  Nilesh N Mistry; Yi Qi; Laurence W Hedlund; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

7.  Improving temporal resolution of pulmonary perfusion imaging in rats using the partially separable functions model.

Authors:  Cornelius Brinegar; Sarah S Schmitter; Nilesh N Mistry; G Allan Johnson; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

8.  Phenylephrine-modulated cardiopulmonary blood flow measured with use of X-ray digital subtraction angiography.

Authors:  MingDe Lin; Yi Qi; Antonia F Chen; Cristian T Badea; G Allan Johnson
Journal:  J Pharmacol Toxicol Methods       Date:  2011-08-07       Impact factor: 1.950

9.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

10.  Contrast-enhanced magnetic resonance imaging with a novel nano-size contrast agent for the clinical diagnosis of patients with lung cancer.

Authors:  Jianwei Gao; Lei Li; Xia Liu; Rui Guo; Bin Zhao
Journal:  Exp Ther Med       Date:  2018-04-30       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.