Literature DB >> 7673902

Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty.

R Nagamine1, S E White, D S McCarthy, L A Whiteside.   

Abstract

Excessive external rotation of the femoral component can cause an abnormally tight popliteus tendon complex, which induces loss of rotational laxity of the knee in the late phase of knee flexion after total knee arthroplasty. This study evaluated the effect of popliteus tendon release on rotational and varus-valgus laxity of implanted knees with an excessively externally rotated femoral component. Rotational and varus-valgus laxity was measured with a knee kinematics testing device before and after total knee arthroplasty. External rotational positions of the femoral component of 5 degrees and 8 degrees were compared, and the effects of popliteus tendon release on rotational and varus-valgus laxity were evaluated. To further investigate this question, the effect of a conforming articular design was compared with that of a flat tibial surface. External rotational position of 5 degrees did not change rotational or varus-valgus laxity of the knee. With an 8 degrees external rotational position, however, external rotational laxity significantly decreased in knees with a conforming surface at angles of 30 degrees, 45 degrees, 60 degrees, and 90 degrees. After popliteus tendon release, external rotational laxity significantly improved at 90 degrees flexion and was identical to that of the normal knee. Internal rotational range was similar before and after popliteus tendon release. Popliteus tendon release did not affect the varus-valgus laxity (stability) with either articular surface.

Entities:  

Mesh:

Year:  1995        PMID: 7673902     DOI: 10.1016/s0883-5403(05)80172-x

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  11 in total

1.  The influence of tibial slope on maximal flexion after total knee arthroplasty.

Authors:  J Bellemans; F Robijns; J Duerinckx; S Banks; H Vandenneucker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-26       Impact factor: 4.342

2.  Determining femoral component position using CAS and measured resection.

Authors:  James Benjamin
Journal:  Clin Orthop Relat Res       Date:  2008-08-15       Impact factor: 4.176

3.  Is a femoral component applicator useful in total knee replacement?

Authors:  Adnan A Faraj; Prashant Boda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-09       Impact factor: 4.342

4.  Isolated popliteus tendon injury does not lead to abnormal laxity in posterior-stabilised total knee arthroplasty.

Authors:  K M Ghosh; N Hunt; A Blain; K K Athwal; L Longstaff; A A Amis; S Rushton; D J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-01       Impact factor: 4.342

5.  Role of preoperative calculation of condylar twist angle (CTA) by CT scan in optimizing femoral component rotation during TKA.

Authors:  D Sharma; A Shukla; K Kumar
Journal:  Musculoskelet Surg       Date:  2017-03-02

6.  Moderate clinical improvement after revision arthroplasty of the severely stiff knee.

Authors:  P J C Heesterbeek; J H M Goosen; J J P Schimmel; K C Defoort; G G van Hellemondt; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-07-28       Impact factor: 4.342

7.  Inter- and intraobserver reliability of two-dimensional CT scan for total knee arthroplasty component malrotation.

Authors:  Beau Konigsberg; Ryan Hess; Curtis Hartman; Lynette Smith; Kevin L Garvin
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

8.  Femoral rotation influences dynamic alignment of the lower extremity in total knee arthroplasty.

Authors:  Zhongyuan Zhao; Weiguang Wang; Shijun Wang; Limin Jiang; Shudong Zhang; Yuchi Zhao
Journal:  Int Orthop       Date:  2014-08-10       Impact factor: 3.075

9.  Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty.

Authors:  Liliana Savin; Paul Botez; Dan Mihailescu; Vlad Predescu; Carmen Grierosu
Journal:  Int Orthop       Date:  2016-01-23       Impact factor: 3.075

10.  Iatrogenic popliteus tendon injury during total knee arthroplasty results in decreased knee function two to three years postoperatively.

Authors:  Vito de Simone; Guillaume Demey; Robert A Magnussen; Sebastien Lustig; Elvire Servien; Philippe Neyret
Journal:  Int Orthop       Date:  2012-08-01       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.