Literature DB >> 25106671

Femoral rotation influences dynamic alignment of the lower extremity in total knee arthroplasty.

Zhongyuan Zhao1, Weiguang Wang, Shijun Wang, Limin Jiang, Shudong Zhang, Yuchi Zhao.   

Abstract

PURPOSE: Besides the long-leg standing X-ray film focusing on static standing mechanical alignment of the lower extremity, dynamic alignment from full extension to 90° flexion after total knee arthroplasty (TKA) is rarely mentioned. Computer-assisted surgical technology enables surgeons to measure and assess knee behaviour during surgery. This study was designed to analyse the influences of femoral rotation on dynamic alignment of the lower extremity in TKA.
METHODS: Seventy-six consecutive patients with end-stage knee osteoarthritis were enrolled. External rotation osteotomy of the distal femur during TKA was completed according to the pre-operative external rotation angle (ERA), intra-operative transepicondylar axis (TEA) and anteroposterior (AP) line. Passive dynamic alignment of the lower extremity during knee flexion was recorded. The variation trend of hip-knee-ankle (HKA) alignment and the influences of femoral external rotation osteotomy were analysed.
RESULTS: Postoperative deviation of HKA alignment from 0° to 90° flexion was associated with the rotational alignment of the femoral component (r = -0.769, p < 0.001). Variation trend of HKA alignment during knee flexion tended to be varus, valgus and neutral according to the selected angle of external rotation osteotomy of the distal femur.
CONCLUSION: External rotation osteotomy of the distal femur played a crucial role in determining dynamic HKA alignment in TKA.

Entities:  

Mesh:

Year:  2014        PMID: 25106671     DOI: 10.1007/s00264-014-2484-x

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  26 in total

1.  A comparison of 4 intraoperative methods to determine femoral component rotation during total knee arthroplasty.

Authors:  C W Olcott; R D Scott
Journal:  J Arthroplasty       Date:  2000-01       Impact factor: 4.757

2.  Perfect balance in total knee arthroplasty: the elusive compromise.

Authors:  M J Winemaker
Journal:  J Arthroplasty       Date:  2002-01       Impact factor: 4.757

3.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

4.  Low reproducibility of the intra-operative measurement of the transepicondylar axis during total knee replacement.

Authors:  Jean-Yves Jenny; Cyril Boeri
Journal:  Acta Orthop Scand       Date:  2004-02

5.  Computer-assisted total knee arthroplasty: comparative results in a preliminary series of 72 cases.

Authors:  David Zorman; Philippe Etuin; Harold Jennart; Dominique Scipioni; Stéphane Devos
Journal:  Acta Orthop Belg       Date:  2005-12       Impact factor: 0.500

6.  Computer-assisted dynamic total knee arthroplasty using Whiteside's line for alignment.

Authors:  Frederic Picard; Alberto Gregori; Fraser Dean; Audrey Mennessier; John Dillon
Journal:  Orthopedics       Date:  2006-10       Impact factor: 1.390

7.  Coronal alignment after total knee replacement.

Authors:  R S Jeffery; R W Morris; R A Denham
Journal:  J Bone Joint Surg Br       Date:  1991-09

8.  The effects of axial rotational alignment of the femoral component on knee stability and patellar tracking in total knee arthroplasty demonstrated on autopsy specimens.

Authors:  Y S Anouchi; L A Whiteside; A D Kaiser; M T Milliano
Journal:  Clin Orthop Relat Res       Date:  1993-02       Impact factor: 4.176

9.  [Distal femoral torsion: comparison of CT scan and intra operative navigation measurements during total knee arthroplasty. A report of 70 cases].

Authors:  B Galaud; P Beaufils; M Michaut; P Abadie; L Fallet; P Boisrenoult
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2008-07-09

10.  Effect of rotational malposition of the femoral component on knee stability kinematics after total knee arthroplasty.

Authors:  R Nagamine; S E White; D S McCarthy; L A Whiteside
Journal:  J Arthroplasty       Date:  1995-06       Impact factor: 4.757

View more
  7 in total

1.  Using the anatomical tibial axis for total knee arthroplasty alignment may lead to an internal rotation error.

Authors:  Csaba Forster-Horvath; Valerie Kremo; Magdalena Müller-Gerbl; Andrej Maria Nowakowski
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

2.  Intra-operative gaps affect outcome and postoperative kinematics in vivo following cruciate-retaining total knee arthroplasty.

Authors:  Eisaku Fujimoto; Yoshiaki Sasashige; Tetsuya Tomita; Hirofumi Sasaki; Yoriko Touten; Yuusuke Fujiwara; Mitsuo Ochi
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

3.  Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

Authors:  José Figueroa; Juan Pablo Guarachi; José Matas; Magnus Arnander; Mario Orrego
Journal:  Int Orthop       Date:  2015-07-25       Impact factor: 3.075

4.  Coronal and axial alignment relationship in Caucasian patients with osteoarthritis of the knee.

Authors:  Vicente J León-Muñoz; Silvio Manca; Mirian López-López; Francisco Martínez-Martínez; Fernando Santonja-Medina
Journal:  Sci Rep       Date:  2021-04-09       Impact factor: 4.379

5.  Improved femoral component rotation in advanced genu valgum deformity using computer-assisted measured resection total knee arthroplasty.

Authors:  Shih-Jie Lin; Chien-Ying Lee; Kuo-Chin Huang; Kuo-Ti Peng; Tsan-Wen Huang; Mel S Lee; Robert Wen-Wei Hsu; Wun-Jer Shen
Journal:  J Orthop Surg Res       Date:  2015-09-02       Impact factor: 2.359

6.  Relationships between Morphological Changes of Lower Limbs and Gender During Medial Compartment Knee Osteoarthritis.

Authors:  Yang Lu; Zhan-le Zheng; Ji Lv; Rui-Zheng Hao; Yi-Ping Yang; Ying-Ze Zhang
Journal:  Orthop Surg       Date:  2019-10       Impact factor: 2.071

7.  Dynamic deformation of femur during medial compartment knee osteoarthritis.

Authors:  Yang Lu; Zhanle Zheng; Wei Chen; Hongzhi Lv; Ji Lv; Yingze Zhang
Journal:  PLoS One       Date:  2019-12-20       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.