Literature DB >> 21243106

A 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments.

Mark Haig Khachaturian1.   

Abstract

Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatomical accuracy (i.e., reduction of EPI distortions) can be achieved using parallel imaging. The major challenges associated with constructing phased array coils for monkeys are the variation in head size and space constraints. Here, we apply phased array technology to a 4-channel phased array coil capable of improving the resolution and image quality of full brain awake monkey fMRI and diffusion MRI experiments. The phased array coil is that can adapt to different rhesus monkey head sizes (ages 4-8) and fits in the limited space provided by monkey stereotactic equipment and provides SNR gains in primary visual cortex and anatomical accuracy in conjunction with parallel imaging and improves resolution in fMRI experiments by a factor of 2 (1.25 mm to 1.0 mm isotropic) and diffusion MRI experiments by a factor of 4 (1.5 mm to 0.9 mm isotropic).

Entities:  

Year:  2010        PMID: 21243106      PMCID: PMC3019607          DOI: 10.4236/jbise.2010.311141

Source DB:  PubMed          Journal:  J Biomed Sci Eng        ISSN: 1937-6871


  28 in total

1.  Visual motion processing investigated using contrast agent-enhanced fMRI in awake behaving monkeys.

Authors:  W Vanduffel; D Fize; J B Mandeville; K Nelissen; P Van Hecke; B R Rosen; R B Tootell; G A Orban
Journal:  Neuron       Date:  2001-11-20       Impact factor: 17.173

2.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

3.  SENSE-DTI at 3 T.

Authors:  T Jaermann; G Crelier; K P Pruessmann; X Golay; T Netsch; A M C van Muiswinkel; S Mori; P C M van Zijl; A Valavanis; S Kollias; P Boesiger
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

4.  Influence of SENSE on image properties in high-resolution single-shot echo-planar DTI.

Authors:  T Jaermann; K P Pruessmann; A Valavanis; S Kollias; P Boesiger
Journal:  Magn Reson Med       Date:  2006-02       Impact factor: 4.668

5.  Analysis of brain white matter via fiber tract modeling.

Authors:  Guido Gerig; Sylvain Gouttard; Isabelle Corouge
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

6.  A phased array coil for human cardiac imaging.

Authors:  C D Constantinides; C R Westgate; W G O'Dell; E A Zerhouni; E R McVeigh
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

7.  Surface-coil T1 images.

Authors:  C J Hardy; W A Edelstein; O M Mueller
Journal:  Magn Reson Med       Date:  1986-12       Impact factor: 4.668

8.  Focal reversible deactivation of cerebral metabolism affects water diffusion.

Authors:  Mark H Khachaturian; John Arsenault; Leeland B Ekstrom; David S Tuch; Wim Vanduffel
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

9.  Bottom-up dependent gating of frontal signals in early visual cortex.

Authors:  Leeland B Ekstrom; Pieter R Roelfsema; John T Arsenault; Giorgio Bonmassar; Wim Vanduffel
Journal:  Science       Date:  2008-07-18       Impact factor: 47.728

10.  Abnormal brain connectivity in first-episode psychosis: a diffusion MRI tractography study of the corpus callosum.

Authors:  Gary Price; Mara Cercignani; Geoffrey J M Parker; Daniel R Altmann; Thomas R E Barnes; Gareth J Barker; Eileen M Joyce; Maria A Ron
Journal:  Neuroimage       Date:  2006-12-23       Impact factor: 6.556

View more
  5 in total

1.  An implanted 8-channel array coil for high-resolution macaque MRI at 3T.

Authors:  T Janssens; B Keil; R Farivar; J A McNab; J R Polimeni; A Gerits; J T Arsenault; L L Wald; W Vanduffel
Journal:  Neuroimage       Date:  2012-05-18       Impact factor: 6.556

2.  Quadrature RF Coil for In Vivo Brain MRI of a Macaque Monkey in a Stereotaxic Head Frame.

Authors:  Colin A Roopnariane; Yeun-Chul Ryu; Mohammad-Reza Tofighi; Patti A Miller; Sukhoon Oh; Jianli Wang; Bu Sik Park; Lukas Ansel; Christopher A Lieu; Thyagarajan Subramanian; Qing X Yang; Christopher M Collins
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2012-02-18       Impact factor: 1.176

3.  An embedded four-channel receive-only RF coil array for fMRI experiments of the somatosensory pathway in conscious awake marmosets.

Authors:  Daniel Papoti; Cecil Chern-Chyi Yen; Julie B Mackel; Hellmut Merkle; Afonso C Silva
Journal:  NMR Biomed       Date:  2013-05-22       Impact factor: 4.044

4.  Towards HCP-Style macaque connectomes: 24-Channel 3T multi-array coil, MRI sequences and preprocessing.

Authors:  Joonas A Autio; Matthew F Glasser; Takayuki Ose; Chad J Donahue; Matteo Bastiani; Masahiro Ohno; Yoshihiko Kawabata; Yuta Urushibata; Katsutoshi Murata; Kantaro Nishigori; Masataka Yamaguchi; Yuki Hori; Atsushi Yoshida; Yasuhiro Go; Timothy S Coalson; Saad Jbabdi; Stamatios N Sotiropoulos; Henry Kennedy; Stephen Smith; David C Van Essen; Takuya Hayashi
Journal:  Neuroimage       Date:  2020-04-08       Impact factor: 6.556

5.  Characteristics of diffusion-tensor imaging for healthy adult rhesus monkey brains.

Authors:  Xinxiang Zhao; Jun Pu; Yaodong Fan; Xiaoqun Niu; Danping Yu; Yanglin Zhang
Journal:  Neural Regen Res       Date:  2013-11-05       Impact factor: 5.135

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.