Literature DB >> 2046514

Volume imaging with MR phased arrays.

C E Hayes1, N Hattes, P B Roemer.   

Abstract

A volume MR phased array was constructed with two coils placed anteriorly and two coils posteriorly. Data acquired simultaneously from the four coils on a phantom were combined into a single image having a signal-to-noise ratio 80% better than that from the body coil. Additional comparisons of the four-coil phased array with a two-coil phased array and a Helmholtz pair having the same overall dimensions show how variations of signal amplitude and phase in the individual coils affect the composite SNR. Images of the male and female pelvis demonstrate how the improved SNR can be used to reduce the number of excitations, decrease the field of view, increase the echo time, or reduce the slice thickness.

Mesh:

Year:  1991        PMID: 2046514     DOI: 10.1002/mrm.1910180206

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  31 in total

1.  Multiple channel phased arrays for echo planar imaging.

Authors:  G X Shen; J Wu; F E Boada
Journal:  MAGMA       Date:  2000-12       Impact factor: 2.310

2.  Determination of appropriate RF blocking impedance for MRI surface coils and arrays.

Authors:  A Kocharian; P J Rossman; T C Hulshizer; J P Felmlee; S J Riederer
Journal:  MAGMA       Date:  2000-06       Impact factor: 2.310

3.  High-sensitivity coil array for head and neck imaging: technical note.

Authors:  R G Henry; N J Fischbein; W P Dillon; D B Vigneron; S J Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2001 Nov-Dec       Impact factor: 3.825

4.  A volume adjustable four-coil phased array for high resolution MR imaging of the hip.

Authors:  W E Kwok; K K Lo; G Seo; S M Totterman
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

5.  Optimization of the number of selectable channels for spine phased array coils for transverse imaging.

Authors:  Susumu Moriya; Yukio Miki; Tsuneo Yokobayashi; Akira Yamamoto; Mitsunori Kanagaki; Yoshiaki Komori; Koji Fujimoto; Mitsunori Ishikawa
Journal:  Jpn J Radiol       Date:  2011-04-26       Impact factor: 2.374

6.  Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

Authors:  Daniel K Sodickson; Christopher J Hardy; Yudong Zhu; Randy O Giaquinto; Patrick Gross; Gontran Kenwood; Thoralf Niendorf; Hubert Lejay; Charles A McKenzie; Michael A Ohliger; Aaron K Grant; Neil M Rofsky
Journal:  Acad Radiol       Date:  2005-05       Impact factor: 3.173

7.  How long to scan? The relationship between fMRI temporal signal to noise ratio and necessary scan duration.

Authors:  Kevin Murphy; Jerzy Bodurka; Peter A Bandettini
Journal:  Neuroimage       Date:  2006-11-22       Impact factor: 6.556

8.  The MR Cap: A single-sided MRI system designed for potential point-of-care limited field-of-view brain imaging.

Authors:  Patrick C McDaniel; Clarissa Zimmerman Cooley; Jason P Stockmann; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2019-06-23       Impact factor: 4.668

9.  Brain imaging with improved acceleration and SNR at 7 Tesla obtained with 64-channel receive array.

Authors:  Kamil Uğurbil; Edward Auerbach; Steen Moeller; Andrea Grant; Xiaoping Wu; Pierre-Francois Van de Moortele; Cheryl Olman; Lance DelaBarre; Scott Schillak; Jerahmie Radder; Russell Lagore; Gregor Adriany
Journal:  Magn Reson Med       Date:  2019-02-25       Impact factor: 4.668

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.