Literature DB >> 28251582

Role of preoperative calculation of condylar twist angle (CTA) by CT scan in optimizing femoral component rotation during TKA.

D Sharma1,2, A Shukla3, K Kumar4.   

Abstract

BACKGROUND: A perfect rotational alignment could be achieved if the implant rotation is individualized for each knee before operation. The anatomic transepicondylar axis (aTEA) is a standard reference for setting the femoral component rotation. Intraoperative localization of aTEA is difficult. However, aTEA could be readily identified on preoperative CT scans, and condylar twist angle (CTA) could be determined preoperatively. The femoral component can subsequently be implanted according to CTA. Therefore, perfect intraoperative rotational alignment can be easily achieved. The aim of the study was to evaluate the role of preoperative calculation of CTA by CT scan in optimizing femoral component rotation during TKA.
MATERIALS AND METHODS: We analyzed fifty-three total knee arthroplasty in 36 primary osteoarthritis patients, aged 49-78 years. CTA was measured on preoperative CT scan. Intraoperative equal magnitude of external rotation was set so that the femoral cut was parallel to aTEA. Postoperative CT scan was done to confirm the femoral component rotation.
RESULTS: Postoperatively, femoral component was parallel to aTEA with a mean error of 0.77°. In 34 knees (64.15%), surgical transepicondylar axis (sTEA) could also be determined; average angle between sTEA and aTEA was 4.65°. Femoral component in these knees was found to be parallel or externally rotated in relation to sTEA (mean 4.22°).
CONCLUSION: Preoperative calculation of CTA by CT scan helps to optimize the femoral component rotation during TKA.

Entities:  

Keywords:  CT scan; Condylar twist angle; Femoral rotation; TKA; Transepicondylar axis

Mesh:

Year:  2017        PMID: 28251582     DOI: 10.1007/s12306-017-0466-z

Source DB:  PubMed          Journal:  Musculoskelet Surg        ISSN: 2035-5114


  10 in total

1.  Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri
Journal:  Acta Orthop Scand       Date:  2004-02

2.  Early revision for isolated internal malrotation of the femoral component in total knee arthroplasty.

Authors:  Martin Pietsch; Siegfried Hofmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-10       Impact factor: 4.342

3.  The functional flexion-extension axis of the knee corresponds to the surgical epicondylar axis: in vivo analysis using a biplanar image-matching technique.

Authors:  Taiyo Asano; Masao Akagi; Takashi Nakamura
Journal:  J Arthroplasty       Date:  2005-12       Impact factor: 4.757

4.  A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation.

Authors:  Georg Matziolis; Doerte Krocker; Ulrike Weiss; Stephan Tohtz; Carsten Perka
Journal:  J Bone Joint Surg Am       Date:  2007-02       Impact factor: 5.284

5.  Rotational position of femoral and tibial components in TKA using the femoral transepicondylar axis.

Authors:  Paolo Aglietti; Lorenzo Sensi; Pierluigi Cuomo; Antonio Ciardullo
Journal:  Clin Orthop Relat Res       Date:  2008-09-30       Impact factor: 4.176

6.  Optimizing femoral component rotation in total knee arthroplasty.

Authors:  M C Miller; R A Berger; A J Petrella; A Karmas; H E Rubash
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

7.  Computed tomography measurement of the surgical and clinical transepicondylar axis of the distal femur in osteoarthritic knees.

Authors:  N Yoshino; S Takai; Y Ohtsuki; Y Hirasawa
Journal:  J Arthroplasty       Date:  2001-06       Impact factor: 4.757

8.  Femoral component rotation and arthrofibrosis following mobile-bearing total knee arthroplasty.

Authors:  J G Boldt; J B Stiehl; J Hodler; M Zanetti; U Munzinger
Journal:  Int Orthop       Date:  2006-03-07       Impact factor: 3.075

9.  Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty.

Authors:  R Nagamine; S E White; D S McCarthy; L A Whiteside
Journal:  J Arthroplasty       Date:  1995-06       Impact factor: 4.757

10.  Distal femoral rotational axes in Indian knees.

Authors:  Arun B Mullaji; Amit K Sharma; Satyajit V Marawar; Anirudh F Kohli; Dharmendra P Singh
Journal:  J Orthop Surg (Hong Kong)       Date:  2009-08       Impact factor: 1.118

  10 in total
  2 in total

1.  Accuracy of 2D CT-Based Measurements of Rotational Alignment of the Femoral Component for Total Knee Arthroplasty.

Authors:  Jun Young Park; Hyuck Min Kwon; Byung Woo Cho; Woo Suk Lee; Ick Hwan Yang; Kwan Kyu Park
Journal:  Yonsei Med J       Date:  2021-05       Impact factor: 2.759

2.  Satisfactory mid- to long-term outcomes of TKA aligned using conventional instrumentation for flexion gap balancing with minimal soft tissue release.

Authors:  Michel Bercovy; Luc Kerboull; Jacobus H Müller; Mo Saffarini; Frederic Sailhan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-11-11       Impact factor: 4.114

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.