Literature DB >> 23204945

INTERCOMPARISON OF PERFORMANCE OF RF COIL GEOMETRIES FOR HIGH FIELD MOUSE CARDIAC MRI.

Christakis Constantinides1, S Angeli, S Gkagkarellis, G Cofer.   

Abstract

Multi-turn spiral surface coils are constructed in flat and cylindrical arrangements and used for high field (7.1 T) mouse cardiac MRI. Their electrical and imaging performances, based on experimental measurements, simulations, and MRI experiments in free space, and under phantom, and animal loading conditions, are compared with a commercially available birdcage coil. Results show that the four-turn cylindrical spiral coil exhibits improved relative SNR (rSNR) performance to the flat coil counterpart, and compares fairly well with a commercially available birdcage coil. Phantom experiments indicate a 50% improvement in the SNR for penetration depths ≤ 6.1 mm from the coil surface compared to the birdcage coil, and an increased penetration depth at the half-maximum field response of 8 mm in the 4-spiral cylindrical coil case, in contrast to 2.9 mm in the flat 4-turn spiral case. Quantitative comparison of the performance of the two spiral coil geometries in anterior, lateral, inferior, and septal regions of the murine heart yield maximum mean percentage rSNR increases of the order of 27-167% in vivo post-mortem (cylindrical compared to flat coil). The commercially available birdcage outperforms the cylindrical spiral coil in rSNR by a factor of 3-5 times. The comprehensive approach and methodology adopted to accurately design, simulate, implement, and test radiofrequency coils of any geometry and type, under any loading conditions, can be generalized for any application of high field mouse cardiac MRI.

Entities:  

Year:  2011        PMID: 23204945      PMCID: PMC3508705          DOI: 10.1002/cmr.a.20225

Source DB:  PubMed          Journal:  Concepts Magn Reson Part A Bridg Educ Res        ISSN: 1546-6086            Impact factor:   0.481


  32 in total

1.  Three-dimensional triple-quantum-filtered (23)Na imaging of in vivo human brain.

Authors:  I Hancu; F E Boada; G X Shen
Journal:  Magn Reson Med       Date:  1999-12       Impact factor: 4.668

2.  Human cardiac imaging at 3 T using phased array coils.

Authors:  R Noeske; F Seifert; K H Rhein; H Rinneberg
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

3.  Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.

Authors:  Tamer S Ibrahim; Chad Mitchell; Petra Schmalbrock; Robert Lee; Donald W Chakeres
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

4.  Multiple-mouse MRI with multiple arrays of receive coils.

Authors:  Marc S Ramirez; Emilio Esparza-Coss; James A Bankson
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

5.  Cardiovascular phenotyping of the mouse heart using a 4D radial acquisition and liposomal Gd-DTPA-BMA.

Authors:  Elizabeth Bucholz; Ketan Ghaghada; Yi Qi; Srinivasan Mukundan; Howard A Rockman; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

6.  Mouse MRI using phased-array coils.

Authors:  Daniel Gareis; Tobias Wichmann; Titus Lanz; Gerd Melkus; Michael Horn; Peter M Jakob
Journal:  NMR Biomed       Date:  2007-05       Impact factor: 4.044

7.  4D retrospective black blood trueFISP imaging of mouse heart.

Authors:  Sylvain Miraux; Guillaume Calmettes; Philippe Massot; William Lefrançois; Elodie Parzy; Bernard Muller; Laurent M Arsac; Véronique Deschodt-Arsac; Jean-Michel Franconi; Philippe Diolez; Eric Thiaudière
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

8.  Angiotensin II type 2 receptor overexpression preserves left ventricular function after myocardial infarction.

Authors:  Zequan Yang; Christina M Bove; Brent A French; Frederick H Epstein; Stuart S Berr; Joseph M DiMaria; Jennifer J Gibson; Robert M Carey; Christopher M Kramer
Journal:  Circulation       Date:  2002-07-02       Impact factor: 29.690

9.  A high-throughput eight-channel probe head for murine MRI at 9.4 T.

Authors:  Titus Lanz; Matthias Müller; Hannah Barnes; Stefan Neubauer; Jürgen E Schneider
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

10.  Fast, high-resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system.

Authors:  Jürgen E Schneider; Paul J Cassidy; Craig Lygate; Damian J Tyler; Frank Wiesmann; Stuart M Grieve; Karen Hulbert; Kieran Clarke; Stefan Neubauer
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

View more
  2 in total

1.  Repeatability of B1 + inhomogeneity correction of volumetric (3D) glutamate CEST via High-permittivity dielectric padding at 7T.

Authors:  Paul S Jacobs; Blake Benyard; Abigail Cember; Ravi Prakash Reddy Nanga; Quy Cao; M Dylan Tisdall; Neil Wilson; Sandhitsu Das; Kathryn A Davis; John Detre; David Roalf; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2022-08-15       Impact factor: 3.737

2.  Bridging photochemistry and photomechanics with NMR crystallography: the molecular basis for the macroscopic expansion of an anthracene ester nanorod.

Authors:  Kevin R Chalek; Xinning Dong; Fei Tong; Ryan A Kudla; Lingyan Zhu; Adam D Gill; Wenwen Xu; Chen Yang; Joshua D Hartman; Alviclér Magalhães; Rabih O Al-Kaysi; Ryan C Hayward; Richard J Hooley; Gregory J O Beran; Christopher J Bardeen; Leonard J Mueller
Journal:  Chem Sci       Date:  2020-10-30       Impact factor: 9.825

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.